
The document appears to present technical specifications related to a product or system named "HITECH PANEL". The data includes various numerical values associated with units such as UV, KG, and m², suggesting measurements of ultraviolet properties, weight, and surface area respectively.
While the document provides raw numerical data, it lacks explicit context or detailed descriptions of each parameter. For practical application, it is recommended to cross-reference these values with product manuals or technical datasheets to understand their significance fully.
Key considerations include ensuring correct installation angles (e.g., 90°), verifying weight capacities (KG values), and confirming surface area coverage (m²) for project planning.
The document does not include explanatory notes, procedural instructions, or normative references, limiting its standalone usability. Additional documentation is necessary to interpret and apply the data effectively.
HITECH PANEL THE ORIGINAL LIGHTWEIGHT POLYMER ROOF TILES
Open the catalog to page 1Durable, Economical and Practical iSti mmPOLYMERROOF TILE PANELS izodach polymer roof tile panels are produced with its unique high density insulation and reinforcing 4 layers HITECH PANEL
Open the catalog to page 2IZOPLAST PVC-ASA Roof Sheets maintain their pyhsical properties in extreme temperatures ranging between -30°C and and 90°C Izodach products are highly heat and UV resistant thanks to their outstanding acrylic surface layer and the subsequent multilayered polymer compound. UV radiation & sun block barrier
Open the catalog to page 3ACRYLONITRILE STYRENE ACRYLATE (ASA) ASA is an all weather acrylic protection polymer, it acts as a powerful anti - UV & sun ray blocking layer at the top surface of the roof panel. ASA is an abrasion resistant material suitable for all atmospheric conditions. IZODACH insulates against heat and sound. IZODACH polymer panels are Eco-Friendly and 100% recyclable.
Open the catalog to page 4Effective Width : 900 mm Purlin Spacing : 750 mm Lengths : 2 - 8 meters
Open the catalog to page 5Effective Width : 960 mm Purlin Spacing : 660 mm Lengths : 2 - 8 meters
Open the catalog to page 7Thickness : 2.5 - 3.5 mm Width : 885 mm Effective Width : 800 mm Purlin Spacing : 660 mm Lengths : 2 - 8 meters
Open the catalog to page 9Thickness : 2.5 - 3.5 mm Width : 885 mm Effective Width : 800 mm Purlin Spacing : 660 mm Lengths : 2 - 8 meters
Open the catalog to page 10Effective Width : 800 mm Purlin Spacing : 660 mm Lengths : 2 - 8 meters
Open the catalog to page 11TILE PANEL ACCESSORIES ASSEMBLY
Open the catalog to page 13VALLEY DEFLECTOR RIDGE
Open the catalog to page 14Thickness : 2.5 - 3.5 mm Width : 1020 mm Effective Width : 930 mm Purlin Spacing : 320 mm Lengths : Multiple of 320 mm
Open the catalog to page 15OTR ACCESSORIES ONDUMAX TOP RIDGE 960
Open the catalog to page 16Thickness : 1.0 - 3.5 mm Width : 1100 mm Effective Width : 1025 mm Purlin Spacing : 500 - 1000 mm Lengths : 2 - 8 meters
Open the catalog to page 17Effective Width : 820 mm Purlin Spacing : 500 mm Lengths : 2 - 8 meters
Open the catalog to page 20QUADRIMAX - ECOMAX ACCESSORIES POLYSTEP - ECOSTEP ACCESSORIES
Open the catalog to page 21IZOFlK (PDWC) Do not overtighten so that cap closes properly. cause washer seal to PVC Dome Washer Seal With Cap screw with special butterfly wing is recommended (for more info on screw types please see page on bolting & fixing methot)
Open the catalog to page 22IZOWAVE - PRO 930 - 880 - 54ACCESSORIES Effective Width : 880 mm Purlin Spacing : 750 -1000 mm Lengths : 2 - 8 meters
Open the catalog to page 23Solar EnergyClamping Brackets Renewable Energy, using sun power Suitable for IZOWAVE MAX & PRO
Open the catalog to page 25SPLIT TOP RIDGE FOR EASY ANGLE ADJUSTMENT
Open the catalog to page 26Recommended screw grade : G14 (63 mm dia.), with 8 mm Hex screw head Lengths : 75mm, 90mm & 120mm if screws with wings are not available, drill a hole with a diameter of 8.5 mm in the panel
Open the catalog to page 28izoplast Roofing panels need a minimum roof slope to perform as intended. The roof slopes charts as shown above must be strictly abided with. Never below ^ Only the top centerApply Screw at the Peak of the Corrugation 29
Open the catalog to page 29HITECH PANEL
Open the catalog to page 30HITECH PANEL
Open the catalog to page 31IZOLAST HITECH PANEL PLASTIK Dl§ TIC A.§ 1 Qilek Mah. 63138 Sk. No: 3/B-C, Akdeniz zip code: 33020, MERSiN-TURKiYE
Open the catalog to page 32