1. Catalogs
  2. ITALKERO
  3. PRO-Air EPP

PRO-Air EPP

PRO-Air EPP
1 / 12 PagesView full catalog

PRO-Air EPP

Product catalog summary
General Information
The PRO-AIR fan heater features an electronically commutated motor controlled by an external voltage signal (0-10V). This manual is crucial for the device's operation and should be provided to the user.
Application
PRO-AIR heaters are designed for decentralized heating systems in large buildings like industrial and public spaces. They are intended for indoor use where air dustiness does not exceed 0.3 g/m3. Constructed from copper, aluminum, and galvanized steel, they should not be installed in rust-prone environments.
Technical Data
The document outlines specifications for models PRO-AIR 18, 35, 50, and 70, including dimensions, airflow, power supply, current and power consumption, insulation class, acoustic pressure level, heating water temperature, operating pressure, connection size, ambient temperature, and weight.
Heat Capacity Sheet
This section details each model's performance at various inlet and outlet air and water temperatures, including airflow, heat capacity, water flow rate, and pressure drop.
Installation
Fan heaters can be mounted vertically or horizontally, maintaining minimum distances from walls and ceilings. The Pro-Air bracket allows for various mounting positions. Expansion bolts are not included and should be selected based on wall type.
Controls
The fan operation is managed by the M system, adjusting heater efficiency based on room temperature. The VNT20 controller modulates fan airflow from 0-100% depending on temperature differences.
Start-Up and Operation
Guidelines include ensuring stress-free connections, installing vent valves, using shut-off valves, and protecting the system against pressure increases. Before starting, verify electrical connections and system tightness. The device should not operate below 0°C without precautions against freezing, such as using glycol solutions.
Specifications and Safety Instructions
- Do not place objects on the heater or hang items on connecting stubs.
- Periodic inspection is required; switch off immediately if malfunctioning.
- Do not use a damaged device; the manufacturer is not responsible for damages from such use.
- Clean the exchanger carefully to avoid damaging aluminum lamellas.
- Disconnect power during inspection or cleaning.
- If water is drained for a long period, empty exchanger tubes with compressed air.
- Modifications to the unit are prohibited and void the warranty.
Installation Guidelines
- Installation should be stress-free.
- Install vent valves at the highest point of the system.
- Ensure the system allows for device disassembly in case of failure; install a shut-off valve upstream.
- Protect the liquid-containing system from internal pressure exceeding 1.6 MPa.
- Securely hold the connecting stub with a wrench when attaching the exchanger to pipes.
Operation Instructions
- Verify correct motor fan and device connections before electrical connection.
- Ensure supply voltage matches device specifications before connecting to the power grid.
- Check channel temperature connections and system tightness before activation.
- Protect the fan motor's electrical system with a circuit breaker.
- Do not operate the machine without grounding.
- Designed for indoor use above 0°C; risk of liquid freezing below 0°C.
- Use glycol solution or automatic systems to prevent freezing if used below 0°C.
- Periodic checks are necessary; turn off immediately if malfunctioning.
- Do not use damaged devices; the manufacturer is not liable for damages from improper use.
Service and Warranty Terms
- Contact your dealer for warranty terms and limitations.
- Report any operational irregularities to the manufacturer's service department.
- The manufacturer is not responsible for improper use by unauthorized persons or resulting damages.
See more

Catalog excerpts

PRO-Air EPP-1

FAN HEATER TECHNICAL DOCUMENTATION OPERATION MANUAL

 Open the catalog to page 1
PRO-Air EPP-2

Thank you for purchasing the PRO-AIR fan heater. This operation manual has been issued by the ITALKERO company. The manufacturer reserves the right to make revisions and changes in the operation manual at any time and without notice, and also to make changes in the device without influencing its operation. This manual is an integral part of the device and it must be delivered to the user together with the device. In order to ensure correct operation of the equipment, get thoroughly acquainted with this manual and keep it for the future. Vi ringraziamo per aver acquistato l’Aerotermo PRO-AIR....

 Open the catalog to page 2
PRO-Air EPP-3

‘Acoustic pressure level has been measured 5m from the unit in a 1500m3 space with a medium sound absorption coefficient * Il livello di pressione acustica e stato misurato a 5m di distanza dall'unita in uno spazio di 1500m3con un coefficiente medio del suono di assorbimento .

 Open the catalog to page 3
PRO-Air EPP-4

4. Tabella prestazioni riscaldamento Tp1 V - airflow - portata d'aria PT - heat capacity - capacita termica Tp1 - inlet air temp.- temperatura ingresso aria Tp2 - outlet air temp.- temperatura uscita aria Tw1 - inlet water temp. .- temperatura ingresso acqua Tw2 - outlet water temp.- temperatura uscita acqua. Qw - water flow rate - portata acqua Apw- pressure drop of water - caduta pressione acqua

 Open the catalog to page 4
PRO-Air EPP-5

1. Fan heaters can be mounted to vertical or horizontal partitions in any position. During the montage, the minimal distances from the walls and ceiling have to be kept. While mounting the unit under the ceiling via pins is needed to use flexible water pipes. 2. U-sections to suspend the device under the ceiling. Removing the brackets and mounting them in other places of the eater is not allowed. 1. Gli Aerotermi possono essere montati orizzontalmente o verticalmente. Durante il montaggio devono essere mantenute le distanze minime dalle pareti e dal soffitto. Durante il montaggio dell’ apparecchio...

 Open the catalog to page 5
PRO-Air EPP-6

The Pro-Air bracket makes it possible to: • Mount the device on the wall in vertical position or inclined at 45o or 60 o, • Mount the device under the ceiling in horizontal position or inclined at 45o or 60 o. • It is possible to rotate it along the points of the bracket connection with the unit. Expansion bolts are not included in the set. Type of the Bolts should be chosen appropriately to the type of the wall. La staffa Pro-Air consente di: • Montare il dispositivo sulla parete in posizione verticale o inclinato a 45 ° o 60 • Montare il dispositivo sotto il soffitto in posizione orizzontale...

 Open the catalog to page 6
PRO-Air EPP-7

PRO-AIR - method for controlling the fan operation: PRO-AIR - metodo di controllo del funzionamento del ventilatore: M system – based on regulation of the heater efficiency according to the temperature. The heater operation is regulated by controllers (VNT20) that automatically adjust its heat capacity to changing conditions inside the room. The controller smoothly adjusts fan’s airflow in range of 0 – 100% depending on the temperature difference: set on the controller and measured. M system – si base sulla regolazione dell’efficienza del riscaldatore in base alla temperatura. L’operazione del...

 Open the catalog to page 7
PRO-Air EPP-10

Guidelines for System Connection ■ The connection should be executed in a way which does not induce stresses. ■ It is recommended to install vent valves at the highest point of the system. ■ The system should be executed so that, in the case of a failure, it is possible to disassemble the device. For this purpose it is best to use shut-off valves just by the device. ■ The system with the heating medium must be protected against an increase of the heating medium pressure above the permissible value (1.6 MPa). ■ While screwing exchanger to pipeline - connecting stubs has to be hold by wrench. ■...

 Open the catalog to page 10
PRO-Air EPP-11

8. SERVICE AND WARRANTY TERMS Please contact your dealer in order to get acquitted with the warranty terms and its limitation. In the case of any irregularities in the device operation, please contact the manufacturer’s service department. The manufacturer bears no responsibility for operating the device in a manner inconsistent with its purpose, by persons not authorised for this, and for damage resulting from this! 8. ASSISTENZA E GARANZIA Si prega di contattare il vostro rivenditore per le condizioni ed i termini di garanzia. In caso di irregolarità nel funzionamento dell’apparecchio, si prega...

 Open the catalog to page 11
PRO-Air EPP-12

ITALKERO S.r.l. Via lumumba, 2 – Zona industrial Torrazzi – 41122 Modena – Italia Tel. +39 59 2550711 – Fax +39 59 4900500 http : //www.italkero.it E-mail : [email protected] Italkero PRO-Ai

 Open the catalog to page 12

Archived catalogs

  1. accessories

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.