AERE - 2

THE SILENCE BESTOWED BY NATURE IS COMPLETELY DIFFERENT TO THE ABSENCE OF NOISE. IT IS ALMOST DREAMLIKE: THE LIGHT, DISTANT BREATHING OF EARTH ELEMENTS WHICH COMMUNICATE PEACE AND SERENITY. THE SOUND INSULATION ISOSYSTEM PRODUCTS FORMING PART OF THE AERE COLLECTION AIM TO BESTOW THIS PRIMARY STATE WITHIN BUILDINGS, CLEANSING THE AIR OF BAD NOISES AND RESTORING NATURAL SOUND.

Open the catalog to page 2
AERE - 3

RANGING FROM FLOORING TO CEILINGS, WALLS TO FALSE CEILINGS, THE SOUND INSULATION PRODUCTS WITHIN THE AERE COLLECTION ARE CAPABLE OF PROVIDING SOLUTIONS FOR THE MOST DIFFICULT OF ISSUES RELATED TO NOISE, VIBRATIONS, WAVE PROPAGATION. HIGHLY SPECIALISED SYSTEMS,DEDICATED TO VARIOUS FUNCTIONS AND APPLICATIONS, ALL CAREFULLY TESTED AND CREATED IN A LARGE VARIETY OF MATERIALS.

Open the catalog to page 3
AERE - 4

AERE INSULATION SOUND Systems and products created in respect of the "Passive Acoustic Requirements for Buildings" according to Council of Ministers Presidential Decree 05/12/1997. Products are born from ISOSYSTEM experience, tested at the specialist acoustic laboratories and checked at the building yard on various types of buildings in order to determine the quality and ductility of the proposed system. • Council of Ministers Presidential Decree of the 05/12/1997 • UNI 11367, the new standard on acoustic classification • Sound-insulating and sound-absorbing wall panels. • Sound-insulating...

Open the catalog to page 4
AERE - 5

Table containing the Passive Requirements for buildings, their components and Technological Operation Systems. R'w: soundproofing power of partitioning elements D2mntw: standardized sound insulation of facade elements L'nw: normalized footfall noise level LASmax: maximum noise level of discontinuous operation systems LAeq: maximum noise level of continuous operation systems A: residential buildings B: office buildings C: hotel and accommodation buildings D: hospital and nursing homes buildings E: school and university buildings F: recreational and religious buildings G: buildings for...

Open the catalog to page 5
AERE - 6

ACUSTIC PET® page 23 ACUSTIC STAR® page 25 ACUSTIC SOFT® page 31 ACUSTIC LEAD® page 37 GESS FON STAR® page 41 GESS FON RUBBER® page 43 GESS FON IPB® page 47 GESS FON GUM® page 53 ACUSTIC SYSTEM® 7 page 55 ACUSTIC SYSTEM® 10 page 72 FONOROLL PLUS®/EXTRA PLUS® page 101 FONOROLL F® ADHESIVE/PB® ADHESIVE page 123 ISOVENT TERMO ACUSTIC® page 132 ACUSTIC BAND/ACUSTIC BAND N page 142 ACUSTIC BAND L/ACUSTIC BAND 90 page 143 ACUSTIC BAND 270/ACUSTIC BAND C page 144 ACUSTIC BAND G/ACUSTIC BAND D page 145 SONIK/SONIK ADHESIVE TAPE...

Open the catalog to page 6
AERE - 7

SOUND-INSULATING AND SOUND-ABSORBING WALL PANELS

Open the catalog to page 7
AERE - 8

SOUND-INSULATING AND SOUND-ABSORBING WALL PANELS

Open the catalog to page 8
AERE - 9

Mineral wool Plastomeric material Mineral wool TECHNICAL CHARACTERISTICS “ACUSTIC RC®”, is a sound insulating and sound absorbing panel, self bearing and rabbeted on two sides, made up of two layers (20 mm thick) of high density mineral wool, with plastomeric material 7.5 Kg/m2 nominal in between. Panel thickness 47 mm nominal Panel dimensions: 1000x600 mm. STANDARD FORMATS 1000X600 mm rabbeted on 2 long sides Panel thickness 47 mm nominal m2 30 per pallet TECHNICAL INFORMATION Self bearing panel Panel weight: 13/14 kg/m2 nominal Thermal conductivity λD: 0.037 W/m°K Thermal resistance 40 mm...

Open the catalog to page 9
AERE - 10

Faculty of Engineering, Padova University. Determination of a building section sound insulating power carried out in a laboratory environment in accordance with EN ISO 140-3 standards Test sample description: J 1 plaster 1.5 cm. J 2 perforated brick 8 cm. J 3 ACUSTIC RC® J 4 hollow brick 12 cm. 5 plaster 1.5 cm. Wall thickness approx. 27 cm. Test result: Assessment index according to UNI EN ISO 717-1 standards Rw=54dB Test sample description: 1 plaster 1.5 cm. 2 perforated brick 8 cm. J 3 ACUSTIC RC® J 4 hollow brick 12 cm. 5 plaster 1.5 cm. j 6 Isorubber band 0.5 cm. Wall thickness approx....

Open the catalog to page 10
AERE - 11

Test sample description: 1 plaster 1.5 cm. J 2 perforated brick 12 cm. J 3 ACUSTIC RC® J 4 perforated brick 12 cm. J 5 plaster 1.5 cm. j 6 Isorubber band 0.5 cm. Wall thickness approx. 32 cm. Test result: Assessment index according to UNI EN ISO 140-4:2000 standards R'w=53dB Test sample description: J 1 plaster 1.5 cm. J 2 perforated brick 12 cm. 3 ACUSTIC RC® 4 perforated brick 12 cm. 5 plaster 1.5 cm. 6 Isorubber band 0.5 cm. Wall thickness approx. 32 cm. Test result: Assessment index according to UNI EN ISO 140-4:2000 standards R'w=58dB

Open the catalog to page 11
AERE - 12

ACUSTIC RC®RESULTS OF TESTS CARRIED OUT AT THE BUILDING YARD, DATED 16-10-2007 (see certificate 1F) Building yard: Via C. Percotto, Castions di Strada (UD) Test sample description: J 1 plaster 1.5 cm. J 2 hollow brick 12 cm. J 3 rendering 1 cm. j 4 ACUSTIC RC® j 5 hollow brick 12 cm. J 6 plaster 1.5 cm. J 7 Isorubber band 0.5 cm. Wall thickness approx. 27 cm. Test result: Assessment index according to UNI EN ISO 140-4:2000 standards R'w=62dB CONTRACT SPECIFICATIONS Wall sound insulation will be achieved as follows: Installation of “ACUSTIC RC®”, a sound insulating and sound absorbing panel...

Open the catalog to page 12
AERE - 13

LABORATORY TEST NO 0002-B/DC/ACU/08 DATED 29-01-2008 (1A)

Open the catalog to page 13
AERE - 14

ACUSTIC RCLABORATORY TEST NO 0002-B/DC/ACU/08 DATED 29-01-2008 (1A) 5 - T, 30di ■ V - flfcfP iscmJ fl. RRSP* Mivisidiu-CoStrnjimii Division Mend ItRESP. DEL CENTRO Marine inn Director P, Cau M*U

Open the catalog to page 14
AERE - 16

facoctA DI INGEGNERJA dell UNI VERS iTA D| P^COV/A Ddserizioite tioJl'etemtuito in fifoVa*. pamte con interrapedine, intonacata ambo i lali (spessore intonaco 1,5 cm), realizzata con btocchi semipiejii di laterizio poriz2ato (50x253112 cm} e Iramozza normali (50x25x5 cm} con intftrpnsti pannelli ISOSYSTEM "ACUSTIC RC* (100x50x3,5 cm) posali a secco. II panne No ISOSYSTEM "ACUSTIC RC" 6 composlo da uno strato di lana di media (spflssone 15 mm), un compound bituminoso elastoplastomerico (spessore -5 mm) e da uno slrato di 'ana di roeda (spessore 15 mm). Cpitdizioni di piwar_ Superficie...

Open the catalog to page 16

All ISOSYSTEM catalogs and technical brochures

  1. DEKORSYSTEM

    24 Pages

  2. TERRAE

    60 Pages

  3. GESS FON PSE

    1 Pages

  4. GESS FON EST

    1 Pages

  5. eps 120 kpa

    1 Pages

  6. gess fon LV

    1 Pages

  7. acustic rc

    12 Pages

Archived catalogs

  1. ISORUBBER

    8 Pages

  2. FONOSYSTEM

    6 Pages

  3. FONOROLL PB

    2 Pages

  4. FONOROLL F

    10 Pages

  5. GESS FON RC

    2 Pages

  6. GESS FON PB

    1 Pages