1. Catalogs
  2. inVENTer
  3. Better ventilation with heat recovery

Better ventilation with heat recovery

Better ventilation with heat recovery

Better ventilation with heat recovery

Product catalog summary
Overview: The document discusses the benefits and technical specifications of inVENTer ventilation systems, particularly focusing on their application in office environments to improve air quality and control aerosols.
Aerosol Control: In offices with multiple occupants, aerosols can spread quickly, increasing infection risks. Regular air exchange is crucial but can lead to cooling. Decentralized ventilation provides basic ventilation while maintaining a comfortable climate.
Installation and Features: The inVENTer systems are easy to retrofit, requiring a core drill for installation. They feature intuitive control for ventilation intensity and include heat recovery to maintain comfortable indoor temperatures.
Heat Recovery: The system uses a ceramic core to store and release heat, ensuring fresh air is not too cool, thus maintaining a comfortable indoor climate.
iV-Office System: This system offers high performance with minimal noise, utilizing the Xenion® EFP fan and Inventin® sound insulation. It supports up to four systems controlled by the sMove controller, which offers intuitive touch and slide controls.
Technical Specifications:
  • Exhaust Air Volume Flow: 20 – 90 m³/h
  • Air Volume Flow HR: 10 – 45 m³/h
  • Heat Recovery Efficiency: 88%
  • Power Consumption: 1 – 5 W
  • Sound Emission: 14 – 41 dB(A)
  • Energy Efficiency Class: A+ / A
Optional sensors like the CO2 sensor CS1 are available.
Office Ventilation Requirements: To prevent high CO2 levels and infection risks, the workplace directive recommends CO2 concentrations not exceed 1,000 ppm. Mechanical ventilation with heat recovery is advised to minimize cooling from window ventilation.
Planning Recommendations:
  • For 2-person offices: 2 x iV-Office systems, providing 30 m³/h per device and person.
  • For 4-person offices: 2 x iV-Office systems, providing 15 m³/h per person, with temporary increases to 90 m³/h possible.
These setups ensure compliance with noise emission requirements and reduce virus concentration through fresh air exchange.
Contact Information: For planning proposals or specific project inquiries, contact inVENTer GmbH via email at [email protected] or visit their website at www.inventer.eu.
See more

Catalog excerpts

Better ventilation with heat recovery-1

Better ventilation with heat recovery The ventilation support for public spaces

 Open the catalog to page 1
Better ventilation with heat recovery-2

Healthy indoor air with a comfortable temperature Aerosol control In an office where several people are present, aerosols contaminated with viruses can spread quickly and increase the risk of infection. A regular exchange of air is essential, but it also cools down the interior quickly. The decentralized ventilation enables basic ventilation and ensures a comfortable climate in the office. Quick installation Easy to retrofit: inVENTer ventilation systems are inserted in pairs into the outer wall using a core drill. The ventilation intensity can be set intuitively when connected to the controller....

 Open the catalog to page 2
Better ventilation with heat recovery-3

In the office, where there is concentrated work and lively Office rooms must be designed in such a way that: “There discussions, the CO2 concentration rises quickly. This can is sufficient health-beneficial breathing air available” (ASR lead to concentration problems and headaches, but also A3.6, p. 3). In order to minimize the necessary boost increases the risk of infection with infectious diseases. ventilation cycles and thus prevent the office space from According to the workplace directive, the concentration cooling down, we recommend ventilation support by of CO2 should not exceed 1,000...

 Open the catalog to page 3
Better ventilation with heat recovery-4

inVENTer GmbH Ortsstraße 4a D-07751 Löberschütz Phone: +49 (0) 36427 211-0 Fax: +49 (0) 36427 211-113 E-mail: [email protected] Web: www.inventer.eu Version: 07/2021 No liability accepted for printing errors.

 Open the catalog to page 4

All InVENTer catalogs and technical brochures

  1. iV-Twin+

    1  Page

  2. sMove

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.