Catalog excerpts
Product Overview
Open the catalog to page 1Ingeteam Proprietary – All Rights Reserved
Open the catalog to page 2Table of Contents 1 Introduction Ingeteam Proprietary – All Rights Reserved
Open the catalog to page 36 INGESYS™ IC2 Selection Table Ingeteam Proprietary – All Rights Reserved
Open the catalog to page 4Ingeteam Proprietary – All Rights Reserved
Open the catalog to page 5Introduction INGESYS™ IC2 is a standalone Controller with an internal modular and expandable design, oriented to fulfill the requirements of control applications demanding a reduced number of digital/analog I/Os, IEC61131 standard based programmable languages, wide range of communication interfaces and remote monitoring features based on an embedded Web server. INGESYS™ IC2 offers two variants each one with specific characteristics for the target application sector: - Variant for the Rolling stock control in the railway sector. This variant identified by the code R in the product reference...
Open the catalog to page 6Hardware Description Ingeteam Proprietary – All Rights Reserved
Open the catalog to page 7Hardware Description Hardware Description INGESYS™ IC2 has a modular and expandable design that permits to achieve an optimal hardware solution for each application. Two control topologies are available: - Centralized topology In this topology the Controller is integrated by a single central system that incoporates a processor module and up to 10 I/O modules in a compact mechanical enclosure - Distributed topology In this topology the Controller is integrated by the central system expanded with up to 16 Remote I/Os units connected by a CAN fieldbus. Remote I/O units are integrated by a...
Open the catalog to page 8Hardware Description Inge team 2.1 Power Supply Two possible power supply modules are available for 24Vdc or 72-110Vdc voltages, each one for two specific sector: Industrial or Rolling Stock - Railway . Main characteristics of these power supply modules are: 2.1.1 24Vdc Tbl 1. Power Supply. 24Vdc Technical Data. Power Supply Tbl 2. Power Supply. 72-110Vdc Technical Data. Connector pinout is as follows: 1. Power supply connector. Fig Note: (A1-B1), (A2- B2), (A3- B3) internally tied. Ingeteam Proprietary - All Rights Reserved Pag. 9
Open the catalog to page 9Hardware Description Inge team 2.2 Processor Module INGESYS™ IC2 offers different processor module types, IC2-C, IC2-HC,IC2-HCS, IC2-PC and IC2-PCS that share some common characteristics but at the same time offer specific properties in aspects like: data and program memory, communications, programming tools, logging and Webserver capabilities. Common and specific characteristics of these processor modules are described in following table: Ingeteam Proprietary - All Rights Reserved Pag. 10
Open the catalog to page 10Hardware Description Inge team Tbl 5. Specific processor characteristics. Ingeteam Proprietary - All Rights Reserved Pag. 11
Open the catalog to page 11Hardware Description Inge team Tbl 6. Processor module status LEDs. Ingeteam Proprietary - All Rights Reserved Pag. 12
Open the catalog to page 12Hardware Description Inge team 2.3 Header Module Header modules enable the integration of inputs / outputs modules in a distributed Remote I/O unit. Remote I/O units are accessed by the main processor through an expansion bus. This bus can be: • CAN • RTSX 2.3.1 Header module CAN CAN Remote I/O units are accessed by the main processor through the CAN expansion bus, in each CAN bus is possible to connect up to 16 Remote I/O units. Parameter configuration and EDS file generation is made by the internal Web server included in the header module. Main characteristics of these header modules are:...
Open the catalog to page 13Hardware Description Inge team 2.3.2 Header module RTSX RTSX Remote I/O units are accessed by the main processor through the RTSX expansion bus. In this bus is possible to connect up to 16 Remote I/O units. Parameter configuration is made in the main program, similar to parameter configuration of local I/Os, adding a configuration file provided for each header module reference. Main characteristics of these header modules are: Tbl 11. INGESYS™ IC2 interface modules. Ingeteam Proprietary - All Rights Reserved Pag. 14
Open the catalog to page 14Hardware Description Inge team 2.4.1 Fieldbuses interfaces In the case of fieldbus based communications, the INGESYS™ IC2 enables the user the selection of different hardware interface modules, currently available are CAN (Master/Slave), MVB, PROFIBUS DP, RS232/485, PROFINET I/O-Device RT. In the case of C type processors up to two fieldbus interfaces can be integrated, for HC/HCS type processors up to four fieldbus interfaces can be integrated. Main characteristics of these fieldbus interfaces are described in following sections: 2.4.1.1 CAN interface module There are two available CAN...
Open the catalog to page 15Hardware Description Inge team Tbl 15. CAN fiber optic interface connector pinout. Ingeteam Proprietary - All Rights Reserved Pag. 16
Open the catalog to page 16Hardware Description Inge team 2.4.1.2 MVB interface module There are four available MVB interface modules depending on the desired electrical distance. 2.4.1.2.1 MVB ESD+ interface module In the case of MVB communication bus, the INGESYS™ IC2 behaves as a MVB Class 1 device with up to 16 ports configurable as input or output. Main characteristics: Tbl 16. MVB ESD+ interface module characteristics. Connectors pinout is as follows: Ingeteam Proprietary - All Rights Reserved Pag. 17
Open the catalog to page 17Hardware Description Inge team 2.4.1.2.2 MVB EMD interface module In the case of MVB communication bus, the INGESYS™ IC2 behaves as a MVB Class 1 device with up to 16 ports configurable as input or output. Main characteristics: Tbl 17. MVB EMD interface module characteristics. Connectors pinout is as follows: Ingeteam Proprietary - All Rights Reserved Pag. 18
Open the catalog to page 18Hardware Description Inge team 2.4.1.2.3 MVB EMD-R module In the case of MVB communication bus, the INGESYS™ IC2 behaves as a MVB Class 1 device with up to 128 ports configurable as input or output. Main characteristics: Tbl 18. MVB EMD-R interface module characteristics. Connectors pinout is as follows: Ingeteam Proprietary - All Rights Reserved Pag. 19
Open the catalog to page 19Hardware Description Inge team 2.4.1.2.4 MVB EMD SNFR module Enables the INGESYS™ IC2 to behave as a MVB Sniffer capable of reading up to 4096 ports on the MVB bus. Main characteristics: Tbl 19. MVB EMD SNFR interface module characteristics. Connectors pinout is as follows: Ingeteam Proprietary - All Rights Reserved Pag. 20
Open the catalog to page 20All Ingeteam catalogs and technical brochures
-
INGECON SUN FSK
4 Pages
-
INGECON SUN StringStation
4 Pages
-
INGECON SUN Power TL
4 Pages
-
INGECON SUN Power
4 Pages
-
INGECON SUN Monitor
2 Pages
-
INGECON SUN Manager
2 Pages
-
INGECON SUN Lite TL
2 Pages
-
INGECON SUN 3Play TL M
4 Pages
-
INGECON SUN 3Play TL
4 Pages
-
INGECON SUN 3Play 100 TL
4 Pages
-
INGECON SUN 1Play TL M
4 Pages
-
INGEREV CITY Duo
2 Pages
-
INGEREV CITY
2 Pages
-
INGECON SUN
2 Pages