VICTRIX PRO 2 ErP - 1

HIGH POWER VICTRIX PRO 2 ErP High power, wall-hung condensation boiler

Open the catalog to page 1
VICTRIX PRO 2 ErP - 4

VICTRIX PRO 2 ErP is the new range of wall-hung condensing boilers for room heating only, set-up for independent functioning and for set configuration (up to 5 appliances), with the advantage of guaranteeing higher overall output and reduced running costs. All models can be installed indoors or outdoors (in the open), on walls or on a new load-bearing frame, offering flexible solutions to professionals who need to size heating control units based on the buildings. Condensation technology allows to obtain particularly high performance (η>93+2•log Pn) in compliance with Legislative Decree...

Open the catalog to page 4
VICTRIX PRO 2 ErP - 5

Wall-hung, open-chamber and fan-assisted pre-mixed condensing boilers, high efficiency with forced circulation, with a maximum heat output for 50/30 °C of: VICTRIX PRO 35 2 ErP = 37.3 kW (32.155 kcal/h) VICTRIX PRO 55 2 ErP = 54.8 kW (47.097 kcal/h) Type-approved for installation in heating control unit and outside the building without any additional protection (in the open), it can be used in two configurations: Open chamber and fan assisted (appliance type B23p/ B33/ B53p) No additional kit is required for this factory-supplied configuration. Sealed chamber and fan assisted (appliance...

Open the catalog to page 5
VICTRIX PRO 2 ErP - 6

Wall-hung, open-chamber and fan-assisted pre-mixed condensing boilers, high efficiency with forced circulation, with a maximum heat output for 50/30 °C of: VICTRIX PRO 80 2 ErP = 80.3 kW (68.994 kcal/h), VICTRIX PRO 100 2 ErP = 98.8 kW (84.942 kcal/h), VICTRIX PRO 120 2 ErP = 121.7 kW (104.682 kcal/h); Type-approved for installation in heating control unit and outside the building without any additional protection (in the open), it can be used in two configurations: Open chamber and fan assisted (appliance type B23p/ B33/ B53p) - No additional kit is required for this factory-supplied...

Open the catalog to page 6
VICTRIX PRO 2 ErP - 7

VICTRIX PRO 35 - 55 ErP MAIN PARTS KEY: 1 - P.C.B. 2 - Gas valve 3 - System pressure switch 4 - Gas nozzle 5 - Sleeve with seats for Venturi 6 - Air fan 7 - System flow regulation NTC probe 8 - Overheating safety thermostat 9 - Detection electrode 10 - Manifold cover 11 - Condensation module cover 12 - Igniter 13 - Ignition electrode 14 - Flue probe 15 - Condensing module air vent valve 16 - Fumes hood 17 - Sample points (air A) - (flue gas F) 18 - Heat exchanger safety thermal fuse 19 - Manual air vent valve 20 - Condensation module 21 - Heat-exchanger safety thermostat (manual reset) 22 -...

Open the catalog to page 7
VICTRIX PRO 2 ErP - 8

VICTRIX PRO 80 - 100 - 120 2 ErP MAIN PARTS KEY: 1 - Draining funnel. 2 - Gas cock 3 - Pump 4 - Gas nozzle 5 - Overheating safety thermostat 6 - Burner 7 - System return regulation NTC probe 8 - System flow regulation NTC probe 9 - Condensing module air vent valve 10 - Flue probe 11 - Condensation module 12 - Fumes hood 13 - Air intake pipe 14 - Igniter 15 - Heat-exchanger safety thermostat (manual reset) 16 - Heat exchanger safety thermal fuse 17 - Ignition electrode 18 - Detection electrode 19 - Condensation module cover 20 - Manifold cover 21 - Sleeve with seats for Venturi 22 -...

Open the catalog to page 8
VICTRIX PRO 2 ErP - 9

VICTRIX PRO 35 - 55 2 ErP MAIN DIMENSIONS Model Cover upper line SC = Condensate drain 25 Ø mm Distance between cover upper line and 80 Ø drain bend axis: 160 mm Model VICTRIX PRO 35 2 ErP VICTRIX PRO 55 2 ErP Distance between cover upper line and concentric intake-exhaust bend axis Ø 80/125 190 mm

Open the catalog to page 9
VICTRIX PRO 2 ErP - 10

VICTRIX PRO 80 2 ErP MAIN DIMENSIONS Model Cover upper line SC = Condensate drain 25 Ø mm Distance between cover upper line and 80 Ø drain bend axis: 160 mm Distance between cover upper line and concentric intake-exhaust bend axis Ø 80/125 190 mm

Open the catalog to page 10
VICTRIX PRO 2 ErP - 11

VICTRIX PRO 100 - 120 2 ErP MAIN DIMENSIONS Model Cover upper line SC = Condensate drain 25 Ø mm Distance between cover upper line and 80 Ø drain bend axis: 160 mm Model VICTRIX PRO 100 2 ErP VICTRIX PRO 120 2 ErP Distance between cover upper line and concentric intake-exhaust bend axis Ø 80/125 190 mm

Open the catalog to page 11
VICTRIX PRO 2 ErP - 12

HYDRAULIC KIT MEASUREMENTS AND FITTINGS (OPTIONAL) VICTRIX PRO 35 - 55 2 ErP WITH INDIVIDUAL BOILER N.B.: In case of installation outside, the safety devices kit must be protected using the IPX4D protection box kit for individual boiler safety devices, code 3.024028. Immergas S.p.a. declines all liability whenever the installer does not use approved devices and Immergas original kits or uses them improperly. The sensitive elements of the safety devices must be set up as described in the installation instructions, in compliance with the provisions cascade forth in the "R" collection. For...

Open the catalog to page 12
VICTRIX PRO 2 ErP - 13

HYDRAULIC KIT MEASUREMENTS AND FITTINGS (OPTIONAL) VICTRIX PRO 80 - 100 - 120 2 ErP WITH INDIVIDUAL BOILER N.B.: In case of installation outside, the safety devices kit must be protected using the IPX4D protection box kit for individual boiler safety devices, code 3.024028. Immergas S.p.a. declines all liability whenever the installer does not use approved devices and Immergas original kits or uses them improperly. The sensitive elements of the safety devices must be set up as described in the installation instructions, in compliance with the provisions cascade forth in the ''R''...

Open the catalog to page 13
VICTRIX PRO 2 ErP - 14

INAIL SAFETY DEVICE KIT FOR SINGLE BOILER (CODE 3.023949) FOR VICTRIX PRO 35 - 55 - 80 - 100 - 120 2 ErP The safety device kit is type-approved for vertical installation directly under the boiler, placing the relative gaskets in between. With outdoor installation it needs to be protected using the IPX4D protection box kit for single boiler safety devices, code 3.024028, or nonetheless protected from the elements based on its electrical protection rating. Immergas declines all liability whenever the installer does not use original Immergas devices and kits, or uses them improperly. The...

Open the catalog to page 14
VICTRIX PRO 2 ErP - 15

VICTRIX PRO 2 ErP 11 THREE-WAY VALVE KIT FOR COMBINATION WITH SEPARATE STORAGE TANK UNIT (CODE 3.023950) FOR VICTRIX PRO 35 - 55 - 80 - 100 - 120 2 ErP The kit is sized for single boiler operation or in combination with a separate boiler for D.W.H. production. The output of the boiler in domestic hot water operation must be set based on the heat exchange output of the coil supplied with the storage tank. The diverter valve (which is powered by 230 Vac) comes installed on the flow pipe in combination with a blind manifold (3), reducing the overall installation footprint. The standard kit...

Open the catalog to page 15

All Immergas catalogs and technical brochures

  1. SUPER TRIO

    24 Pages

  2. FANCOIL UNITS

    20 Pages

  3. AUDAX

    114 Pages

  4. MAGIS COMBO V2

    36 Pages

  5. CATALOGUE

    216 Pages

  6. LUXOR

    16 Pages

  7. VICTRIX TERA

    12 Pages

  8. WATER HEATERS

    16 Pages

  9. CATALOGUE_2018

    200 Pages

  10. HEAT PUMPS

    60 Pages

  11. CATALOGUE 2018

    176 Pages

  12. RAPAX V2

    8 Pages

  13. MAGIS COMBO

    20 Pages

  14. Catalogue 2016

    71 Pages

Archived catalogs

  1. CATALOGUE_2016

    140 Pages

  2. HEAT PUMPS

    40 Pages