VICTRIX MAIOR TT RANGE Wall-hung combi and only-heating condensing boiler
Open the catalog to page 1ENERGY LABEL AND ErP REGULATIONS WE ARE READY TO DO OUR BIT FOR THE ENVIRONMENT We are talking about a very important European Union directive, an effective strategy that will drive to in reduced pollution and therefore improve the life of citizens all over Europe. The ErP directive (2009/125/CE) - the acronym stands for “Energy Related Products” - assesses very precise guidelines for design and the manufacturing of eco-compatible products and defines the minimum mandatory requirements for the efficiency and environmental performance of all power-consuming devices. The goal is to reach the...
Open the catalog to page 2VICTRIX MAIOR TT RANGE Comfort, savings, Top Tech technology This is the most advanced range in the “Top Tech” platform, produced in the high-automation lines of the original headquarters of Immergas, in Brescello. CONDENSATION TECHNOLOGY FOR HIGHER ENERGY CLASS Two instantaneous versions (28 and 35 kW) and a heating-only version (35 kW): together they create a perfect range to meet the new European Directives on energy use, which is increasingly focused on condensation technology. All the models feature a low consumption modulating circulator, designed to achieve high efficiency...
Open the catalog to page 3Modulation range from 10% to 100% HIGH HYDRAULIC PERFORMANCE The design of the new condensing module features wide water passages to enable excellent flow rate and head performance even on old heating systems. This also means reduced clogging risk when impurities are present in the water of the system. The special aluminium-silica-magnesium alloy used for construction, together with the accessories used, makes the unit particularly resistant to corrosion. The ascending pathway of the water circuit in the exchanger flows countercurrent to the flame. The closely fitted elements increase the...
Open the catalog to page 4TECHNICAL DATA Technical data ^1 VICTRIX MAIOR TT/35 X TTWall-hung combi and only-heating condensing boiler MAIN CHARACTERISTICS ^1 Available 28 and 35 kW combi version and 35 kW heating-only version ^1 Ecofriendly - low NOx emissions (class 5) ^1 Design with panel cover flap ^1 New condensing module with high circulation ^1 Modulating heat output from 10 to 100% ^1 Gas adaptive through control board parameters; only one product code (natural gas) ^1 Low consumption modulating pump ^1 NTC probes for system delivery and return as standard ^1 Adjustable system by-pass Possible installation...
Open the catalog to page 5TECHNICAL DATA TECHNICAL DATA PRODUCT INFORMATION (IN ACCORDANCE WITH REGULATION 811/2013) In accordance with the ELD directive, we include the label of each boiler to enable customers to evaluate the products. The labels are shown in the documentation accompanying the units as well as on the immergas.com website in each product’s page. 24 VICTRIX 28/35 TT hydraulic connections ENERGg® ©0 VICTRIX 35 X TT hydraulic connections * Only in case of storage tank connection kit
Open the catalog to page 6CLIMATIC REGULATION CLIMATIC REGULATION CLIMATIC REGULATION Combining the VICTRIX MAIOR TT range with a heat regulation device is an excellent investment because it improves the seasonal energy efficiency of the heating system. For each of the following heat regulation devices we therefore indicate a class, which gives you the percentage value of increased efficiency. CARV2 (Modulating remote control) Type Modulating thermostat with remote boiler controls; includes special functions such as antifreeze temperature settings and anti-legionnaire function (only for boilers with DHW storage...
Open the catalog to page 7OPTIONAL Inside the various range of options it is possible to find out complementary accessories for installing VICTRIX MAIOR TT. The use of original kits enhances quality and reliability of the products. Magnetic cyclone filter kit (code 3.024176) For combi boiler only. Approved for installation inside the building Important in case of boiler replacement in order to restrain possible ferrous. It connects the so called “cyclonic effect” (impurities removal through a circular motion of water) to the magnetic one. This is possible thanks to a rod containing permanent magnets located in...
Open the catalog to page 8Immergas S.p.A. 42041 Brescello (RE) - Italy T. 0522.689011 F. 0522.689178 Oimmergas ■ I ■■ : m IMMERGAS SPA - ITALY CERTIFIED COMPANY UNI EN ISO 9001:2008 Design, manufacture and post-sale assistance of gas boilers, gas water heaters and related accessories Immergas reserves the right to make such changes to its products as are deemed necessary for their evolution, without prior notice. Cod. CE. 0447 - rev. 001 (ver. 591) - 09/15 - grafiche PIOPPI - Scandiano (RE)
Open the catalog to page 9All Immergas catalogs and technical brochures
-
SUPER TRIO
24 Pages
-
FANCOIL UNITS
20 Pages
-
VICTRIX PRO 2 ErP
94 Pages
-
AUDAX
114 Pages
-
MAGIS COMBO V2
36 Pages
-
CATALOGUE
216 Pages
-
LUXOR
16 Pages
-
VICTRIX ZEUS 25
12 Pages
-
VICTRIX TERA
12 Pages
-
WATER HEATERS
16 Pages
-
CATALOGUE_2018
200 Pages
-
VICTRIX EXA ErP range
16 Pages
-
HEAT PUMPS
60 Pages
-
CATALOGUE 2018
176 Pages
-
VICTRIX PRO RANGE
28 Pages
-
RAPAX V2
8 Pages
-
MAGIS COMBO
20 Pages
-
Catalogue 2016
71 Pages
-
Heat Pumps_2016
21 Pages
Archived catalogs
-
THERMAL SOLAR SYSTEMS
84 Pages
-
CATALOGUE_2016
140 Pages
-
HEAT PUMPS
40 Pages
-
Thermal solar systems
45 Pages