Catalog excerpts
HEAT PUMPS Hybrid heat pump
Open the catalog to page 1MAGIS COMBO Heat pump and condensing: the intelligence and efficiency of hybrids MAGIS COMBO is the hybrid heat pump that heats, cools and produces hot water with an internal condensing unit designed to meet the highest demands. The outdoor condensing unit is available in 3 single-phase versions: 5, 8 and 10 kW. The internal unit is equipped with a condensing generator (27 kW for hot water production and 24 kW for heating) and an integrated hydronic module that controls the exchange of energy between the refrigeration circuit and the water circuit. MAGIS COMBO takes up little space and,...
Open the catalog to page 2SOLUTIONS FOR NEW HOMES MAGIS COMBO extends the Immergas range of split solutions, which started with MAGIS PRO ErP. These systems require installation by qualified professionals with F-GAS license for refrigeration connection between the two units. Ideal for achieving very high energy ratings in new residential buildings. INCENTIVE FOR REPLACEMENT Compared to a condensing boiler, it offers greater savings in management costs. INTEGRATED INTELLIGENT ELECTRONICS The circuit board assigns priority to internal unit or heat pump based on weather conditions, to ensure top performance in any...
Open the catalog to page 3TECHNICAL DATA MAIN FEATURES INTERNAL UNIT 48 plates R41OA / water exchanger Stainless steel condensing module 10 litres expansion vessel Flowswitch that activates heat pump unit just if the water flow rate is enough Hydraulic group - 7,5 head m.w.c. low consumption circulator for heat pump unit (in the PLUS version can manage also DHW mode) Hydraulic group - 7 head m.w.c. low consumption circulator for condensing internal unit circuit PCB prearranged to manage 2 zones (without System controller), 1 direct and 1 mixed temperature (heating and cooling) System Controller (optional) to...
Open the catalog to page 4TECHNICAL DATA MAIN FEATURES OUTDOOR CONDENSING UNIT (AUDAX PRO) Inverter technology rotative compressor for all models Preloaded refrigerant GAS R410A Shut off knobs R410A as standard Air finned heat exchanger (with single fan) Electronic lamination valve 4-way valve for cycle inversion Reversible heating and cooling function Possible installation outdoor without protection
Open the catalog to page 5SYSTEM EXAMPLE MAGIS COMBO DHW storage tank UB INOX SOLAR 200 ErP Storage tank NTC probe Flat-Plate solar collectors Solar collector probe Buffer tank (to dimension) Distribution manifold kit (2 zones) Temperature/humidity active sensor kit 7 3 Water supply network EXAMPLE OF CONFIGURATION FOR MAGIS COMBO WITH TWO SYSTEM ZONES Installation is also recommended as replacement of existing boilers in systems with fan coils or mediumtemperature radiators. Room heating mode MAGIS COMBO is switched on by a request from one of the two system zones. If the time required to reach full capacity is...
Open the catalog to page 6SYSTEM EXAMPLE MAGIS COMBO PLUS Photovoltaic inverter Photovoltaic panel Thermostatic mixing valve DHW storage tank INOXSTOR ErP Storage tank NTC probe Safety inlet kit (not included) Buffer tank (to dimension) Distribution manifold kit (2 zones) Temperature/humidity active sensor kit EXAMPLE OF CONFIGURATION FOR MAGIS COMBO PLUS WITH TWO SYSTEM ZONES AND PHV SYSTEM Ideal installation in new homes to achieve a high energy efficiency rating and large % of power from Renewable Energy Sources. Room heating mode MAGIS COMBO PLUS is switched on by a request from one of the two system zones. If...
Open the catalog to page 7Technical data reported may be subject to change. For more information consult the technical sheet or the website immergas.com
Open the catalog to page 8PRODUCT INFORMATION MAGIS COMBO 5 In accordance with the ELD directive (in conformity with regulation 811/2013), we include the label of each water heater to enable customers to evaluate the products. The labels are shown in the documentation accompanying the units as well as on the immergas.com website in each product’s page.
Open the catalog to page 9Technical data reported may be subject to change. For more information consult the technical sheet or the website immergas.com
Open the catalog to page 10PRODUCT INFORMAZION MAGIS COMBO 5 PLUS In accordance with the ELD directive (in conformity with regulation 811/2013), we include the label of each water heater to enable customers to evaluate the products. The labels are shown in the documentation accompanying the units as well as on the immergas.com website in each product’s page. MAGIS COMBO 5 PLUS MAGIS COMBO 8 PLUS MAGIS COMBO 10 PLUS MAGIS COMBO 10 PLUS MAGIS COMBO 8 PLUS
Open the catalog to page 11V Electrical connection G Gas supply LP Liquid refrigerant GP G as refrigerant AC Domestic hot water outlet AF Domestic cold water inlet SC Condensate drain (minimum internal diameter 13 mm) R Syst em return M Syst em flow Hydraulic connections MAGIS COMBO PLUS Key V Electrical connection G Gas supply LP Liquid refrigerant GP G as refrigerant RU Return storage tank MU Flow storage tank RR Syst em f lling SC Condensate drain (minimum internal diameter 13 mm) R Syst em return M Syst em flow To ensure correct installation of internal unit, the air inlet/flue outlet pipes kit must be selected...
Open the catalog to page 12Hydraulic connections Hydraulic connections
Open the catalog to page 13TECHNICAL DATA Technical note - System minimum water content: To facilitate proper execution of the heat pump defrost cycles, a minimum water content in the system is required, which must be: 7 l/kW of the machine's power for any type of system. So attention must be paid to the systems divided over several zones, where the water content available to the machine changes continuously. This is why it may be necessary to provide a heating flywheel that guarantees normal operation with systems divided into zones (with variable water content in circulation). This minimum content also guarantees...
Open the catalog to page 14TECHNICAL DATA Flow rate / head del circolatore unità interna Grafico portata/prevalenzagraph THERMAL UNIT CIRCUIT Flow rate / head graph HEAT PUMP CIRCUIT Pump consumption(W) Key Available head in the system Pump consumption The internal unit is supplied with two low power consumption pumps with variable speed control. The heat pump circulator speed is set via parameter “A04” (which can be set between 55% and 100%). The thermal unit circulator speed is set via parameter “A19” (which can be set between 45% and 100%). NOTE: for proper system operation, make sure that the minimum flow in...
Open the catalog to page 15All Immergas catalogs and technical brochures
-
SUPER TRIO
24 Pages
-
FANCOIL UNITS
20 Pages
-
VICTRIX PRO 2 ErP
94 Pages
-
AUDAX
114 Pages
-
MAGIS COMBO V2
36 Pages
-
CATALOGUE
216 Pages
-
LUXOR
16 Pages
-
VICTRIX ZEUS 25
12 Pages
-
VICTRIX TERA
12 Pages
-
WATER HEATERS
16 Pages
-
CATALOGUE_2018
200 Pages
-
VICTRIX EXA ErP range
16 Pages
-
VICTRIX MAIOR TT range
9 Pages
-
HEAT PUMPS
60 Pages
-
CATALOGUE 2018
176 Pages
-
VICTRIX PRO RANGE
28 Pages
-
RAPAX V2
8 Pages
-
Catalogue 2016
71 Pages
-
Heat Pumps_2016
21 Pages
Archived catalogs
-
THERMAL SOLAR SYSTEMS
84 Pages
-
CATALOGUE_2016
140 Pages
-
HEAT PUMPS
40 Pages
-
Thermal solar systems
45 Pages