Open the catalog to page 1Heat pump and condensing: the intelligence and efficiency of hybrids MAGIS COMBO V2 is the new hybrid heat pump that heats, cools and produces hot water with an internal condensing unit designed to meet the highest demands. The new outdoor condensing unit is available in 3 single-phase versions: 4, 6 and 9 kW with refrigerant R32 (the most ecological) that guarantees high efficiency in all operating conditions. The internal unit is equipped with a condensing generator (27,3 kW for hot water production and 24 kW for heating) and an integrated hydronic module that controls the exchange of...
Open the catalog to page 2MORE VALUE TO PROPERTY MAGIS COMBO V2 allows to achieve very high energy classes in new homes and to improve the class energy of the building /system on the existing ones. This increase the value per square meter of the home: an investment that pays off immediately. SPACE-SAVING SOLUTIONS The generators are well integrated to give an advantage in terms of installation and reduce overall space needs. MAGIS COMBO PLUS V2 (using specific accessories) can also be inserted inside of the SOLAR CONTAINER COMBO (recessed frame) or combined with the new SUPER TRIO system, both in the recessed frame...
Open the catalog to page 3TECHNICAL DATA MAIN FEATURES INTERNAL UNIT 72 plates R32 / water exchanger Stainless steel condensing module 10 litres expansion vessel Flowswitch that activates heat pump unit just if the water flow rate is enough Hydraulic group – 7 head m.w.c. low consumption circulator for heat pump unit (in the PLUS version can manage also DHW mode) Hydraulic group - 7 head m.w.c. low consumption circulator for condensing internal unit circuit New PCB prearranged to manage 3 zones, one direct and two mixed temperature System Controller (optional) to manage systems with more zones Standard shut off...
Open the catalog to page 4TECHNICAL DATA MAIN FEATURES EXTERNAL UNIT (AUDAX PRO V2) Inverter technology rotative compressor Preloaded refrigerant GAS R32 Shut off knobs R32 as standard Air finned heat exchanger (with single fan) Electronic lamination valve bi-flow 4-way valve for cycle inversion Heating and cooling operation (reversible) Possible installation outdoor without protection
Open the catalog to page 5SYSTEM EXAMPLE Buffer tank (to be dimensioned) Diverter valve for heating/cooling switching Wall-hung hydronic fancoil HYDRO 3 Water supply network EXAMPLE OF CONFIGURATION FOR MAGIS COMBO V2 IN THE REPLACING OF AN OLD EXISTING PLANT Installation suggested even in case of replacing existing gas boiler in a plant with fancoils or with radiators operating with medium temperature. MAGIS COMBO V2 can manage a three-way valve to heat the room with radiant panels or radiators and to cool with fancoils. Heating mode MAGIS COMBO V2 is switched on by a request from the plant. If the time required to...
Open the catalog to page 6SYSTEM EXAMPLE MAGIS COMBO PLUS V2 Photovoltaic inverter (with output contact for photovoltaic production) Photovoltaic panel DHW Thermostatic mixing valve DHW storage tank OMNISTOR Storage tank NTC probe (as standard) Safety inlet kit (not included) Buffer tank (to be dimensioned) Distribution manifold kit (1 direct and 1 mixed zone) HYDRO FS floor standing hydronic fancoil M Water supply network 10 EXAMPLE OF CONFIGURATION FOR MAGIS COMBO PLUS V2 WITH TWO SYSTEM ZONES AND PHV SYSTEM Ideal installation in new homes to achieve high energy efficiency rating and large % of power from...
Open the catalog to page 7TECHNICAL DATA Energetic class in heating at 55 °C Energetic class in heating at 35 °C Energetic class DHW/load profile Technical characteristics Heating capacity (system water 35 °C) Heating capacity (system water 45 °C) Heating capacity (system water 55 °C) Flow temperature range (C.H.) Outside air temperature range (C.H.) Cooling capacity (system water 18 °C) Cooling capacity (system water 7 °C) Flow temperature range (cooling) Outside air temperature range (cooling) EER (system water 18 °C) EER (system water 7 °C) Power supply Maximum power absorbed Condensing unit weight (empty) DATA...
Open the catalog to page 8TECHNICAL DATA Technical characteristics MAGIS COMBO 4 PLUS V2 MAGIS COMBO 6 PLUS V2 MAGIS COMBO 9 PLUS V2 Energetic class in heating at 55 °C Energetic class in heating at 35 °C g Heating capacity (system water 35 °C) Heating capacity (system water 45 °C) Heating capacity (system water 55 °C) Flow temperature range (C.H.) Outside air temperature range (C.H.) Cooling capacity (system water 18 °C) Cooling capacity (system water 7 °C) Flow temperature range (cooling) Outside air temperature range (cooling) Power supply Maximum power absorbed Condensing unit weight (empty) DATA REFERRED TO...
Open the catalog to page 9Electrical connection Liquid refrigerant GP Gas refrigerant AC Domestic hot water outlet Domestic cold water inlet Condensate drain (minimum internal diameter 13 mm) System return System flow Hydraulic connections MAGIS COMBO PLUS V2 440 115 Electrical connection Liquid refrigerant GP Gas refrigerant RU Return storage tank MU Flow storage tank RR System filling Condensate drain (minimum internal diameter 13 mm) System return System flow Hydraulic connections To ensure correct installation of internal unit, the air inlet/flue outlet pipes kit must be sele
Open the catalog to page 10External unit AUDAX PRO 4/6 V2 for MAGIS COMBO/PLUS V2 Hydraulic connections R32 GP (gas refrigerant) External unit AUDAX PRO 9 V2 for MAGIS COMBO/PLUS V2 Hydraulic connections R32 GP (gas refrigerant) ⁄ ” (15,88 mm)
Open the catalog to page 11TECHNICAL DATA Minimum distances for AUDAX PRO V2 installation TECHNICAL NOTE: System minimum water content: To facilitate proper execution of the heat pump defrost cycles, a minimum water content in the system is required, which must be 30 litres for all kinds of system. So attention must be paid to the systems divided over several zones, where the water content available to the machine changes continuously. This is why it may be necessary to provide a heating flywheel that guarantees normal operation with systems divided into zones (with variable water content in circulation). This...
Open the catalog to page 12All Immergas catalogs and technical brochures
-
SUPER TRIO
24 Pages
-
FANCOIL UNITS
20 Pages
-
VICTRIX PRO 2 ErP
94 Pages
-
AUDAX
114 Pages
-
CATALOGUE
216 Pages
-
LUXOR
16 Pages
-
VICTRIX ZEUS 25
12 Pages
-
VICTRIX TERA
12 Pages
-
WATER HEATERS
16 Pages
-
CATALOGUE_2018
200 Pages
-
VICTRIX EXA ErP range
16 Pages
-
VICTRIX MAIOR TT range
9 Pages
-
HEAT PUMPS
60 Pages
-
CATALOGUE 2018
176 Pages
-
VICTRIX PRO RANGE
28 Pages
-
RAPAX V2
8 Pages
-
MAGIS COMBO
20 Pages
-
Catalogue 2016
71 Pages
-
Heat Pumps_2016
21 Pages
Archived catalogs
-
THERMAL SOLAR SYSTEMS
84 Pages
-
CATALOGUE_2016
140 Pages
-
HEAT PUMPS
40 Pages
-
Thermal solar systems
45 Pages