Product catalog summary
Overview: The MAGIS COMBO V2 is a versatile hybrid heat pump system designed for heating, cooling, and hot water production. It features an internal condensing unit and is available in three single-phase versions (4, 6, and 9 kW) using eco-friendly refrigerant R32. The system is compact, energy-efficient, and suitable for both new homes with high insulation and for replacing older systems.
Specifications: The internal unit includes a condensing generator with capacities of 27.3 kW for hot water and 24 kW for heating, along with a hydronic module. The external unit, AUDAX PRO V2, incorporates inverter technology and a rotative compressor, preloaded with R32 refrigerant. It supports heating up to 80°C and is compatible with solar thermal systems.
Versions:
  • MAGIS COMBO V2 (Combi Version): Connectable to a separate storage tank for solar thermal integration.
  • MAGIS COMBO PLUS V2 (Heating Only Version): Designed for use with a separate storage tank for domestic hot water.
Energy Efficiency: The system achieves high energy classes (A++/A+++) and can enhance the energy class of existing buildings. It is optimized for integration with photovoltaic systems to maximize energy savings.
Technical Features:
  • Internal unit: 72 plates R32/water exchanger, stainless steel condensing module, 10-liter expansion vessel, and low consumption circulators.
  • External unit: Air finned heat exchanger, electronic lamination valve, and reversible operation for heating and cooling.
Installation and Configuration: Suitable for replacing existing gas boilers, the system can manage multiple zones with different temperature requirements and requires a minimum water content of 30 liters for optimal operation.
Technical Data: Detailed specifications include heating and cooling capacities, COP and EER values, power supply requirements, and weight for each model version. The system supports a wide range of operating temperatures and pressures.
Graphical Data: Flow rate/head graphs are provided for both the condensing boiler circuit and the heat pump circuit, illustrating pump consumption and system head at various flow rates.
Technical Data Overview: The document provides detailed technical specifications and options for the MAGIS COMBO/PLUS V2 heating system and its accessories, emphasizing the importance of combining the system with heat regulation devices to improve seasonal energy efficiency.
Flow Rate and Pump Consumption: Graphs illustrate the relationship between flow rate, head, and pump consumption at different speeds, showing proportional and constant head settings.
Heat Regulation Devices: Several devices, including modulating and ON-OFF chronothermostats, are listed, each contributing to energy efficiency improvements. Temperature control classes and their impact on seasonal space heating energy efficiency are specified.
Installation Kits and Accessories: A variety of kits are available to enhance the system's functionality, including relay board kits, safety thermostat kits, and Wi-Fi interface kits, designed to improve adaptability and efficiency.
Hydronic Fancoils and Accessories: Different models of hydronic fancoils, both floor-standing and wall/ceiling built-in, are listed along with their respective codes. Additional accessories like smart touch wall controllers and thermoregulation kits are also mentioned.
Storage Tank Units: OMNISTOR and UB INOX storage tanks are described, highlighting their stainless steel construction and efficiency class. These tanks are suitable for domestic hot water and can be connected to heat pumps.
Option Kits: Various option kits are available for specific installations, such as solar kits, dehumidifier kits, and connection kits for different configurations, enhancing the system's versatility and efficiency.
Ventilation Units: The ZENITAIR-MONO ventilation unit is introduced, featuring bidirectional airflow, heat recovery, and remote control capabilities, designed for easy installation and integration with hybrid systems.
Company Information: Immergas S.p.A., based in Italy, is a certified company under UNI EN ISO 9001:2015, specializing in the design, manufacture, and post-sale assistance of gas boilers and related accessories.
See more

Catalog excerpts

MAGIS COMBO V2-1

Hybrid heat pump HYBRID HEAT PUMPS

 Open the catalog to page 1
MAGIS COMBO V2-2

Heat pump and condensing: the intelligence and efficiency of hybrids MAGIS COMBO V2 is the new hybrid heat pump that heats, cools and produces hot water with an internal condensing unit designed to meet the highest demands. The new outdoor condensing unit is available in 3 single-phase versions: 4, 6 and 9 kW with refrigerant R32 (the most ecological) that guarantees high efficiency in all operating conditions. The internal unit is equipped with a condensing generator (27,3 kW for hot water production and 24 kW for heating) and an integrated hydronic module that controls the exchange of energy...

 Open the catalog to page 2
MAGIS COMBO V2-3

MORE VALUE TO PROPERTY MAGIS COMBO V2 allows to achieve very high energy classes in new homes and to improve the class energy of the building /system on the existing ones. This increase the value per square meter of the home: an investment that pays off immediately. SPACE-SAVING SOLUTIONS The generators are well integrated to give an advantage in terms of installation and reduce overall space needs. MAGIS COMBO PLUS V2 (using specific accessories) can also be inserted inside of the SOLAR CONTAINER COMBO (recessed frame) or combined with the new SUPER TRIO system, both in the recessed frame (CONTAINER...

 Open the catalog to page 3
MAGIS COMBO V2-4

TECHNICAL DATA MAIN FEATURES INTERNAL UNIT 72 plates R32 / water exchanger Stainless steel condensing module 10 litres expansion vessel Flowswitch that activates heat pump unit just if the water flow rate is enough Hydraulic group – 7 head m.w.c. low consumption circulator for heat pump unit (in the PLUS version can manage also DHW mode) Hydraulic group - 7 head m.w.c. low consumption circulator for condensing internal unit circuit New PCB prearranged to manage 3 zones, one direct and two mixed temperature System Controller (optional) to manage systems with more zones Standard shut off knobs...

 Open the catalog to page 4
MAGIS COMBO V2-5

TECHNICAL DATA MAIN FEATURES EXTERNAL UNIT (AUDAX PRO V2) Inverter technology rotative compressor Preloaded refrigerant GAS R32 Shut off knobs R32 as standard Air finned heat exchanger (with single fan) Electronic lamination valve bi-flow 4-way valve for cycle inversion Heating and cooling operation (reversible) Possible installation outdoor without protection

 Open the catalog to page 5
MAGIS COMBO V2-6

SYSTEM EXAMPLE Buffer tank (to be dimensioned) Diverter valve for heating/cooling switching Wall-hung hydronic fancoil HYDRO 3 Water supply network EXAMPLE OF CONFIGURATION FOR MAGIS COMBO V2 IN THE REPLACING OF AN OLD EXISTING PLANT Installation suggested even in case of replacing existing gas boiler in a plant with fancoils or with radiators operating with medium temperature. MAGIS COMBO V2 can manage a three-way valve to heat the room with radiant panels or radiators and to cool with fancoils. Heating mode MAGIS COMBO V2 is switched on by a request from the plant. If the time required to reach...

 Open the catalog to page 6
MAGIS COMBO V2-7

SYSTEM EXAMPLE MAGIS COMBO PLUS V2 Photovoltaic inverter (with output contact for photovoltaic production) Photovoltaic panel DHW Thermostatic mixing valve DHW storage tank OMNISTOR Storage tank NTC probe (as standard) Safety inlet kit (not included) Buffer tank (to be dimensioned) Distribution manifold kit (1 direct and 1 mixed zone) HYDRO FS floor standing hydronic fancoil M Water supply network 10 EXAMPLE OF CONFIGURATION FOR MAGIS COMBO PLUS V2 WITH TWO SYSTEM ZONES AND PHV SYSTEM Ideal installation in new homes to achieve high energy efficiency rating and large % of power from Renewable...

 Open the catalog to page 7
MAGIS COMBO V2-8

TECHNICAL DATA Energetic class in heating at 55 °C Energetic class in heating at 35 °C Energetic class DHW/load profile Technical characteristics Heating capacity (system water 35 °C) Heating capacity (system water 45 °C) Heating capacity (system water 55 °C) Flow temperature range (C.H.) Outside air temperature range (C.H.) Cooling capacity (system water 18 °C) Cooling capacity (system water 7 °C) Flow temperature range (cooling) Outside air temperature range (cooling) EER (system water 18 °C) EER (system water 7 °C) Power supply Maximum power absorbed Condensing unit weight (empty) DATA REFERRED...

 Open the catalog to page 8
MAGIS COMBO V2-9

TECHNICAL DATA Technical characteristics MAGIS COMBO 4 PLUS V2 MAGIS COMBO 6 PLUS V2 MAGIS COMBO 9 PLUS V2 Energetic class in heating at 55 °C Energetic class in heating at 35 °C g Heating capacity (system water 35 °C) Heating capacity (system water 45 °C) Heating capacity (system water 55 °C) Flow temperature range (C.H.) Outside air temperature range (C.H.) Cooling capacity (system water 18 °C) Cooling capacity (system water 7 °C) Flow temperature range (cooling) Outside air temperature range (cooling) Power supply Maximum power absorbed Condensing unit weight (empty) DATA REFERRED TO INTERNAL...

 Open the catalog to page 9
MAGIS COMBO V2-10

Electrical connection Liquid refrigerant GP Gas refrigerant AC Domestic hot water outlet Domestic cold water inlet Condensate drain (minimum internal diameter 13 mm) System return System flow Hydraulic connections MAGIS COMBO PLUS V2 440 115 Electrical connection Liquid refrigerant GP Gas refrigerant RU Return storage tank MU Flow storage tank RR System filling Condensate drain (minimum internal diameter 13 mm) System return System flow Hydraulic connections To ensure correct installation of internal unit, the air inlet/flue outlet pipes kit must be sele

 Open the catalog to page 10
MAGIS COMBO V2-11

External unit AUDAX PRO 4/6 V2 for MAGIS COMBO/PLUS V2 Hydraulic connections R32 GP (gas refrigerant) External unit AUDAX PRO 9 V2 for MAGIS COMBO/PLUS V2 Hydraulic connections R32 GP (gas refrigerant) ⁄ ” (15,88 mm)

 Open the catalog to page 11
MAGIS COMBO V2-12

TECHNICAL DATA Minimum distances for AUDAX PRO V2 installation TECHNICAL NOTE: System minimum water content: To facilitate proper execution of the heat pump defrost cycles, a minimum water content in the system is required, which must be 30 litres for all kinds of system. So attention must be paid to the systems divided over several zones, where the water content available to the machine changes continuously. This is why it may be necessary to provide a heating flywheel that guarantees normal operation with systems divided into zones (with variable water content in circulation). This minimum...

 Open the catalog to page 12

All Immergas catalogs and technical brochures

  1. SUPER TRIO

    24  Pages

  2. FANCOIL UNITS

    20  Pages

  3. AUDAX

    114  Pages

  4. CATALOGUE

    216  Pages

  5. LUXOR

    16  Pages

  6. VICTRIX ZEUS 25

    12  Pages

  7. VICTRIX TERA

    12  Pages

  8. WATER HEATERS

    16  Pages

  9. CATALOGUE_2018

    200  Pages

  10. HEAT PUMPS_2019

    60  Pages

  11. CATALOGUE 2018

    176  Pages

  12. RAPAX V2

    8  Pages

  13. MAGIS COMBO

    20  Pages

  14. Catalogue 2016

    71  Pages

Archived catalogs

  1. Heat Pumps_2016

    21  Pages

  2. CATALOGUE_2016

    140  Pages

  3. HEAT PUMPS

    40  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.