HEAT PUMPS HEAT PUMPS Enbloc solutions Split type solutions
Open the catalog to page 1ENERGY LABEL AND ErP REGULATIONS WE ARE READY TO DO OUR BIT FOR THE ENVIRONMENT We are talking about a very important European Union directive, an effective strategy that will drive to in reduced pollution and therefore improve the life of citizens all over Europe. The ErP directive (2009/125/CE) - the acronym stands for “Energy Related Products” - assesses very precise guidelines for design and the manufacturing of eco-compatible products and defines the minimum mandatory requirements for the efficiency and environmental performance of all power-consuming devices. Supplier indication Space heating...
Open the catalog to page 2HEAT PUMPS NEW HEAT PUMP RANGE p. 5 ENBLOC SOLUTIONS SPLIT TYPE SOLUTIONS DOMESTIC HOT WATER SOLUTIONS During the life of a product, performance is influenced by external factors, e.g. water hardness, atmospheric agents, system limiting, etc The published data refers to newproducts correctly installed and used, in accordance with local regulations. N.B. we recommend regular perio- New heat pump range Clean, safe energy for heating and cooling Heat pumps are one of the best environment-friendly solutions for housing and office buildings climatization, both in the summerand in the winter period....
Open the catalog to page 3AUDAX TOP ErP Air/water inverter heat pumps WIDE RANGE OF PRODUCTS Heat pumps are among the best solutions for environment-friendly climate control in homes and offices, summer and winter. The new Immergas range is dedicated to professionals who are looking for systems with a strong use of renewable energy, integrated or hybrid systems that can provide great comfort while complying with regulations. AUDAX TOP ErP is the name of our new self-contained air/water units. Inverter technology modulates power, reduces power absorption and delivers high performance. It features a low-consumption circulator...
Open the catalog to page 4TECHNICAL DATA USER-FRIENDLY INTERFACE The standard control panel not only displays operation diagnostics but also serves as weekly thermostat for managing heating/ cooling with room temperature/humidity sensor in stand-alone applications. Easy connections by only 2 BUS cables and 2 power supply cables to connect It at AUDAX TOP ErP. The control panel doesn’t need battery. The control panel lets you: • set room temperature (comfort/economy) • set time and climate curve (in heating and cooling mode) • view error codes for the heat pump INTEGRATED SYSTEMS Air-water heat pumps can be used as single...
Open the catalog to page 5TECHNICAL DATA Technical characteristics PRODUCT INFORMATION Code heat pump Heating capacity (system water 35 °C) Heating capacity (system water 45 °C) Flow temperature range (CH) Outside air temperature range (CH) Heating min/max (system water 35 °C) Cooling capacity (system water 7 °C) Flow temperature range (cooling) Outside air temperature range (cooling) In accordance with the ELD directive (in conformity with regulation 811/2013), we include the label of each heat pump to enable customers to evaluate the products. The labels are shown in the documentation accompanying the units as well...
Open the catalog to page 6TECHNICAL DATA Flow rate/head graph AUDAX TOP 6 ErP Available head in the system: 75 minimum 70 medium 65 60 maximum Water inlet Water outlet Water drain Flow rate/head graph AUDAX TOP 8 ErP Water inlet Water outlet Flow rate/head graph AUDAX TOP 12/16 ErP Water drain Water outlet Water inlet Water inlet Water outlet
Open the catalog to page 7TECHNICAL DATA CLIMATIC REGULATION Minimum distances for AUDAX TOP ErP installation CRONO 7 (weekly digital chronothermostat) Solar collector probe Storage tank NTC probe * CRONO 7 WIRELESS (wireless weekly digital chronothermostat) Room hygrostat** Temperature/humidity active sensor kit 300 System controller expansion kit * System controller * Standard accessory in the hydraulic kits code 3.021527 and 3.021528. * * To be used with radiant systems that also work in cooling mode. OPTION KITS Distribution manifold kit for 1 direct and 2 mixed temperature zones ** Distribution manifold kit for 2...
Open the catalog to page 8Split type reversible air/water heat pumps composed by an outdoor condensing unit and an indoor hydronic unit IDEAL SOLUTIONS FOR NEW HOME The word “PRO” indicates that the device is for professional use i.e. for qualified installers (with F-GAS Certification) who will make the refrigerator connections between the 2 units. Available in three versions (5, 8 and 10 kW), these system solutions are ideal for new residential buildings with very high energy class even in areas with extremely low external temperature. IDEAL PROTECTION FROM FREEZING The water circuit is completely protected from freezing,...
Open the catalog to page 9TECHNICAL DATA TECHNICAL DATA INTEGRATED SYSTEM EXAMPLE MAIN FEATURES HYDRONIC UNIT • 48 plates R410A / water exchanger • 12 litres expansion vessel • Flowmeter and water manifold prearranged for Additional 3 kW electric resistance kit (optional) • Hydraulic group - 7 mwc low consumption circulator • 3-ways diverte valve for connection at DHW storage tank • PCB prearranged to manage 2 zones (without System controller), 1 direct and 1 mixed (heating and cooling) • System Controller (optional) to manage an integrated system with a gas bolier • Standard shut off knobs with ¾” filter for water circuit...
Open the catalog to page 10INTEGRATED SYSTEM EXAMPLE TECHNICAL DATA Condensing unit AUDAX PRO (external probe as standard) Hydronic unit VICTRIX MAIOR X TT ErP boiler Technical characteristics System controller Solar pump station and safety valve Liquid connection pipes R410A Solar expansion vessel Flat-Plate solar collectors CP4 M Solar collector probe Max length refrigerant pipes* Thermostatic mixing valve DHW storage tank INOXSTOR ErP Heating capacity (system water 35 °C) Storage tank NTC probe (upper part) Heating capacity (system water 45 °C) Storage tank NTC probe (lower part) Heating capacity (system water 55 °C)...
Open the catalog to page 11Hydronic unit Condensing unit AUDAX PRO 8/10 Key Liquid refrigerant Gas refrigerant Flow storage tank Return storage tank System return System flow Filling system Condensing unit AUDAX PRO 5 610 Minimum distances for AUDAX PRO installation