AUDAX-1

HEAT PUMPS AUDAX AND INTEGRATED SYSTEMS with reversible inverter mono-phase and three-phase air-water Heat Pumps

 Open the catalog to page 1
AUDAX-4

AUDAX DESCRIPTION A range of air/water reversible heat pumps with inverter technology. The mono-phase versions are available with AUDAX 6, AUDAX 8, AUDAX 12 and AUDAX 16 models to fulfil central heating and cooling requirements for homes, offices, shops, etc...; while the three-phase versions are available with AUDAX 16, AUDAX 18 and AUDAX 21 models to fulfil central heating and cooling requirements for large domestic systems (newly built large homes such as duplexes, three-unit houses, condominiums), as well as offices, shops, artisan activities, etc.. These appliances are distinguished for...

 Open the catalog to page 4
AUDAX-5

6 kW, 8 kW, 12 kW and 16 kW mono-phase inverter air/water heat pumps for winter and summer air conditioning. The galvanised steel structure makes the machines particularly suitable for outdoor installation. Main components: • Control Panel - standard supply - which enables you to program the machine and also functions as a room temperature/ humidity sensor. It also displays the error codes in the event of malfunctions; • R410A refrigerant gas (pre-loaded in the machine); • Twin Rotary compressor with hybrid inverter activation in direct current with PAM (Pulse Amplitude Modulation) and PWM (Pulse...

 Open the catalog to page 5
AUDAX-6

AUDAX 16 - 18 - 21 (THREE-PHASE) FEATURES 16 kW, 18 kW and 21 kW three-phase inverter air/water heat pump for winter and summer air conditioning. The galvanised steel structure makes the machines particularly suitable for outdoor installation. Main components: • Control Panel - standard supply - which enables you to program the machine and also functions as a room temperature/ humidity sensor. It also displays the error codes in the event of malfunctions; • R410A refrigerant gas (pre-loaded in the machine); • Twin Rotary compressor with hybrid inverter activation in direct current with PAM (Pulse...

 Open the catalog to page 6
AUDAX-7

AUDAX and Integrated Systems 4 INTEGRATED SYSTEM FOR AIR CONDITIONING AND D.H.W. PRODUCTION Comprised of a boiler – solar heating – heat pump and possibly photovoltaic – etc, they are the natural evolution of air-conditioning systems: with very high seasonal efficiency, low energy consumption and reduced polluting emissions. They are engineering solutions that can be perfectly integrated with each other, which allow to attain maximum benefit from the various energy production systems on the basis of the respective efficiency parameters. For the entire system to operate correctly, Immergas offers...

 Open the catalog to page 7
AUDAX-8

AUDAX and Integrated Systems reach full operation: when a maximum time is exceeded (can be set differently between C.H. and D.H.W.) for the heat pump to reach the flowT, the boiler or integrative electrical resistance is started. It is also possible to choose the integration operation method (boiler/resistance) between simultaneous or alternative Heat pump. In all cases where radiant panels are also included for summer cooling, alongside dehumidifiers (see previous picture), the System Manager will also monitor the dew point through the installation of room probes (Immergas). Thanks to this intelligent...

 Open the catalog to page 8
AUDAX-9

HEAT ADJUSTMENT WITH AUDAX CONTROL PANEL IN STANDALONE APPLICATIONS (SETTING AND LOGIC OPERATION) The Control panel (standard supply with AUDAX) enables programming of several operating options and relative temperature/ humidity control of the system. For example, the Control panel acquires data regarding outdoor temperature (from the external probe), system flow temperature (regarding the pre-set climatic curve), and also the room's humidity percentage. The standard Control panel supplied is connected to a specific terminal block on AUDAX, which enables you to program the machine and also functions...

 Open the catalog to page 9
AUDAX-10

PROGRAMMING MENU 1 - Main parameters switch with button to confirm and save data 2 - Left context button 3 - Right context button 4 - Display Once the device is powered, it goes into the status prior to switchoff. Press the “Modo” (Mode) (2) button to cyclically select the desired mode amongst those available. Depending on the system's configuration, the main screen displays various information regarding the system. Press the “Menu” (3) button to access a list of variables that enable you to customise use of the system. To browse the menus, which can be accessed by pressing the relative “RH”...

 Open the catalog to page 10
AUDAX-11

USER PROGRAMMING MENU Zone Set Point Menu Menu item Set Central heating comfort Room temperature in central heating zone Comfort mode Set Central heating economy Room temperature in central heating zone Economy mode Set central heating flow Room temperature in cooling zone Comfort mode Room temperature in cooling zone Economy mode Flow temperature in room zone cooling mode Central heating flow offset Set cooling flow Cooling flow offset Flow temperature in room zone central heating mode Offset temperature for central heating zone Offset temperature for cooling zone DHW Set point Menu Menu item...

 Open the catalog to page 11
AUDAX-12

AUDAX Anomalies Log Menu Description Displays the history log of the last 10 anomalies Assistance Menu Menu item Password protected menu dedicated to a qualified technician Language Menu Menu item Language Description Defines the control panel operation language

 Open the catalog to page 12
AUDAX-13

MAINTENANCE TECHNICIAN PROGRAMMING MENU Assistance Menu Menu item Zone Definition Zone system sub-menu settings System definition Sub-menu to define the devices connected to the system Sub-menu to set the device's configuration Central heating thermoregulation setting sub-menu Cooling thermoregulation setting sub-menu Device configuration Central heating temperature control Cooling temperature control Parameters thermoregulation Restore default settings Manual operating parameters sub-menu Heat pump operating parameters sub-menu Heat pump Parameters thermoregulation setting sub-menu System integration...

 Open the catalog to page 13
AUDAX-14

AUDAX Assistance Menu -> Device configuration Menu item Heat pump control Slave address Description Setting “Yes”, the default control panel supplied manages the heat pump. Setting “No”, the control panel does not control the heat pump and must be coupled with other Immergas systems (for example, TRIO, MAGIS HERCULES, Or System manager). If “No” is set, it displays another item “slave address”. N.B.: if it is erroneously set to “No”, it is still possible to change the selection. Address to configure according to the zone where the device is installed (e.g.: zone 1 = 41, zone 2 = 42, zone 3 =...

 Open the catalog to page 14

All Immergas catalogs and technical brochures

  1. SUPER TRIO

    24  Pages

  2. FANCOIL UNITS

    20  Pages

  3. MAGIS COMBO V2

    36  Pages

  4. CATALOGUE

    216  Pages

  5. LUXOR

    16  Pages

  6. VICTRIX ZEUS 25

    12  Pages

  7. VICTRIX TERA

    12  Pages

  8. WATER HEATERS

    16  Pages

  9. CATALOGUE_2018

    200  Pages

  10. HEAT PUMPS_2019

    60  Pages

  11. CATALOGUE 2018

    176  Pages

  12. RAPAX V2

    8  Pages

  13. MAGIS COMBO

    20  Pages

  14. Catalogue 2016

    71  Pages

Archived catalogs

  1. Heat Pumps_2016

    21  Pages

  2. CATALOGUE_2016

    140  Pages

  3. HEAT PUMPS

    40  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.