INSTRUCTION FOR INSTALLATION AND USE - GARANTY You have just acquired this radiant radiator FANMIX And we thank you for your choice. This device has been studied, designed and realized with care, In order to give you full satisfaction. NO-135001A - ILO INSTRUCTION MANUAL ECODESIGN UK This product cannot be used as a primary heater

Open the catalog to page 1
FANMIX - 2

Markings & Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 General Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Precautions for use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installation of radiator FANMIX . . . . . . . . . . . . . . . . . . . . . . . . 6 Composition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Tools required for Installation...

Open the catalog to page 2
FANMIX - 3

Markings and indications FANMIX 400 x 1200 reference : THERMAL POWER Nominal Thermal Power Minimal Thermal Power ( indicative) Maximal Thermal Power (constant) At nominal thermal power At minimal thermal power Nominal Thermal Power Minimal Thermal Power ( indicative) Maximal Thermal Power (constant) At nominal thermal power At minimal thermal power Nominal Thermal Power Minimal Thermal Power ( indicative) Maximal Thermal Power (constant) At nominal thermal power At minimal thermal power Nominal Thermal Power Minimal Thermal Power ( indicative) Maximal Thermal Power (constant) At nominal...

Open the catalog to page 3
FANMIX - 4

General Instructions Before installing and using your FANMIX radiator, please read these instructions carefully and observe the following instructions : SAFETY INSTRUCTIONS The electrical connection must be carried out by a qualified electrician. The installation must be protected by a 25 or 30 mA differential circuit- breaker (NFC15-100 electrical safety standard). The power supply outage must be of omnipolar type (phase and neutral cut-off). The radiator FANMIX must be connected to the power supply (230V AC 50/60Hz) by an electrical circuit protected by an overcurrent circuit breaker16A...

Open the catalog to page 4
FANMIX - 5

For a bathroom installation, observe the zone of use in compliance with the protection index IP44: zones 2 and more Bath Volume Shower with receiver Volume Shower without receiver Volume IPPROTECTION ACCESSORIES Plug supplied by safety transformer Plug protected by 30mA RCD Low voltage (12 to 30V) Class II and RCD 30mA or Low voltage Plug protected by 30mA RCD The heater should not be placed directly below a power outlet. Thoroughly test the radiator before installation and ensure that no hot spots develop. Only use the radiator FANMIX for the recommended applications and with the FANMIX...

Open the catalog to page 5
FANMIX - 6

This device is not intended for use by persons (including children) with reduced physical, sensory or mental capacities, or persons without experience or knowledge, unless they have been By a person responsible for their safety, supervision or prior instructions relating to the use of the appliance and that the risks incurred have been apprehended. The radiator FANMIX is a certified device for its performance and safety. Caution : As with any heating appliance, some parts may become very hot and cause burns in case of prolonged contact. Particular attention must be paid to the presence of...

Open the catalog to page 6
FANMIX - 7

Installation of radiator FANMIX COMPOSITION The FANMIX extra-fine design radiator consists of: • From a tempered glass decorative surface, • From an aluminum heating film (patented), • A mounting system for an installation Horizontal • An electrical box and a radio receiver for proper operation of the thermostat Towel bars can be added To your radiator FANMIX before fixing it to the wall To turn it into a real towel dryer: ideal for your bathroom (accessories supplied separately). TOOLS REQUIRED FOR INSTALLATION Minimum tools required For installation Accessories not included: 4 screws and...

Open the catalog to page 7
FANMIX - 8

INSTALLATION AND FITTING To facilitate installation of your FANMIX radiator, a template is provided. It is represented on the back of the packaging (actual dimensions). • Reminder of drilling centers HORIZONTAL SPACING In mm FANMIX 400x1200 FANMIX 400x1800 FANMIX 600x1200 FANMIX 600x1800 VERTICAL SPACING In mm FANMIX 400x1200 FANMIX 400x1800 FANMIX 600x1200 FANMIX 600x1800 • Selection of radiator location Position the template on your wall to choose the ideal location of your radiator and rely on the indicated marks. Remember to keep a minimum distance around the product (at least 200 mm...

Open the catalog to page 8
FANMIX - 9

• Attaching the radiator to the wall Fix the 2 wall brackets with 4 dowels and 4 screws adapted to the material of your wall. Glue the 4 foam pads underneath each Hole as shown Position the radiator on the wall brackets By sliding it correctly into the holes. Lock the radiator the lateral safety screw provided. (Left or right of choice).

Open the catalog to page 9
FANMIX - 10

• Electrical connection Connect electrically. L = Phase (brown) N = Neutral (blue) The electrical connexion must be made with a IPX4 box , class II, in compliance with regulation. PILOT WIRE = FP (noir) Do not plug in if you are not connected to an automated system that manages the Pilot wire. Please go page 24 for more detailled information. Protect the supply line with a circuit breaker differential of 25 or 30 mA. Clean with a soft, damp cloth before heating. Switch on using the switch located on the side of the radiator..

Open the catalog to page 10
FANMIX - 11

Operation of the programmable wireless thermostat DESCRIPTION The heating column is managed by an autonomous radio frequency regulation system. It is composed of 2 elements ; the thermosthat and the reciever located inside the facade. The carton includes : The wireless thermostat 2 batteries AAA 2 feet for free installation of the thermostat 1 Connector board et 4 screws for wall mounting Quality certificate Characteristics: Dimensions (L/l/p in mm) : 135 / 87.5 / 23.2 Adjustment accuracy : ± 0.5°C Temperature min/max : 5~35°C Programmation 24/24 – 7J/7 Wall hanging or free-standing (hiding...