1. Catalogs
  2. IKO
  3. IKO Cold Gold Booklet

IKO Cold Gold Booklet

IKO Cold Gold Booklet
1 / 12 PagesView full catalog

IKO Cold Gold Booklet

Product catalog summary
Introduction
This document provides guidelines for the application of the COLD GOLD™ Cold-Applied Roofing System, highlighting its solvent-free, VOC-free, non-hazardous, and moisture-cured properties.
Products
  • IKO COLD GOLD™ Field Adhesive: Single component for horizontal surfaces with a maximum slope of 8%.
  • IKO COLD GOLD™ Flashing Cement: Two-part system for vertical and horizontal flashing surfaces.
Required Tools
Includes various trowels, a steel floor roller, a power drill with a paint mixer, and cleaning tools like mineral spirits.
Mixing Instructions
Mix products thoroughly for 3 to 4 minutes using an electric drill and paint mixer.
Application Procedures
  • Insulation and Protectoboard: Embed using 1/2” ribbons with specific patterns depending on the deck type.
  • Field Adhesive: Apply evenly with a 3/32” V-Notched trowel/squeegee.
  • Flashing Cement: Mix parts A & B, apply with a 3/16” V-Notched trowel, and ensure proper adhesion with a hand roller.
Field Membrane Application
Use specified Modiflex membranes and ensure proper rolling to remove air pockets.
Advantages
Features include being solvent-free, VOC-free, non-hazardous, moisture-cured, and applicable in a wide temperature range.
Installation Tips
Emphasizes proper membrane relaxation, back-rolling, tool cleaning, and correct mixing and application techniques.
Notes
Provides disclaimers about product specifications, liability, and the need for verification by architects or contractors.
See more

Catalog excerpts

IKO Cold Gold Booklet-1

COLD GOLDTM Cold-Applied Roofing System Application Booklet • Solvent-Free • VOC-Free • Non-Hazardous • Moisture-Cured • Good Initial Bond www.iko.com

 Open the catalog to page 1
IKO Cold Gold Booklet-2

Products IKO COLD GOLDTM Field Adhesive (Single Component) · To be used on the field only (horizontal surfaces 1/12 or 8% slope maximum.) For greater slopes, use Flashing Cement. IKO COLD GOLDTM Flashing cement (Two Part - A & B) · To be used on flashing (vertical and horizontal surfaces). Required Tools · 3/16” V-Notched Hand Trowel · Hand Roller (Flashing Cement) · T-Square · 3/32” V-Notched Hand Trowel/ · Chalk Line Squeegee (Field Adhesive) · Mineral Spirits · Steel Floor Roller (Min.75#- (for cleaning tools) Max 100#) · Broom · 1/2” Power Drill (9 AMP) · Roofing Knife c/w Paint Mixer 2 Cold...

 Open the catalog to page 2
IKO Cold Gold Booklet-3

Mixing (for all applications) · Mix product thoroughly with electric drill and paint mixer no less than 3 minutes, but no more than 4 minutes. Insulation – Ribbon Application Firmly embed insulation in IKO Cold GoldTM Adhesive using 1/2” ribbons with subsequent ribbons running 12” on centre, parallel to top of steel deck flutes or “S” pattern on non-metal decks. (approx. 1,000 sq. ft. per 18.7 L) Cold Applied Roofing Systems 3

 Open the catalog to page 3
IKO Cold Gold Booklet-4

FIELD ADHESIVE 3/32” V-notched 5 GALLON (18.7 L) PAIL trowel/Squeegee · Apply evenly using a 3/32” V-Notched trowel/ squeegee. · Trowel must be perfectly vertical. · DO NOT APPLY THICKER THAN DIRECTED. Protectoboard - rIBBON Application Firmly embed Protectoboard in IKO Cold GoldTM Adhesive using 1/2” ribbons with subsequent ribbons running 12” on centre, or “S” pattern on non-metal decks. (approx. 1,000 sq. ft. per 18.7 L) 4 Cold GoldTM

 Open the catalog to page 4
IKO Cold Gold Booklet-5

Field Membrane Application - Membranes Used field · Modiflex MF-95-SS-Base (147 sq. ft./roll) (Fiberglass reinforcement mat) · Modiflex Cold GoldTM Base (147 sq. ft./roll) (Polyester reinforcement mat) · Modiflex MP-180-Cap (98 sq. ft./roll) · Modiflex Prevent MP-180-Cap (Class A) (98 sq. ft./roll) FLASHINGs · Modiflex Cold GoldTM Base (147 sq. ft./ roll) (Polyester reinforcement mat) · Modiflex MP-180-Cap (98 sq. ft./roll) · Modiflex Prevent MP-180-Cap (Class A) (98 sq. ft./roll) Rolling Rolling · Roll membrane using a 75 lb. to 100 lb. roller. · Ensure rolling is performed from centre of sheet...

 Open the catalog to page 5
IKO Cold Gold Booklet-6

Flashing Cement 3/16” V-notched trowel · Mix Part A & B – no less than 3 minutes but no more than 4 minutes. · Fully adhere in IKO Cold GoldTM Flashing Cement using 3/16” V-Notched trowel (coverage approximately 80 sq. ft per 7.5 L). · Ensure proper adhesive application; excessive adhesive may cause longer cure time. · Ensure proper adhesion by using a hand roller over the entire area. · Apply Flashing Cement to all inside and outside corners to form a liquid gusset. · Coat substrate only. · At room temperature, pot life will be approximately 90 minutes. IKO COLD GOLD™ FLASHING CEMENT Used for...

 Open the catalog to page 6
IKO Cold Gold Booklet-7

FLASHING CEMENT MIX PART A & B HAND ROLL IKO STANDARD FLASHING DETAIL ■ Minimum flashing height is 8" (203 mm) above the roof surface Base flashing 8" (203 mm) minimum past toe of cant strip and 1" (25 mm) less the height of cap flashing Maximum past toe of cant strip Base Sheet (Field) Cold Applied Roofing Systems

 Open the catalog to page 7
IKO Cold Gold Booklet-8

Advantages Features & Benefits · Solvent-Free: No pungent odors · Compatible with IKOTherm, and no fire hazard. Protectoboard and Modiflex Base/ · VOC-Free: No volatile compounds. Cap sheets, Modified Vapor · Non-Hazardous: Unrestricted Protector, Expanded polystyrene/ transport in North America. Extruded polystyrene. · Moisture-Cured: No solvents to · Substantial cure time in 48 hours “flash off” with a fast cure time. under ideal conditions. · Wide range of application temperatures: -10°C (14°F) to 40°C (104°F).* · Easy to apply (notched squeegee) and easy to clean up (mineral spirits). · NO...

 Open the catalog to page 8
IKO Cold Gold Booklet-9

Installation tips Don’t Forget To: · Relax membrane prior to use. · Back-roll membrane to ensure full bond. · Keep product warm until ready for use. · Use a 9 amp (minimum) drill for mixing. · Clean tools with mineral spirits. · Roll all materials after they are installed. · Ensure proper mixing no less than 3 minutes, but no more than 4 minutes. · Use the right size trowel: - 3/16” Flashings - 3/32” Field · Train all applicators. · Use the right amount of Cold GoldTM – too much material is not good! Cold Applied Roofing Systems 9

 Open the catalog to page 9
IKO Cold Gold Booklet-12

Thank you for considering IKO Premium Roofing products. For additional information on IKO’s full line of superior Commercial/Industrial Roofing and Waterproofing products please call: 1-888-766-2468, or visit our web site at: www.iko.com Note: The physical properties of the products described in this catalogue represent average typical results obtained by testing our products according to accepted industry test methods. These values are subject to normal manufacturing variations, and are supplied as a technical guideline only; they may be subject to change without notice. Current product specifications...

 Open the catalog to page 12

All IKO catalogs and technical brochures

  1. PO UK weight

    2  Pages

  2. ALU NF

    24  Pages

  3. IKO roofing

    29  Pages

  4. IKO enertherm

    32  Pages

  5. ProTecto