Introduction
This manual is intended for service technicians handling the installation and maintenance of Ice-O-Matic ICE Series cube ice machines. It emphasizes the importance of thoroughly understanding the manual before proceeding with any tasks. For unresolved issues, contact Ice-O-Matic's Technical Service Department.
Freight Claim Procedure
Shipments should be inspected immediately upon receipt. Visible damage must be noted on the freight bill and signed by the carrier's agent. Concealed damage requires a carrier inspection within 15 days of delivery.
Warranty
Ice-O-Matic provides a limited warranty covering parts and labor, varying by product type. The warranty is valid only if installation and maintenance are conducted by authorized personnel, with claims filed within 90 days of service.
Model and Serial Number Format
The serial number includes a date code, Ice-O-Matic identifier, and a sequential number, essential for machine identification.
Installation Guidelines
Proper installation is crucial for performance. Key points include maintaining ambient temperatures between 50°F and 100°F, water supply temperatures from 40°F to 100°F, and pressure between 20 psi and 60 psi. Ensure adequate air circulation and compliance with local codes for drain lines. Electrical connections must be made by a qualified electrician. Non-compliance may void warranties and reduce efficiency.
ENERGY STAR Qualified Models
Some Ice-O-Matic models are ENERGY STAR qualified, potentially offering rebates or incentives from local utility companies.
Installation Guidelines
Use 1/4 inch O.D. minimum tubing for the condenser line, ensure proper drain line diameter, attach the machine to the bin with provided hardware, avoid heat on plastic parts, connect power supply correctly, level the machine, and remove packaging materials. Follow Remote Condenser Installation Guidelines if applicable.
Remote Condenser Installation
Location limits include a maximum rise of 35 feet, drop of 15 feet, and line set length of 75 feet. Ambient temperatures should range from -20°F to 120°F. Use precharged refrigerant tubing and ensure proper routing. Roof attachment must comply with local codes.
Electrical and Plumbing Requirements
Models have specific electrical and plumbing needs. Some use thermostatic bin control instead of mechanical switches. Access to control boxes may require removing grill screws.
How the ICE Machine Works
The machine operates in freeze and harvest cycles. During freeze, water circulates over evaporators to form ice. Harvest involves purging water and using hot gas to release ice. Bin switches control operation based on ice levels.
Start-Up Procedure
Ensure the machine is level, check water levels, adjust water flow and valves, check ice formation, and verify bin control operation for proper shut-off.
General Maintenance
Regular maintenance is essential for performance. Adjustments to bin controls and timers may be needed. Follow specific procedures for different models.
Safety Precautions
Disconnect electrical supply before adjustments or repairs to prevent injury from moving parts.
Warranty Conditions
Failure to perform specified maintenance will void warranty coverage for related failures.
General Maintenance Procedure
Maintenance every 6 months includes cleaning the ice-making section, checking ice bridge thickness, cleaning the condenser, inspecting for leaks, adjusting water valves, checking electrical connections, oiling the fan motor, replacing the water filter, and ensuring even water distribution.
Cleaning and Sanitizing Instructions
Scheduled at least twice a year, cleaning involves removing the front panel, adding cleaner to the water trough, flushing the system, using a sanitizing solution, and discarding the first two ice harvests post-cleaning.
Stainless Steel Care
Clean stainless steel surfaces weekly with non-abrasive tools and avoid chlorine-based cleaners. Rinse thoroughly with clean water.
Winterizing Procedure
For winter, turn off the water supply, remove all ice, drain the water system, and use compressed air to clear water from the condenser in water-cooled machines.
Service History
A section is provided to record the model number, serial number, and installation date for tracking service history.
See more

Catalog excerpts

ICEU150, ICEU220 and ICEU300 Undercounter Series*-1

Installation, Start-Up and Maintenance Manual ICE SERIES CUBERS ICE0250 through ICE2100 Series* ICEU150, ICEU220 and ICEU300 Undercounter Series* ICE0320 and ICE0520 22 Inch Series* *INCLUDES 230/50/1 VOLT UNITS Ice-O-Matic 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081264-01 Date 11/08

 Open the catalog to page 1
ICEU150, ICEU220 and ICEU300 Undercounter Series*-3

ICE Series Introduction How To Use This Manual Ice-O-Matic provides this manual as an aid to the service technician in installation and maintenance of the ICE Series (electro-mechanical) cube ice machines. Do not attempt to perform installation, start-up or maintenance unless you have read and fully understand this manual. If at any time you encounter conditions that are not addressed in this manual, call, E-mail or write the Ice-O-Matic Service Department: Ice-O-Matic th 11100 E. 45 Ave. Denver, Co. 80239 Attn: Technical Service Department E-Mail: [email protected] Telephone Numbers...

 Open the catalog to page 3
ICEU150, ICEU220 and ICEU300 Undercounter Series*-4

ICE Series Table of Contents Introduction Page i Table of Contents Page ii Freight Claim Procedure Page iii Warranty Page iv Model Number and Serial Number Format Page 1 Installation Guidelines Page 2 Remote Condenser Guidelines Page 4 Electrical and Plumbing Requirements Page 6 How the Machine Works Page 13 Start-Up Procedure Page 14 General Maintenance Page 16 Cleaning Procedure Page 17 Cabinet Care Page 18 Winterizing Procedure Page 19 Maintenance Record Page 20 Page ii

 Open the catalog to page 4
ICEU150, ICEU220 and ICEU300 Undercounter Series*-5

ICE Series Freight Claim Procedure Freight Claims Important! Inspect Promptly This merchandise has been carefully inspected and packed in accordance with the carrier’s packing specifications. Responsibility for safe delivery has been assumed by the carrier. If loss or damage occurs, you as the consignee must file a claim with the carrier and hold the container for carrier’s inspection. Visible Loss or Damage Any external evidence of loss or damage must be fully described and noted on your freight bill or express receipt and signed by the carrier’s agent. The claim should be filed on a form available...

 Open the catalog to page 5
ICEU150, ICEU220 and ICEU300 Undercounter Series*-6

ICE Series Warranty Ice-O-Matic Parts and Labor Domestic & International Limited Warranty Mile High Equipment LLC (the “Company”) warrants Ice-O-Matic brand ice machines, ice dispensers, remote condensers, water filters, and ice storage bins to the end customer against defects in material and factory workmanship for the following: • Cube ice machines,”GEM” model compressed ice machines ,” MFI” model flake ice machines and remote condensers. - Thirty-six (36) months parts and labor • “EF” and “EMF” model flake ice machines - Twenty-four (24) months parts and labor • CD model dispensers - Thirty-six...

 Open the catalog to page 6
ICEU150, ICEU220 and ICEU300 Undercounter Series*-7

ICE Series Model and Serial Number Format Model and Serial Number Format Note: Sample of Serial Number Data Plate The serial number format and machine specifics are detailed on the data plate. ICE 040 0 H A 2 Design Level Condenser Type: A=Air, W=Water, R=Remote Cube Size: H=Half, F=Full Voltage: 0=115V, 6=230V/60Hz. 5=240V/50Hz. Approximate Production in 24 hours @70°FAir/50°FWater Series: Environmental Cuber (Uses HFC Refrigerant) This format is 14 characters long and begins with a date code followed by the Ice-O-Matic identifier, and then a sequential number. This is an entirely numerical...

 Open the catalog to page 7
ICEU150, ICEU220 and ICEU300 Undercounter Series*-8

ICE Series Installation Guidelines Installation Guidelines For proper operation of the Ice-O-Matic ice machine, the following installation guidelines must be followed. Failure to do so may result in loss of production capacity, premature part failures, and may void all warranties. Reference the installation parameters prior to installing the machine: Ambient Operating Temperatures Minimum Operating Temperature: 50°F (10°C) Maximum Operating Temperature 100°F (38°C), 110°F (43°C) on 50 Hz. Models. Note: Ice-O-Matic icemakers and dispensers are not approved for outdoor installation. Incoming Water...

 Open the catalog to page 8
ICEU150, ICEU220 and ICEU300 Undercounter Series*-9

ICE Series Installation Guidelines Secure the machine on top of the bin or dispenser. Attach the ice machine to the bin with the mounting straps provided with the bin or dispenser. Insure that the back of the ice machine is flush with the back of the bin. Proper functioning of the bin door requires the bin door, when it is opened, to be in a stable position. If the ice machine is too far forward on the bin, the opened door may not be stable, resulting in an unexpected closing of the bin door. If the ice machine is to be mounted on a bin or dispenser other than an Ice-O-Matic, refer to the manufacturers...

 Open the catalog to page 9
ICEU150, ICEU220 and ICEU300 Undercounter Series*-10

ICE Series Remote Condenser Guidelines Remote Condenser Installation For proper operation of the Ice-O-Matic ice machine, the following installation guidelines must be followed. Failure to do so may result in loss of production capacity, premature part failure, and may void all warranties. Use the following for planning the placement of the remote condenser relative to the ice machine. Location Limits: Remote condenser location must not exceed ANY of the following: ● Maximum rise from the ice machine to the remote condenser is 35 physical feet. ● Maximum drop from the ice machine to the remote...

 Open the catalog to page 10
ICEU150, ICEU220 and ICEU300 Undercounter Series*-11

ICE Series Remote Condenser Guidelines The following remote ice makers incorporate the mixing valve in the condenser. This configuration allows up to a 100 foot calculated remote line set run. Reference the diagram below to calculate the maximum 100 foot line set run. ICE Machine Model Number ICE2106/7R4 ICE1806/7R4 ICE1506HR3 ICE1405/6/7R4 ICE1006R3 ICE806R3 ICE0606R5 ICE0500R5 Remote Condenser Model Number VRC5061B VRC5061B VRC2661B VRC2661B VRC2061B VRC2061B VRC1061B VRC1001B Limitations for new remote machines that have the mixing valve mounted in the condenser. Maximum Rise is 35 feet. Maximum...

 Open the catalog to page 11
ICEU150, ICEU220 and ICEU300 Undercounter Series*-12

ICE Series Electrical and Plumbing Requirements Electrical and Plumbing Requirements: ICEU150, 220, 225 and 226 31.00 Note: The ICEU150, 220, 225 and 226 do not have a splash curtain. These models utilize a thermostatic bin control in place of a mechanical bin switch. ON-OFF-WASH Switch is located in the control box. Remove the grill screws to access the control box. Page 6

 Open the catalog to page 12

All Ice-O-Matic catalogs and technical brochures

  1. CIM0530/0535

    2  Pages

  2. CIM0330/0335

    2  Pages

  3. CIM2046/2047

    2  Pages

  4. GEM0450

    2  Pages

  5. GEM0650/0655

    2  Pages

  6. MFI1256/1255

    2  Pages

  7. GEM2006

    2  Pages

  8. Ec03 IceTM

    2  Pages

  9. ICEU86

    2  Pages

  10. GEM0956/0955

    2  Pages

  11. ICEU106

    2  Pages

  12. ICE1806/1807

    2  Pages

  13. ICEU46

    2  Pages

  14. ICEU36

    2  Pages

  15. ICEU56

    2  Pages

  16. ICEU186

    2  Pages

  17. ICEF155

    2  Pages

  18. GEM1306

    2  Pages

  19. Full Line

    20  Pages

  20. ICE0726

    2  Pages

  21. MFI0800/0805

    2  Pages

  22. IOD200

    2  Pages

  23. IOD250

    2  Pages

  24. IOD150

    2  Pages

  25. WATER FILTERS

    2  Pages

  26. Storage Bins

    2  Pages

  27. GEMU090 Series

    16  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.