BK202

BK202

BK202

Product catalog summary

Fitting Instructions Overview

This document provides step-by-step instructions for fitting and cartridge replacement for various Bark models including DJ & MH RU BK 200-202, DJ RU BK 220, RU 201-203-223, and DJ RU BK 250-350.

Section 1: Fitting Specifications

  • Applicable pipe diameters: Maximum Ø37mm (1.46 inches), Minimum Ø35mm (1.38 inches).

Section 2: Flow Rate Adjustment

  • To reduce flow rate: tighten the fitting.
  • To increase flow rate: loosen the fitting.

Section 3: Cartridge Removal and Replacement

  • Cartridge removal steps are provided for DJ & MH RU BK 200-202, DJ RU BK 220, and RU 201-203-223 models.
  • Minimum and maximum insertion depths for cartridge removal are specified as 130 mm (5.12 inches) minimum and 170 mm (6.69 inches) maximum.
  • Specific cartridge replacement instructions are given for DJ RU BK 250-350 models.

Critical Parameters and Recommendations

  • Ensure pipe diameter compatibility within specified range for proper fitting.
  • Adjust flow rate carefully by tightening or loosening to achieve desired performance.
  • Follow specified insertion depths during cartridge removal to avoid damage.
  • Refer to model-specific instructions for cartridge replacement procedures.
See more

Catalog excerpts

BK202-1

ISTRUZIONI DI MONTAGGIO FITTING INSTRUCTIONS INSTRUCTIONS DE MONTAGE ‘ _ ' d . >«N | J Lujj I

 Open the catalog to page 1
BK202-4

MH200-202 Step 03 Avvitare per diminuire la portata. Tighten to reduce the flow rate. Visser pour réduire le débit. Step 04 Svitare per aumentare la portata. Loosen to increase the flow rate. Dévisser pour augmenter le d

 Open the catalog to page 4
BK202-5

DJ & MH RU BK 200-202 + DJ RU BK 220 + RU 201-203-223 Smontaggio cartuccia Cartridge removal Démontage de la cartouche

 Open the catalog to page 5
BK202-7

Step 03 DJ RU BK 250 - 350 Sostituzione cartuccia / Cartridge replacement Remplacement de la cartouche / j~J I jj-Ju

 Open the catalog to page 7
BK202-8

Pressure & Temperature Requirements ■vJ- Hot and cold water inlet pressures should be equal. Inlet pressure range: 150-1000 kPa New Regulation: -500 kPa maximum operating pressure at any outlet within a building. (Ref. AS/NZS 3500.1-2003, Clause 3.3.4) ■Jr Maximum hot water temperature: 80°C. Italian design culture iB Rubinetterie S.p.A. Via dei Pianotti 3/5 25068 SAREZZO (BS) Italy Iscr. Reg. Impr. BS 01785230986 R.E.A. BS 352087 P.IVAIT01785230986 Capitale Sociale € 420.000,00 i.v. phone +39 030 802101 fax +39 030 803097 [email protected] www.ibrubinetterie.it

 Open the catalog to page 8

All IB RUBINETTERIE catalogs and technical brochures

  1. TAAAC 206

    10  Pages

  2. ID220

    8  Pages

  3. SB396

    4  Pages

  4. MG206

    12  Pages

  5. BK250

    8  Pages

  6. BK220

    8  Pages

  7. A9R2276

    4  Pages

  8. BK200

    8  Pages

Archived catalogs

  1. Under :: 2.0

    1  Page

  2. iB - Tech

    50  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.