HVAC Adiabatic Systems Brochure
2Pages

{{requestButtons}}

Catalog excerpts

HVAC Adiabatic Systems Brochure - 1

The hygiene concept deliberately does away with biocide and chemical disinfectants. Only demineralized water* without additives gets into the air you breathe. Power rating Current connection Voltage connection Control signal * Dimensions Vortex modules The systems contain no porous or water storing components. Standing water is effectively eliminated and when stopped, the system is automatically emptied and checked at regular cycles in compliance with VDI 6022. In the HPS and LPS models only inert materials come into contact with the humidification water and thanks to their material properties ensure hygienically safe and flawless humidification - a basic prerequisite in air conditioning. Absorbtion distance (optimum) Overall installation length, min. Flow rate Conserving resources HygroMatik’s adiabatic humidification systems provide high humidification performance and low energy consumption. Thanks to their high efficiency and exact controllability, the systems provide a particularly efficient use of the demineralized water* employed. The HPS and LPS comply with German standards VDI 6022, 3803 and DIN 1946, the equivalent Austrian and Swiss standards and European Standard DIN EN 13779. HygroMatik systems means fast amortization and long service life by using high quality components. Pressure drop in duct Humidification with demineralized water* prevents scaling and guarantees low maintenance requirements. Power rating Current connection Voltage connection Control signal * Dimensions Vortex modules A recognized, independent testing laboratory has examined and confirmed conformity with the Directives and the recognized state of the art technology (VDE Test Report No. 8023003980-0001/85569 for HPS, and VDE Test Report No. 802300–3980–002/141937 for LPS). The HPS and LPS are CE-certified and hold the hygiene conformity certificate for air conditioning and hospitals. Absorption distance (optimum) Overall installation length, min. Flow rate Pressure drop in duct Made only with inert materials * Other control signals on request Subject to technical amendments without notice Control system optimized for hygiene Simple modular assembly as per VDI 6022 requirements Adjustment of flushing and idling parameters during commissioning Installation and commissioning by qualified staff All components are easy to clean Maintenance according to schedule - annually or every 2500 h Fast and long-term availability of spare parts Extensive service partner network Technical Hotline hygienic operation * Residual conductivity 5-20 µS/cm Service Installatio Humidifying and Cooling Adiabatic High and L

Open the catalog to page 1
HVAC Adiabatic Systems Brochure - 2

high pressure nozzle system The adiabatic HPS and LPS, high and low pressure nozzle systems by HygroMatik, humidify the air in air conditioning and ventilation systems with demineralized water and offer very high humidification with particularly low energy consumption and high control accuracy. low pressure nozzle system High-precision, stainless steel nozzles produce a very fine mist which is rapidly absorbed into the air in the humidification chamber. With their varying spray angles and the production of optimal droplet sizes, they ensure almost completely dry walls in the humidification...

Open the catalog to page 2

All HygroMatik catalogs and technical brochures

  1. MultiLance

    1 Pages

  2. Hot Yoga

    1 Pages

  3. LPS Brochure

    2 Pages

  4. VN Brochure

    4 Pages

  5. HDS Brochure

    2 Pages

  6. HyLine

    2 Pages

  7. VortexSteam

    2 Pages

  8. HygroMatik

    2 Pages