Reliable Ground Improvement for Weak Soils
Introduction
The document discusses the Ringtrac® system, a reliable ground improvement solution for soils with very low bearing capacity. It highlights the system's ability to provide high stability during and after construction, accommodate high loads, minimize settlement, and allow rapid construction without risk of bearing failure.
Challenges and Goals
Constructing embankment foundations on weak soils presents challenges such as large-scale settlement, lateral deformation, and risks of bearing and slope failure. The document compares various methods and solutions, emphasizing the suitability of Ringtrac-encased columns for soft strata with low undrained shear strength (su).
Special Performance Features
Ringtrac columns are geotextile-encased columns that improve load-bearing capacity. They are suitable for extremely soft soils and offer benefits such as filtration stability, high ductility, and cost-effectiveness. The columns act as megadrains, speeding up the consolidation process.
System Design and Installation
The system uses a triangular column grid for maximum efficiency. It allows for horizontal reinforcement to prevent mixing of subsoil and embankment material. The document outlines three installation methods: displacement, vibro displacement, and replacement, each with specific benefits.
Applications
Ringtrac columns are used in various applications, including road and rail embankments, land reclamation, dams, and improvements to liquefaction-prone soils. The document provides examples of successful projects in Germany, Brazil, Turkey, and Poland.
HUESKER Services
HUESKER offers comprehensive services, including technical consulting, design calculations, project-specific placement plans, and on-site instruction. They provide digital resources and training to support the implementation of their solutions.
Conclusion
The Ringtrac system is presented as a cost-effective, reliable, and adaptable solution for ground improvement in weak soils, with a focus on rapid construction and minimal environmental impact.
See more

Catalog excerpts

Ringtrac®-1

Ringtrac® Reliable Ground Improvement for Weak Soils

 Open the catalog to page 1
Ringtrac®-2

Reliable Ground Improvement Particularly for Soils with very low Bearing Capacity Challenges and goals Comparison of methods and solutions The design of reliable embankment foundations on weak soils pose a major challenge. In addition to large-scale settlement and lateral deformation, potential risks include bearing and slope failure, or even the squeezing-out of soil from beneath the embankment base. Selection of the most suitable foundation method is dictated by the soil conditions, loads and requirements placed on the structure. Key parameters for describing the soil conditions include the...

 Open the catalog to page 2
Ringtrac®-3

• Suitable for soft strata with su < 15 kN/m² • Filtration stability between adjoining ground and column fill • No column failure due to bulging/shear/buckling action • High system redundancy • High ductility • Megadrain • Cost-effective thanks to use of locally sourced fill materials The Geotextile-Encased Column Column Integrity for Load Transmission in Extra-Soft Soils Innovative foundation The Ringtrac foundation system takes the form of a regular arrangement of columns comprising non-cohesive material placed inside a geosynthetic casing. The geotextile-encased column represents an improvement...

 Open the catalog to page 3
Ringtrac®-4

The Geotextile-Encased Column System How the system works The columns ensure that the structural loads are transmitted through the weak subsoil to a stratum with adequate bearing capacity. The system's high ductility enables it to accommodate fluctuations in actions and soil properties through load redistribution. Applications • Standard road and rail embankments • Land reclamation • Dams and dikes • Road and rail access for mining • Improvements to liquefaction-prone soils The following design parameters can be used to adapt the system to virtually any construction application • Circumferential...

 Open the catalog to page 4
Ringtrac®-5

Displacement method Most common installation method whereby circumferential tensile forces are activated under imposed loads (embankment etc.). • Steel tube with closing base flaps • Tube sunk to bearing stratum • Geosynthetic casing inserted into steel tube • Casing filled with granular and non-cohesive material, e.g. sand, gravel, crushed stone and recycled material • Steel tube withdrawn from ground under vibration • Circumferential tensile forces activated by column expansion under imposed loads Replacement method Low-impact installation method with no dynamic effects on surrounding area....

 Open the catalog to page 5
Ringtrac®-6

• Suitable for extremely soft soils • 50-75 % reduction in creep settlement • Dynamic loads (e.g. from passing trains) accommodated without damage • Adjacent buildings unaffected by settlement • Neighbouring structures shielded from horizontal pressure • Full loadability immediately after completion • Adaptability to local conditions and loads • Permeability of weak subsoil maintained • Suitable in conjunction with confined groundwater thanks to base seal HUESKER RingtracS software Reliable design to meet any challenge RingtracS is a design software application purpose-developed by HUESKER's...

 Open the catalog to page 6
Ringtrac®-7

Application Examples Mühlenberger Loch Turkey, 2012 – 2014, underwater foundation for 20 m high traffic embankment in earthquake region. Installation at up to 7 m water depths. Brazil, 2004 – 2010, foundation system for thick, soft, waterlogged soil stratum with low bearing capacity by Sepetiba Bay. The approx. 900 ha site was used to build a new steel mill. Germany, 2001 – 2003, extension to DASA Airbus plant at Hamburg-Finkenwerder, made possible by reclamation of 140 ha of land directly by River Elbe. The overall foundation system incorporated 60,000 geotextile-encased columns for a 2.4 km...

 Open the catalog to page 7
Ringtrac®-8

On-The-Spot • On-site instruction Where required, our application technicians can offer installation assistance related to the specifics of product installation. • Installation aids We can offer you practical installation aids to facilitate the application of our products. • Training Product and application-specific instruction. HUESKER Services HUESKER services begin with providing the customer with initial advice and end with supporting the realisation of the project on site. What we provide are safe, customised, ecologically sound and economically viable project solutions. Engineering Services...

 Open the catalog to page 8
Ringtrac®-9

Ringtrac® and Stabilenka® are registered trademarks of HUESKER Synthetic GmbH. HUESKER Synthetic is certified to ISO 9001, ISO 14001 and ISO 50001. □ HUESKERIdeen. Ingenieure. Innovationen. 09/17 H Copyright by HUESKER Synthetic GmbH, Gescher

 Open the catalog to page 9
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.