1. Catalogs
  2. Honeywell
  3. F50F and F300E Electronic Air Cleaners

F50F and F300E Electronic Air Cleaners

F50F and F300E Electronic Air Cleaners

F50F and F300E Electronic Air Cleaners

Product catalog summary
Operating Your Electronic Air Cleaner
To ensure maximum efficiency, it is recommended to run the air cleaner continuously by setting the thermostat fan switch to 'On'. The device consumes minimal power, similar to a 40-watt light bulb, and continuous operation helps maintain even room temperature and air cleanliness.
Maximizing Performance
For optimal performance, keep the prefilter(s) and cell(s) clean. A dirty prefilter can reduce airflow and efficiency. Implement a wash reminder schedule for regular maintenance and replace the postfilter every six months. If using a humidifier, additional filters may be necessary to prevent mineral buildup.
Cleaning Guidelines
Regular cleaning is crucial for maintaining performance. Prefilters should be vacuumed or rinsed every six months. Cells can be wiped with a damp cloth or washed thoroughly. Postfilters should be replaced rather than washed.
Functionality of Electronic Air Cleaning
The air cleaner removes particles smaller than ten microns, which can cause allergies and stain surfaces. It uses ionizer wires to charge particles, which are then collected on oppositely charged plates, reducing indoor air pollution and protecting HVAC components.
Ozone Considerations
The air cleaner generates a small amount of ozone, within safe limits. Ozone levels can be reduced by installing an activated carbon filter or adjusting the power supply, though this may slightly reduce cleaning efficiency.
Introduction to White Dust
White dust consists of particles that settle from the air before reaching the return air duct. To prevent accumulation, run the fan constantly, ensure return registers are not blocked, and keep discharge ducts clean. Humidifiers using undistilled water may contribute to white dust.
Troubleshooting Guide
For issues, ensure the blower is running, access doors are closed, and the On-Off switch is correctly positioned. Frequent arcing may require turning off the cleaner if cells are wet, checking for broken wires, or cleaning dirty cells. Contact a dealer if the ozone smell is objectionable.
Honeywell 10 Year UltraClean Coil Guarantee™
Honeywell offers a guarantee for cleaning indoor coils if maintained properly, covering 75% of cleaning costs (up to $150) with a Honeywell Coil Irradiation Ultraviolet Air Treatment System, or 50% (up to $100) without it. Proper maintenance includes keeping the power switch on and periodic cleaning.
Warranty Information
Honeywell provides a five-year warranty against defects in workmanship or materials under normal use, covering repair or replacement but excluding removal or reinstallation costs. Damages caused by consumer possession are not covered. Registration can be done online or via mail.
Product Registration
Customers are encouraged to register their products online or by mail, providing details such as purchase date, price, and personal information to assist with warranty claims and customer support.
See more

Catalog excerpts

F50F and F300E Electronic Air Cleaners-1

F50F and F300E Electronic Air Cleaners OWNER’S GUIDE

 Open the catalog to page 1
F50F and F300E Electronic Air Cleaners-2

OPERATING YOUR ELECTRONIC AIR CLEANER Turn the On-Off switch on the power box to On. NOTE: Set the switch to 1 for On and set the switch to O for Off. The air cleaner now operates whenever your furnace/air conditioning system fan operates. For maximum air cleaning benefit and cleaner air conditioner coils, leave the air cleaner switch turned on at all times and the thermostat fan switch set to On. Of course, continuous fan operation adds to your electric bill each month. Check your equipment for the amount of electricity needed to run your System fan. When the fan and air cleaner come on, the...

 Open the catalog to page 2
F50F and F300E Electronic Air Cleaners-3

CLEANING PREFILTER(S), CELL(S) AND POSTFILTER(S) A CAUTION Sharp edges. Can cause personal injury. Carefully handle cell(s) or wear protective gloves to avoid cuts from sharp metal edges. Setting a regular cleaning schedule To ensure optimum performance from the air cleaner, the prefilter(s) and cell(s) must be cleaned regularly— twice a year with normal use or more frequently with heavy use. Use the wash reminder schedule below to help establish and maintain a regular cleaning schedule. Mount the wash reminder schedule in a convenient location. ELECTRONIC A IR CLEANER WASH RE MINDER SCHEDULE...

 Open the catalog to page 3
F50F and F300E Electronic Air Cleaners-4

A CAUTION Burn Hazard. Can cause personal injury. Allow cell(s) to cool completely in dishwasher and at tend of wash cycle or wear protective gloves. Washing the cell(s) in your automatic dishwasher Hot water can accumulate in the tubes supporting the collector plates.Tip the cell(s) so these tubes can drain. IMPORTANT • Checkyour dishwasher Owner’s manual. Some manufacturers do not recommend washing electronic cell(s) in their dishwashers. • If the dishwasher has upper and lower arms, position the cell(s) carefully to allow good water circulation. • Be careful to avoid damaging the cell(s) when...

 Open the catalog to page 4
F50F and F300E Electronic Air Cleaners-5

Turn on the air cleaner. If the cell(s) and prefilter(s) are wet, the neon light may not come on and you may hear arcing. If the arcing is annoying, simply turn the air cleaner off for two to three hours or until the cell(s) are dry. How the electronic air cleaner works First, large particles (lint, hair) are caught by the prefilter(s). Then, as the dirty air passes through the intense high voltage electric field surrounding the ionizer wires, all particles, even the smallest particles down to 0.3 micron are given an electric charge.The air then passes into the collector where the alternate parallel...

 Open the catalog to page 5
F50F and F300E Electronic Air Cleaners-6

Send to: Honeywell 10 Year UltraClean Coil Guarantee Customer Care, MN10-1461 1885 Douglas Drive North Golden Valley, MN 55422 Ozone and the electronic air cleaner Electronic air cleaners generate a very small amount of ozone, about 0.005 to 0.010 parts per million (ppm). The amount is highest when the air cleaner is new. The average person can detect the odor of ozone in concentrations as low as 0.003 to 0.010 ppm. The U.S. Food and Drug Administration, and Health and Welfare Canada recommend that indoor ozone concentration should not exceed 0.050 ppm. As a comparison, the outdoor ozone level...

 Open the catalog to page 6
F50F and F300E Electronic Air Cleaners-7

LIMITED FIVE-YEAR WARRANTY EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you. THE WARRANTIES SET FORTH HEREIN ARE EXCLUSIVE, AND HONEYWELL EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES, WHETHER WRITTEN, ORAL, IMPLIED OR STATUTORY, INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY, WORKMANSHIP, OR FITNESS FOR A PARTICULAR PURPOSE. Honeywell warrants this product to be free from defects in the workmanship or materials, under normal use and service,...

 Open the catalog to page 7
F50F and F300E Electronic Air Cleaners-8

Product Registration (Register online @ www.honeywell.com/yourhome) 1. Mr____ Mrs____ Ms____ Miss____ First Name:______________Initial:___ Last Name:________________________ Address (Number and Street):____________________________ Apt:__________ Zip or Postal Code__________________________________________________ City:___________________________ State/Province:______________________ email Address:__________________________________________________ Phone Number:_______________________________________________ Date of Purchase (month/day/year) ex: January/18/98: Purchase Price: $_____________________________________(excluding...

 Open the catalog to page 8

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.