HM 80 - 1

UNIVERSAL MIXING VALVE CONTROLLER PRODUCT DATA GENERAL The wireless Universal Mixing valve Controller is used for heating/cooling zoning control. The HM 80 controls the mixing valve depending on the room temperature and room setpoint by using fuzzy control logic to keep the room temperature precisely constant. It can be done with and without the flow sensor T7414C1012 (optional) The pump can be controlled directly with the HM 80 relay output 230V~. SPECIFICATIONS ELECTRICAL Electrical voltage supply : 230V ~ , 50Hz, max. 6A Pump relay Mixing valve relay free relay contact free relay contact FEATURES • Direct control of mixing valve actuators for individual room temperature control • The HM 80 is communicating with the Chronotherm CM67RFMV, (CM67z) to keep the room temperature constant, time program, holiday function Receiver class • Manual or automatic control • Simple binding operation to reduce installation time and costs RF communication range : 30m in a residential building environment RF communication Technology • Pump control, after running time adjustable 0..99 min. • External Flow Sensor connectable NTC 20KΩ, 25°C not linear (type T7414C1012) : short, high rate transmission to minimize air time and avoid collisions • Maintenance run for pump and mixing valve Storage temperature • Boiler feedback heat on demand with CM67RFMV,CM67z Operating temperature Dimensions (HxWxD) • Heating / Cooling operation Cover : PC-FR VO certificated connectable Compatible products Approv

Open the catalog to page 1
HM 80 - 3

Application EXAMPLES Application A Mixing Valve Application for UFH without boiler feedback CM67RFMV with parameter settings Flow temperature sensor T7414C1012 (optional) Pump after running time 0…99 min Actuator running time 0…240 s Min flow temperature setpoint 0…50°C Max flow temperature setpoint 0…99°C HM80 Pump M Mixing Valve The HM80 controls the mixing valve depending on the room temperature setpoint and communicates with the CM67RFMV. In addition the controller has a relay output for pump control and connection for the flow sensor. Without using the flow sensor the mixing valve...

Open the catalog to page 3
HM 80 - 4

Application C Mixing Valve Application for UFH and Radiator Control HR80 Valve Application for UFH and Radiator Control HR80 without boiler feedback without boiler feedback CM67z Flow temperature sensor T7414C1012 sensor T7414C1012 (optional) (optional) Default parameters are: Default parameters are: Pump after running time 15 min Pump after running time 15 min Actuator running time 150 s Actuator running time 150 s Min flow temperature setpoint 15°C Min flow temperature setpoint 15°C Max flow temperature setpoint 55°C Max flow temperature setpoint 55°C CM67z without programmi programmi...

Open the catalog to page 4
HM 80 - 5

Mixing Valve Applications for UFH and Radiator Control HR80 with boiler feedback Flow temperature sensor T7414C1012 sensor T7414C1012 (optional) (optional) Pump after running time 15 min Actuator running time 150 s Actuator running time 150 s Min flow temperature setpoint 15°C 55°C Max flow temperature setpoint 55°C CM67z without programming Parameters , only default parameters are used parameters are used Mixing Valve Boiler feedback Boiler feedback HC60NG HC60NG R6660D R6660D Boiler Ademco 1 GmbH Hardhofweg 40 74821 Mosbach Phone: +49 1801 466 388 info.de@resideo.com homecomfort.resideo...

Open the catalog to page 5