Catalog excerpts
PERFORATED TAPE TWO THICKNESSES Simple and effective system to achieve floor bracing. It is available in thicknesses of 1,5 and 3,0 mm. CLIPSET Simply and effortlessly secures the ends of the tape in many applications of floor and roof bracing. SPECIAL STEEL Made with S350 GD high strength steel. The 1,5 mm thick version offers extreme resistance to tensile forces with minimal thickness. CHARACTERISTICS FOCUS tension fastening MATERIAL Carbon steel with bright zinc plated perforated tape. FIELD OF USE Timber-to-timber joints • solid timber and glulam • CLT, LVL • timber based panels 386 | LBB | ANGLE BRACKETS, HANGERS AND PERFORATED PLA
Open the catalog to page 1BRACINGS This system is ideal for creating safe, quick and effective bracing. The use of high quality steel ensures that the tapes reduced thickness does not compromise the tensile strength. STABILITY The CLIPSET can be added to the ends of the 60 mm version to achieve secure and safe fastening on any structure. ANGLE BRACKETS, HANGERS AND PERFORATED PLATES | LBB | 387
Open the catalog to page 2Terminal plate EXTERNAL LOADS LBB 1,5 mm: carbon steel S350GD+Z275. LBB 3,0 mm: carbon steel S250GD+Z275. CLIPSE : carbon steel DX51D+Z275. To be used in service classes 1 and 2 (EN 1995-1-1). FIELD OF USE • Timber-to-timber joints ADDITIONAL PRODUCTS - FASTENING type Anker nail 388 | LBB | ANGLE BRACKETS, HANGERS AND PERFORATED PLA
Open the catalog to page 3TIMBER - MINIMUM DISTANCES Load-to-grain angle α = 0° Anker nail Lateral connector - unloaded edge CLIPSET ASSEMBLING CLIP-FIX TENSIONER 01 Insert the perforated tape Insert the perforated tape CLIP-FIX TERMINAL Use the tensioner to regulate the length of the bracing system ANGLE BRACKETS, HANGERS AND PERFORATED PLATE
Open the catalog to page 4STATIC VALUES | TIMBER-TO-TIMBER TENSILE JOINT STRENGTH OF THE SYSTEM The tensile strength of the R1,d system is the minimum between the Rax,d plate side tensile strength and the shear resistance of the connectors used for fastening ntot · Rv,d. If the connectors are placed in several consecutive rows and the load direction is parallel to the grain, the following sizing criteria must be applied. Where mi is the number of rows of connectors parallel to the grain and ni is the number of connectors arranged in the same row. TAPE -TENSILE STRENGTH CHARACTERISTIC VALUES type CONNECTORS SHEAR...
Open the catalog to page 5CALCULATION EXAMPLE | TIMBER-TO-TIMBER TENSIL JOINT WITH LBV AND LBB F1,d PROJECT DATA Strength Service class Load duration Solid timber CL24 Element 1 Element 2 Element 3 USABLE PRODUCTS perforated plate LBV401200(2) B = 40 mm s = 2 mm H = 600 mm Anker nail LBA440(1) d1 = 4,0 mm L = 40 mm perforated tape LBB40 B = 40 mm s = 1,5 mm Anker nail LBA440(1) d1 = 4,0 mm L = 40 mm EVALUATION OF THE STRENGTH OF THE SYSTEM TAPE/PLATE - TENSILE STRENGTH perforated plate LBV401200(2) perforated tape LBB40 Rax,k CONNECTOR - SHEAR STRENGTH perforated plate LBV401200(2) perforated tape LBB40 PERFORATED...
Open the catalog to page 6All HOLZ TECHNIC catalogs and technical brochures
-
TITAN F
9 Pages
-
TITAN N
17 Pages
-
TITAN PLATE C
8 Pages
-
TITAN PLATE T
4 Pages
-
UV-T
9 Pages
-
WHT PLATE T
4 Pages
-
XEPOX
14 Pages
-
FACADE BAND UV
2 Pages
-
WINDOW BAND
2 Pages
-
PROTECT
2 Pages
-
LEVEL BAND
1 Pages
-
BUTYL BAND
1 Pages
-
ALU BAND
1 Pages
-
AIR GLUE
2 Pages
-
WHT PLATE C
8 Pages
-
SILENT FOAM
2 Pages
-
GROUND BAND
4 Pages
-
FILLUM
1 Pages
-
COMPRIMO
1 Pages