Technical Specifications:
The document provides technical data for Hoesch Isowand Integral® panels, including compliance with EN ISO 6946, EN 13165, and EN 14509 standards. The panels are available in standard cover widths of 1000 mm and special widths of 600 mm, 900 mm, and 1200 mm. The outer sheet thickness varies between 0.60 mm and 0.75 mm depending on product specifications.

Product Details:
The panels are made with quality flat steel S280 GD, with options for S320 GD and S350 GD, and feature a metallic coating. The insulation core is made of polyisocyanurate rigid foam (PIR) with a nominal density of 39 kg/m³. The panels have a sound protection rating of Rw = 25 dB and conform to EN 14509 standards.

Fire and Environmental Standards:
The building material classification is B-s1, d0 according to EN 13501-1. Environmental Product Declarations (EPD) and BREEAM® certification are available for panels with rigid foam insulation cores.

Installation and Guarantee:
The document recommends using vacuum lifters from Viavac and Wirth for installing large panels. A product guarantee offers over 30 years of protection for the steel cores of the cover sheets, subject to guarantee conditions.

Additional Information:
For more details on fire resistance classes and installation recommendations, the document directs readers to the website www.hoesch-bau.com.
See more

Catalog excerpts

Hoesch isowand integral® Technical Data-1

hOEsCh IsOwaND INTEgral® TEChNICal DaTa Cross section Standard cover width: 1000 mm longitudinal joint Cover width Cover width Option: Hoesch isowand integral® with FSI window system. The harmonised joint geometry of the window frame and the sandwich element avoids thermal bridges. For more information, please see our brochure (“Unique façade design Hoesch isowand integral®”) or go to our website. Screw with 16 mm washer, approved by the building authorities, as per structural require- Cover width Panel width material thickness 60* 80* 600** Hoesch isowand integral® Thermal resistance heat transition coefficient gemäß EN ISO 6946 In accordance with EN ISO 6946 Thermal resistance heat transition coefficient gemäß with EN 13165 In accordanceEN 13165 und and mit joint influence EN 14509 withFugeneinfluss* Note: * element thickness on request ** In the case of elements with a cover width of 600 mm, the protective foil must be manually removed before installation! EN standards need to be applied in the legally valid form specific to each country. The data above shows what is technically possible. To see the range of product versions which can be delivered, please visit the website www.hoesch-bau.com or contact your competent sales partner. For colour groups II and III the outer sheet must be 0.60 mm or 0.75 mm thick depending on the exact product specification requirements. GB · Hoesch isowand integral® · 04/2016 Die einzelnen Angaben in diesem Datenblatt gelten nur dann als zugesicherte Eigenschaft, soweit sie jeweils im Einzelfall ausdrücklich als solche schriftlich bestätigt sind. Technische Änderungen vorbehalten. Special cover width: 600 mm,

 Open the catalog to page 1
Hoesch isowand integral® Technical Data-2

HOESCH BAUSYSTEME HOESCHlISOWAND INTEGRAL® TECHNICAL DATA Outer sheet Inner sheet Cover sheet profiling Micro-profiled (M) Nominal dimensions in mm, tolerances in accordance with works specifications. lengths supplied: 2 m to 20 m (lengths below 2 m on request) Packaging: Standard packaging according to works specification; special packaging on request Material: Cover sheets: Quality flat steel S280 GD (S320 GD and S350 GD on request) with metallic coating in accordance with EN 10326. Surface finish using <D various coating systems and multiple layers e.g. of the Evoshine® brand. pecial...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.