Autonomous Units Water Air - AirAir WIDE RANGE OF WATER - AIR UNITS FOR THE COMMERCIAL SECTOR Hitecsa offers the widest range of Water - Air solutions for installations in shopping centres. These buildings are usually designed with energy loop systems which supply heated water to the different premises for the shops that make up the shopping centre. INSTALLATION EXAMPLE WITH A WATER LOOP WATER AIR HE WITH PLUG FAN For greater energy efficiency 4 MODELS IN TWO DIFFERENT FORMATS PLATE HEAT EXCHANGER COAXIAL EXCHANGER • Horizontal format • Horizontal format • Vertical format • Vertical format

Open the catalog to page 2
Autonomous Units Water-Air 2018 General Catalogue - 3

Autonomous Units Water - Air ADVANTAGES OF THE HITECSA WATER-AIR HE RANGE • Maximum comfort for shopping centres, premises, offices, dwellings... • Discreet solutions, designed for installation inside the premises to be air-conditioned. 2018 General Catalogue HITECSA COOL AIR

Open the catalog to page 3
Autonomous Units Water-Air 2018 General Catalogue - 4

Autonomous Units Water Air - AirAir WCHBZ HE Heat pump WCHZ HE Cooling only COMPACT CONFIGURATION Horizontal | Coaxial Robust and adaptable solutions for installations with an energy loop Autonomous compact horizontal units equipped with a water-cooled coaxial condenser, suitable for connection to a network of distribution ducts. ________________________________________ MAIN FEATURES • • • • • Maximum cooling capacities ranging from 6.4 to 25.1 kW Coaxial condenser Airflows up to 4,600 m3/h Heating capacities ranging from 6.0 to 16.5 kW Plug fan as standard AVAILABLE VERSIONS Robustness...

Open the catalog to page 4
Autonomous Units Water-Air 2018 General Catalogue - 5

WCHBZ HE SERIES Heat pump Autonomous Units Water - Air Standard Optional WCHZ HE SERIES Cooling only MODEL (1) Dry air temperature 27 0C. Indoor wet air temperature 19 0C. Water inlet temperature 30 0C, water outlet 35 0C. (2) Dry air temperature 20 0C. Indoor wet air temperature 14 0C. Water inlet temperature 16 0C. (3) Calculated in accordance with standard EN 14511:2013 (4) Air return 27/19°C. Water inlet 10°C / Water outlet 15°C. (5) Air return 20°C. Water inlet 10°C / Water outlet 15°C. (6) Static pressure with centrifugal fan (optional). Consult pressures with plug fan (standard).

Open the catalog to page 5
Autonomous Units Water-Air 2018 General Catalogue - 6

Autonomous Units 'Water - Air d= ENERGY SAVING • Option of mixing module for freecooling with two and three dampers (depending on models) • Thermal or enthalpy regulation with pPC control card and PGD control • Compressor soft-start (depending on models) • Fan soft-start (depending on models) ~ AIR QUALITY • Gravimetric filter in return G4 • Opacimetric filter in return class F6 to F9 (combinable with a G4 or Fx+Fy) NOISE LEVEL • Double thermo-acoustic insulation • Compressor acoustic insulation UNIT INSTALLATION • Water differential pressure switch • Magneto-thermal switches in the...

Open the catalog to page 6
Autonomous Units Water-Air 2018 General Catalogue - 7

Autonomous Units Water - Air Heat pump Cooling only COMPACT CONFIGURATION Vertical | Coaxial Robust and adaptable solutions for installations with an energy loop Autonomous compact vertical units equipped with a water-cooled coaxial condenser, suitable for connection to a network of distribution ducts. ________________________________________ MAIN FEATURES • Maximum cooling capacities ranging from 6 to 120 kW • Coaxial condenser • Airflows up to 21,500 m3/h • Plug fan as standard ADVANTAGES • Robustness against water impurities • Easy access to inside the unit for maintenance purposes •...

Open the catalog to page 7
Autonomous Units Water-Air 2018 General Catalogue - 8

Autonomous Units 'Water - Air POSSIBLE AIR INLET/OUTLET CONFIGURATIONS WCVBZ HE 201-351 t AVAILABLE OPTIONAL FEATURES -d= ENERGY SAVING • Option of mixing module for freecooling with two and three dampers • Thermal or enthalpy regulation with ijPC control card and PGD control • Compressor soft-start (depending on models) • Fan soft-start (depending on models) ~ AIR QUALITY • Gravimetric filter in return G4 • Opacimetric filter in return class F6 to F9 (combinable with a G4 or Fx+Fy) NOISE LEVEL • Double thermo-acoustic insulation • Compressor acoustic insulation UNIT INSTALLATION •...

Open the catalog to page 8
Autonomous Units Water-Air 2018 General Catalogue - 9

Autonomous Units Water - Air WCVZ HE SERIES Cooling only MODEL (1) Dry air temperature 27 0C. Indoor wet air temperature 19 0C. Water inlet temperature 30 0C, Water outlet 35 0C. (2) Dry air temperature 20 0C. Indoor wet air temperature 14 0C. Water inlet temperature 16 0C. (3) Calculated in accordance with standard EN 14511:2013 (4) Air return 27/19°C. Water inlet 10°C / Water outlet 15°C. (5) Air return 20°C. Water inlet 10°C / Water outlet 15°C. (6) Static pressure with centrifugal fan (optional). Consult pressures with plug fan (standard).

Open the catalog to page 9
Autonomous Units Water-Air 2018 General Catalogue - 10

Autonomous Units Water Air - AirAir WPHBA HE Heat pump HE WPHA HE Cooling only COMPACT CONFIGURATION Horizontal | Plates Robust and adaptable solutions for installations with an energy loop Autonomous horizontal units equipped with water-cooled plate condensers, suitable for connection to a network of air distribution ducts. ________________________________________ MAIN FEATURES • • • • • • • • Maximum cooling capacities ranging from 2.4 to 41 kW Plate condenser Airflows of up to 7,000 m3/h Plate heat exchanger Scroll compressors (from model 351) R-410A refrigerant Thermal insulation M1...

Open the catalog to page 10
Autonomous Units Water-Air 2018 General Catalogue - 11

Autonomous Units Water - Air Standard Optional (1) Dry air temperature 27 0C. Indoor wet air temperature 19 0C. Water inlet temperature 30 0C, water outlet 35 0C. (2) Dry air temperature 20 0C. Indoor wet air temperature 14 0C. Water inlet temperature 20 0C. (3) Calculated in accordance with standard EN 14511:2013 (4) Air return 27/19°C. Water inlet 10°C / Water outlet 15°C. (5) Air return 20°C. Water inlet 10°C / Water outlet 15°C. (6) Static pressure with centrifugal fan (optional). Consult pressures with plug fan (standard).

Open the catalog to page 11
Autonomous Units Water-Air 2018 General Catalogue - 12

Autonomous Units 'Water - Air -d= ENERGY SAVING • Compressor soft-start (depending on models) • Fan soft-start (depending on models) ~ AIR QUALITY • Gravimetric filter in return G4 • Opacimetric filter in return class F6 or F9 NOISE LEVEL • Double thermo-acoustic insulation • Compressor acoustic insulation ^ UNIT INSTALLATION • Magneto-thermal switches in the electrical panel • Power supply at 60 Hz and voltages of 230, 208, etc. • Rear air discharge • Electrovalves to shut off the water • Kit for outdoor installation (upon request) • Thermal insulation Euroclass A1 (M0) • Uprated motors •...