FOR INDUSTRIAL APPLICATIONS... The autonomous air-air HITECSA series units constitute the most complete climate-control solution on the market today. The centrifugal technology in these units allows the entire installation of the system indoors, providing superior architectural integration. The many configurations available of our air-air range (horizontal or vertical, compact or split, low silhouette, 2x1, 1x2) makes us the perfect ally for finding the climate-control solution for your premises. Given their robustness, these units are ideal for industrial applications, although they are...

Open the catalog to page 2
Autonomous Units Air - Air 2018 General Catalogue - 3

... AND FOR COMMERCIAL APPLICATIONS AIR DUCTS INSTALLATION All our indoor units of the autonomous air-air range have a continuous outdoor air intake (adjustable from 1 to 9%), that allows outside air to enter, thus guaranteeing fresh air renewal in the premises. In this way, we make our systems compatible with commercial applications (COMFORT COMPATIBLE).

Open the catalog to page 3
Autonomous Units Air - Air 2018 General Catalogue - 4

CCHBA / ECHBA CCHA / ECHA Heat pump Cooling only Heat pump Cooling only ACHBA / ACHA - Compact configuration CCHBA / ECHBA CCHA / ECHA - Split configuration Maximum flexibility for climate-control via ducts Autonomous, compact and split horizontal construction units suitable for connection to both indoor and outdoor sections of a network of air distribution ducts. ________________________________________ MAIN FEATURES • • • Maximum cooling capacities ranging from 12.4 to 33.5 kW Scroll compressor R-410A refrigerant (split version: delivered with no refrigerant load) AVAILABLE VERSIONS...

Open the catalog to page 4
Autonomous Units Air - Air 2018 General Catalogue - 5

ACHBA - ACHA SERIES Compact configuration MODEL (1) Nominal cooling conditions. Indoor dry temperature: 27°C. Indoor wet temperature: 19°C. Outdoor temperature: 35°C. (2) Nominal pumping conditions. Outdoor dry temperature: 7°C. Outdoor wet temperature: 6°C.

Open the catalog to page 5
Autonomous Units Air - Air 2018 General Catalogue - 6

ECHBA - ECHA SERIES Split configuration / Indoor unit MODEL (1) Nominal cooling conditions. Indoor dry temperature: 27°C. Indoor wet temperature: 19°C. Outdoor temperature: 35°C. (2) Nominal pumping conditions. Outdoor dry temperature: 7°C. Outdoor wet temperature: 6°C. (3) Only units which include, as standard, “Flare” valves (not as optional) are charged with refrigerant; others come pre-charged with dry nitrogen. (*) For sizing of refrigerated lines depending on layout and total installation distance consult our Commercial Department.

Open the catalog to page 6
Autonomous Units Air - Air 2018 General Catalogue - 7

AVAILABLE OPTIONAL FEATURES -d= ENERGY SAVING • Option of mixing module for freecooling with two and three dampers • Thermal or enthalpy regulation with pPC control card • Condensation control by frequency converter or voltage converter • Compressor soft-start (depending on models) • Soft-start of the indoor and/or outdoor fan (depending on models) ~ AIR QUALITY • Gravimetric filter in return G4 • Opacimetric filter in return class F6 to F9 (combinable with a G4 or Fx+Fy) NOISE LEVEL • Double thermo-acoustic insulation • Compressor acoustic insulation UNIT INSTALLATION • Magneto-thermal...

Open the catalog to page 7
Autonomous Units Air - Air 2018 General Catalogue - 8

CCVBA / ECVBA CCVA / ECVA Heat pump Cooling only Heat pump Cooling only ACVBA / ACVA - Compact configuration CCVBA / ECVBA CCVA / ECVA - Split configuration Maximum flexibility for climate-control via ducts Autonomous, compact and split vertical construction units suitable for connection to both indoor and outdoor sections of a network of air distribution ducts. ________________________________________ MAIN FEATURES • • • • Maximum cooling capacities ranging from 12.5 to 114.3 kW Scroll compressor R-410A refrigerant (split version: delivered with no refrigerant load) 2 independent cooling...

Open the catalog to page 8
Autonomous Units Air - Air 2018 General Catalogue - 9

Standard Optional POSSIBLE AIR INLET/OUTLET CONFIGURATIONSECVA/CCVA - ECVBA/CCVBA ECVA-ECVBA 401 - 3502 CCVA-CCVBA 401 - 3002 CCVA-CCVBA 3502 ACVBA - ACVA SERIES Compact configuration MODEL (1) Nominal cooling conditions. Indoor dry temperature: 27°C. Indoor wet temperature: 19°C. Outdoor temperature: 35°C. (2) Nominal pumping conditions. Outdoor dry temperature: 7°C. Outdoor wet temperature: 6°C. 2018 General Catalogue HITE OS A COOL AIR

Open the catalog to page 9
Autonomous Units Air - Air 2018 General Catalogue - 10

(1) Nominal cooling conditions. Indoor dry temperature: 27°C. Indoor wet temperature: 19°C. Outdoor temperature: 35°C. (2) Nominal pumping conditions. Outdoor dry temperature: 7°C. Outdoor wet temperature: 6°C. (3) Only units which include, as standard, “Flare” valves (not as optional) are charged with refrigerant; others come pre-charged with dry nitrogen. (*) For sizing of refrigerated lines depending on layout and total installation distance consult our Commercial Department.

Open the catalog to page 10
Autonomous Units Air - Air 2018 General Catalogue - 11

(1) Nominal cooling conditions. Indoor dry temperature: 27°C. Indoor wet temperature: 19°C. Outdoor temperature: 35°C. (2) Nominal pumping conditions. Outdoor dry temperature: 7°C. Outdoor wet temperature: 6°C. (*) For sizing of refrigerated lines depending on layout and total installation distance consult our Commercial Department.

Open the catalog to page 11
Autonomous Units Air - Air 2018 General Catalogue - 12

AVAILABLE OPTIONAL FEATURES -d= ENERGY SAVING • Option of mixing module for freecooling with two and three dampers • Thermal or enthalpy regulation with pPC control card and PGD control • Compressor soft-start (depending on models) • Soft-start of the indoor and/or outdoor fan (depending on models) • Condensation control by frequency converter or voltage converter • EC radial indoor fan (depending on models) ~ AIR QUALITY • Gravimetric filter in return G4 • Opacimetric filter in return class F6 to F9 (combinable with a G4 or Fx+Fy) ^ NOISE LEVEL • Double thermo-acoustic insulation •...

Open the catalog to page 12
Autonomous Units Air - Air 2018 General Catalogue - 13

Heat pump Cooling only Low-silhouette split configuration Maximum flexibility for climate-control via ducts Sets comprising a centrifugal condenser unit (outdoor unit) and a low-silhouette direct expansion fan-coil evaporator unit (indoor unit). ________________________________________ MAIN FEATURES • Maximum cooling capacities ranging from 14.5 to 19.3 kW • indoor 3-speed fan • R-410A refrigerant (split version: delivered with no refrigerant load) AVAILABLE VERSIONS • Heat pump • Cooling only ADVANTAGES • With continuous outdoor air intake to renew the air (Comfort Compatible) • The...