INDUSTRIAL DEHUMIDIFICATION REHEATING ONLY TYPE REHEATING AND COOLING TYPE Protect your environment, - where value is born. – Johnson Controӏs - Hitachi Air Conditioning ADDRESS New Pier Takeshiba South Tower 1-16-1, Kaigan Minato-ku, Tokyo 105-0022, JAPAN Tel: +81-3-6721-5567 www.jci-hitachi.com HITACHI. CERTIFIED QUALITY The specifications of this catalog may change without prior notice to allow Hitachi Cooling & Heating to incorporate the latest innovations for its customers. The information contained in this catalog is merely informative. Hitachi Cooling & Heating declines any responsibility in the broadest sense, for damage, direct or indirect, arising from the use and / or interpretation of the recommendations in this catalog. Find the products Hitachi Cooling & Heating with the best service and conditions at your Hitachi Distributor.
Open the catalog to page 138 Optional parts and modifications
Open the catalog to page 2OVERVIEW Hitachi's commercial/industrial dehumidifiers are valuable in various fields for the purpose of dehumidification and drying. Places where humidity tends to be high due to the presence of water and steam - Indoor pools and fitness clubs - Dehumidification and drying of bathing areas in public bathrooms and inns Dehumidification, drying, and storing : - Drying and storing of fresh and processed food - Drying of food processing plants after cleaning with water - Dehumidification of precision machinery rooms and photoengraving rooms - Dehumidification of storage rooms in libraries and museums...
Open the catalog to page 3Reheating only type HITACHI Small floor type (inverter-equipped) Floor type (inverter-equipped) Small floor type (inverter-equipped) Model Floor type (inverter-equipped) RK-NP2LVX (with plenum chamber*) RK-NP4LVX (with plenum chamber*) RK-NP8LVX (with plenum chamber*) RK-NP2LTVX RK-NP4LTVX RK-NP8LTVX Reheating and cooling type Floor type (inverter-equipped) Note * Plenum chamber for direct air blow into the room is optional. 1. Dehumidification Capacity shows the value when Dehumidifier runs at rating and maximum frequency. 2. This is the capacity in reheat mode.The capacity in cooling mode is...
Open the catalog to page 4(inverter-equipped) < Reheating only type > ENHANCED CONTROL FEATURES Small floor type with small footprint. Enhanced control features by optional multi-function wired controller. The optional multi-function wired controller supports various functions. * For the following functions, an optional multi-function wired controller is required. * If the optional caster wagon is used, mount the controller on the side of the wagon. Multiple unit control function Up to 10 dehumidifiers (small floor type) can be controlled at the same time. SMALL FLOOR TYPE WITH SMALL FOOTPRINT In addition to its small...
Open the catalog to page 5(inverter-equipped) < Reheating only type > REDUCED ENERGY CONSUMPTION HITACHI Inverter control allows the unit to be used under a wide range of dehumidification load conditions as well as reducing energy consumption. It also makes it possible to reach the set humidity level within a shorter time and to respond to a greater fluctuation of dehumidification load. Depending on the fluctuation of the dehumidification load, the compressor speed is controlled by the inverter to adjust the dehumidification capacity. Compared to the constant speed type, power consumption is reduced as the unit runs more...
Open the catalog to page 6(inverter-equipped) < Reheating and cooling type > Cooling Operation RK-NP2LTVX RK-NP8LTVX HITACHI Inverter control allows the unit to be used under a wide range of dehumidification load conditions as well as reducing energy consumption. As it is a reheating and cooling type, it can prevent temperature increases in the room. Note:*5. Cooling Capacity indiates the values for the operation under the conditions:Air inlet temperature 25°C and Air inlet humidity 80%(Outside Air inlet temperature 30°C) RK-NP2LTVX RK-NP2LTVX*1 (Outdoor unit) (Outdoor unit) *1. Plenum chamber is optional. Extensive product...
Open the catalog to page 7Floor type (inverter-equipped) & Small floor type (inverter-equipped) WIDE SELECTION OF OPTIONAL PARTS A wide selection of optional parts is supported, such as a filter box for the front suction, duct set for the rear suction, and high efficiency filter. (For details, refer to P38~P45.) The system performs demand control by detecting the operating current of the compressor. This feature helps suppress the maximum power by cutting the power consumption which exceeds the set power range. * Small floor type require the optional multi-function wired controller. EASIER INSTALLATION AND IMPROVED SERVICEABILITY...
Open the catalog to page 8Floor type (inverter-equipped) & Small floor type (inverter-equipped) Useful power saving features * The following three control functions cannot be enabled simultaneously. It takes a long time to reach the set humidity/temperature (reheating andcooling type). MULTI-FUNCTION OF CONTROL PANEL The control panel supports the wired controller (PC-RKF). You can configure various features by simple operation. * The small floor type requires the optional multi-function wired controller. Powerful dehumidification (quick dehumidification) Pressing the Powerful dehumidification button *1 makes the compressor...
Open the catalog to page 9COMMON – FEATURES STANDARD ANTICORROSIVE COATING (INDOOR UNIT) Floor type (inverter-equipped) & Small floor type (inverter-equipped) MULTIPLE UNIT CONTROL Up to 10 dehumidifiers can be controlled at the same time from a single control panel. Following the wiring guideline below, wire the units correctly. Wiring guideӏine Remove the wiring connecting the control panels of units #1 through #9 and the terminal block (TB2). (Example for floor type) Heat exchanger (anticorrosive coating) (Example for small floor type) *Clear acrylic resin coating Generally, the hairpin tubes on the ends of the evaporator...
Open the catalog to page 10(inverter-equipped) < Reheating only type > Dimensional drawing of dehumidifier with Caster wagon (optional) (mm) Dimensional drawing of handle for Movement (optional) Caster Wagon Model: CW08-1 RK-NP08PVX 0.6kW 0.8Equivalent horsepower Specifications (50Hz) Dimensional drawing (mm) Model Control Panel Details •-I Handle for Movement I (Optional Parts) Holes for Anchor Bolt (4xM10) Control Panel Dimensional drawing of medium efficiency Filter (optional) Model: F08-1 Dimensional drawing of caster (optional) Model: C08-1 [Caster(with Stopper)] [Caster(without Stopper)] Dimensional drawing of round...