Smart Vent
12Pages

{{requestButtons}}

Catalog excerpts

Smart Vent - 1

Smart Vent Smart Vent 200 XP Smart Vent 200 XV Smart Vent 400 XP Smart Vent 400 XV Smart Vent 600 XP Smart Vent 600 XV V [m3/h] Apartments, private houses, villas, passive houses. Residential air handling units Smart Vent with EPP casing are characteristic of the highest energy efficiency (heat recovery rate – up to 94%) and user-friendly control. Universal positioning of Smart Vent units and the lowest height enable to find a place for them even in tight spaces. Due to compact sizing Smart Vent 200XV ideally fits in a place of a kitchen cabinet, meanwhile Smart Vent 400 XV/600 XV could fit above a regular washing machine. Every Smart Vent unit is tested for airtightness in order to assure exceptional quality of assembly. All internal components (fans, actuators, heat exchanger) are produced by top European manufacturers, which guarantees a long service life. Smart control board enables controlling all components of the ventilation system. The main features: › Class A+/A efficiency*; › EC fans with high-efficiency counter-flow heat exchangers; › High quality: Class A1 airtightness; › Smart and user-friendly handling; *- depends on the unit. Top class casing: › Thermal and acoustic insulation: EPP of 20-30 mm; › Galvanized steel plate; › The external side is powder-coated – corrosion class C3. Heat exchanger: › Plastic plate heat exchanger; › Efficiency up to 91% (EU 1253/2014) / 85% (Passivhaus). Fans: › EC type; › Specific fan input (SPI) from 0.26 W/(m3/h); › Long lifetime – fans last for more than 10 years. Motorized bypass damper: › 100% summer bypass (night cooling); Integrated pre-heater (Smart Vent 200 XV/400 XV/600 XV version 1.1 only). Filters: › Low pressure drop Coarse 65%/Coarse 65% (G4/G4) filters (effective filtration of dust, pollens); › Optional supply of ePM1 70% (F7) filter for more efficient filtration (moulds, spores, microscopic allergens, fine particles, bacteria). Integrated control board2: › Control of external components: pre-heater, heater, dampers, etc.; › Connection for demand control sensors (CO2, RH, presence); › Intelligent frost protection; › Smart el.heater control 0-10V; › Extensive control options: 3 manual modes, boost, calendar, night cooling, fireplace mode and etc. 1 2 ~40000 working hours Functionality depends on the unit The Company reserves the right to modify t

Open the catalog to page 1
Smart Vent - 2

Smart Vent Air temperature sensors Extract, Supply, Outdoor. Relative humidity sensor Extract air (Smart Vent 400 XV/600 XV V 1.1) Control options Dimensions [mm] Unit Smart Vent 200 XV The Company reserves the right to modify technical data without giving a prior notice

Open the catalog to page 2
Smart Vent - 3

Smart Vent ACCESSORIES Optional accessories Unit Network Module Control panel Control panel Electrical preheater / heater Panel filters Panel filters Humidity transmitter Nano Router Shut-off damper Smart Vent legs VERSIONS Smart Vent 200X V 1.1 Energy efficiency class Control board Product name Version Heat recovery Temp.control Bypass damper Integrated pre-heater Extracted air humidity sensor Optional heating elements Duct-based pre-heater Duct-based heater * - version V1.1 with additional CO2 or RH sensors complies to A+/A. ** - only with pre-heater or heater. The Company reserves the...

Open the catalog to page 3
Smart Vent - 4

Smart Vent XP Smart Vent 200 XP 218 Ordering code Electrical data Fans Electrical preheater integrated Electrical heater Max.power consumption Power connection Control board MiniMCB basic Ecodesign data Time control Local demand control Energy efficiency class Thermal efficiency of heat recovery Sound power level (Lwa) Maximum internal/external leakage rates ErP compliance Other data Filters Housing insulation, polyurethane Weight (net, without packing) Housing protection class Indoors only (heated premises) * - ePM1 70% (F7) filter is available as an accessory View from inspection side...

Open the catalog to page 4
Smart Vent - 5

Smart Vent XP Smart Vent 400 XP 395 Ordering code Electrical data Fans Electrical heater Max.power consumption Electrical preheater integrated Power connection Control board MiniMCB basic Ecodesign data Time control Local demand control Energy efficiency class Thermal efficiency of heat recovery Sound power level (Lwa) Maximum internal/external leakage rates ErP compliance Other data Filters Housing insulation, polyurethane Weight (net, without packing) Housing protection class Indoors only (heated premises) * - ePM1 70% (F7) filter is available as an accessory View from inspection side...

Open the catalog to page 5
Smart Vent - 6

Smart Vent XP Smart Vent 600 XP 579 Ordering code Electrical data Fans Electrical preheater integrated Electrical heater Max.power consumption Power connection Control board MiniMCB basic Ecodesign data Time control Energy efficiency class Local demand control Thermal efficiency of heat recovery Sound power level (Lwa) Maximum internal/external leakage rates ErP compliance Other data Filters Housing insulation, polyurethane Weight (net, without packing) Housing protection class Indoors only (heated premises) * - ePM1 70% (F7) filter is available as an accessory View from inspection side...

Open the catalog to page 6
Smart Vent - 7

Smart Vent XV Smart Vent 200 XV 182 Ordering code Electrical data Fans Electrical preheater integrated Electrical heater Max.power consumption Power connection Optional on duct Optional on duct Control board MiniMCB Time control Local demand control MiniMCB basic Ecodesign data Energy efficiency class Thermal efficiency of heat recovery Maximum internal/external leakage rates Sound power level (Lwa) Right side connection Other data Supply/Extract Housing insulation, polyurethane Left side connection Weight (net, without packing) Housing protection class Indoors only (heated premises) * -...

Open the catalog to page 7
Smart Vent - 8

Smart Vent XV Smart Vent 400 XV 50 Ordering code Electrical data Fans Electrical preheater integrated Electrical heater Max.power consumption Power connection Optional on duct Optional on duct Control board MiniMCB basic Ecodesign data Time control Thermal efficiency of heat recovery Sound power level (Lwa) Local demand control Energy efficiency class Maximum internal/external leakage rates Other data Filters Housing insulation, polyurethane Weight (net, without packing) Housing protection class Indoors only (heated premises) * - ePM1 70% (F7) filter is available as an accessory View from...

Open the catalog to page 8

All Heatmann catalogs and technical brochures

  1. CB CONTROLER

    2 Pages

  2. PRO VENT

    88 Pages