video corpo

KVE-CM
7Pages

{{requestButtons}}

Catalog excerpts

KVE-CM - 1

Halton's Continuous Mist technology provides solutions for a variety of commercial food service ventilation applications over solid fuel cooking processes. Based on Halton's patented highly efficient Capture JetTM solution and advanced mechanical KSA filter technology, the Continuous Mist feature focused on exhaust temperature reduction and ember carry over elimination. The Continuous Mist system is built into the hood's exhaust plenum. The KVE-CM Capture JetTM hood is a highly efficient kitchen ventilation hood that removes contaminated air and excess heat emitted by cooking equipment, helping to provide a comfortable and clean environment. The KVE-CM hood uses the advanced Halton Capture JetTM to improve the capture and containment of the airflows generated by the cooking equipment. Overall exhaust airflow rates can be reduced up to 30% compared to traditional kitchen hoods. The Capture JetTM hood is based on the high entrainment efficiency of a compact, high-velocity capture air jet. The capture air jets efficiently induce ambient air at the critical open sides of the hood, minimizing the spillage of the contaminated air and maintaining good air quality in the chef's work area. • Improved indoor air quality with reduced energy use. Halton Capture JetTM reduces the exhaust airflow rates required and improves the capture and containment efficiency of the hood. • Continuous mist spray. Spray is initiated when exhaust fan is turned on. • High efficiency grease filtration using UL and NSF classified Halton KSA multi-cyclone filters for removal of up to 95% of particles with a size of 8 microns per ASTM F2519. • T.A.B.TM (testing and balancing) ports, which allow accurate and effective commissioning. • Standard LED light fixtures. • Optional LED dimming is available for Capture Jet hoods. Dimming is control by a knob on the switch panel or through Halton HMI Touch Screen. • Stainless steel, welded design. NOTE: Factory must be advised of any special requirements of the Authority Having Jurisdiction at time of quote. Capture Jet™ Hood with Continuous Mist

Open the catalog to page 1
KVE-CM - 2

Description 18 Ga. Stainless steel Exhaust duct collar Capture Jet air KSA grease filters Mesh Filters %" Cold Water Inlet Solenoid 2" Drain Capture Jet Fan Mist Nozzle Manifold Construction The KVE-CM hood combines Capture JetTM, light fixtures, airflow measurement T.A.B. ports and KSA grease filters. The hood shall bear ETL or UL label. The ETL/UL listed range hood without exhaust fire damper per standard 710 and be fabricated in compliance with NFPA-96, and shall bear the NSF seal of approval. The exposed parts are manufactured from 18 ga. stainless steel. 5 The hood has double side wall...

Open the catalog to page 2
KVE-CM - 3

Noted in drawings as: * L = Length * W = Width * H = Height Estimated Crated inches Weight Shipping Weight Width_48"_75 lbs / ft. *Larger Weights - Consult Factory KVE-CM Capture Jet™ Hood with Continuous Mist

Open the catalog to page 3
KVE-CM - 4

Balancing of Capture JetTM Hoods The capture jet and exhaust air flows are easily and accurately determined by measuring the pressure difference from the T.A.B. ports mounted in each plenum. Corresponding air flows can be read from the diagrams provided. All T.A.B. readings assume cold conditions. To adjust for an exhaust temperature of 110 ºF, multiply the readings by a factor of 0.93. Exhaust air flow vs. pressure differential Capture JetTM Hood with Continuous Mist

Open the catalog to page 4
KVE-CM - 5

Capture JetTM Hood with Continuous Mist

Open the catalog to page 5
KVE-CM - 6

KVE-CM - 7.5 Filters, 2 Collars KVE-CM - 9.5 Filters, 2 Collars Capture JetTM Hood with Continuous Mist

Open the catalog to page 6
KVE-CM - 7

Suggested specifications General Kitchen hood inner liner shall be constructed from 18 gauge stainless steel where exposed. The kitchen hoods shall be supplied complete with outer casing/ main body, inner liner, exhaust duct, pressure measurement T.A.B. ports, Outer casing panels shall be constructed of stainless steel with a brushed satin finish. Each joint shall be welded and liquid tight, avoiding harmful dripping of condensation. All exposed welds are ground and polished to the original finish of metal. Canopy ends shall be double sided wall construction (no single wall hoods...

Open the catalog to page 7

All HALTON catalogs and technical brochures

  1. Halton CBD

    8 Pages

  2. FS Halton AHUs

    28 Pages

  3. Halton KCD

    3 Pages

  4. R6B

    9 Pages

  5. Halton Vario

    20 Pages

  6. Halton FDS

    7 Pages

  7. Halton FDR

    6 Pages

  8. Halton FDI

    6 Pages

  9. Halton FDE

    8 Pages

  10. Halton FDC

    5 Pages

  11. ALE/ALU

    8 Pages

  12. AHF

    5 Pages

  13. JTH

    4 Pages

  14. FDC

    5 Pages

  15. AFB

    7 Pages

  16. TCG 2013

    4 Pages

  17. FCU 2013

    6 Pages

  18. FDB2 -

    4 Pages

Archived catalogs

  1. UNIPOINT

    4 Pages

  2. HALTON-KVD

    6 Pages

  3. HALTON-KCE

    10 Pages

  4. HALTON-KSK

    6 Pages

  5. KCJ

    12 Pages