Catalog excerpts

20/KCE/xxxx/0306/EN KCE - Ventilated Ceiling with Capture Jet KCE Ventilated Ceiling with Capture Jet The KCE ventilated ceiling is a flexible solution for kitchens where heat loads are relatively low and where good indoor environmental conditions and the aesthetics of the installation are appreciated. The KCE ceiling system comprises exhaust and supply air units and Capture Jet™ units, light fitting units and ceiling panels adaptable for a great variety of space requirements. The Halton Capture Jet™ canopies can be easily integrated with the KCE ventilated ceiling in order to take care of local ventilation for cooking processes with very high heat load levels. • Draught-free air distribution into the work area from ceiling-mounted low-velocity supply units • High-efficiency grease filtration using *UL- and **NSF-classified Halton KSA multi-cyclone filters - removal of up to 95% of particles with a size of 8 microns and above • Modular construction, simplifying design, installation and maintenance • Capture Jet™ air supply integrated with supply air units, directing the excess heat and impurities released from kitchen appliances toward the exhaust air units • Stainless steel (AISI 304) design The KCE kitchen ceiling layout is designed on demand, based on the customer’s drawings and equipment list.
Open the catalog to page 1
20/KCE/xxxx/0306/EN KCE - Ventilated Ceiling with Capture Jet Construction E1: Exhaust wall model E2: Exhaust Island model E1 and E2 units are manufactured in stainless steel AISI 304 polished. Plenum roof is in galvanized steel. The exhaust units are equipped with extract spigot and damper (1), fixing holes of modules (2), electrical junction box (3), pressure measurement tape (4), light fixture IP55 (5), KSA filters KSA (6), collection tray (7) and pre-punched holes for joining module sections (8). S1: Supply 1 Capture Jet S2: Supply 2 Capture Jets The units S1 and S2 are equipped with...
Open the catalog to page 2
1 KCE - Ventilated Ceiling with Capture Jet 20/KCE/xxxx/0306/EN Function The warm, contaminated air released in the cooking process rises to ceiling level, where it is directed toward exhaust air units equipped with KSA grease filters by the capture air jets (1). Grease particles and other impurities are separated from the exhaust air in the KSA grease filters, using the cyclone separation principle. The extracted grease and other air contaminants flow into a drain channel and toward the collection tray. The supply air is introduced into the kitchen draughtfree from supply air units at low...
Open the catalog to page 3
20/KCE/xxxx/0306/EN KCE - Ventilated Ceiling with Capture Jet LIGHTING
Open the catalog to page 4
KCE - Ventilated Ceiling with Capture Jet 20/KCE/xxxx/0306/EN Light for supply air unit S2. S2 – 1000, 2 no. 2x18 w S2 – 1500, 2 no. 2x36 w S2 – 2000, 2 no. 2x58 w S2 – 1000, 1 no. 2x18 w S2 – 1500, 1 no. 2x36w S2 – 2000, 1 no. 2x58w DIMENSIONS (mm) Weights of ceiling (Kg) 15 to 20 kg / m2 ACCESSORIES SPECIAL PARTS I b 1000, 1500, 2000 700...1700
Open the catalog to page 5
20/KCE/xxxx/0306/EN KCE - Ventilated Ceiling with Capture Jet Pressure drop and sound data, exhaust Äpm1 = Pressure loss of filters measured from measuring tap, minimum exhaust pressure loss when the damper plate is open Äpm2 = Maximum exhaust pressure loss when the damper plate is nearly closed. 0,1. = Numbers of blind filter Recommended pressure loss of filter Äpm1 35-120 Pa E1 1500 E2 1000 E2 1500 E1 1000
Open the catalog to page 6
KCE - Ventilated Ceiling with Capture Jet 20/KCE/xxxx/0306/EN Pressure drop and sound data, supply Äpm1 = Measured pressure difference, Pa Äpm2 = Maximum supply pressure loss when the damper plate is nearly closed. S1 1500 S2 1000 S2 1500 S1 1000
Open the catalog to page 7
20/KCE/xxxx/0306/EN KCE - Ventilated Ceiling with Capture Jet Pressure drop and sound data, Capture Jet (S) Äpm1 = Measured pressure difference, Pa Äpm2 = Maximum supply pressure loss when the damper plate is nearly closed. 3, 4, 5 = Opening of jet (mm) S-1000 S-1500
Open the catalog to page 8
KCE - Ventilated Ceiling with Capture Jet 20/KCE/xxxx/0306/EN Suggested specifications General The kitchen ceiling shall be supplied complete with exhaust air units, supply air units, ceiling panels, pressure measurement taps, supply and exhaust air spigots with adjustment dampers, a light fitting, grease filters using the cyclone separation principle, a grease collection tray, an adjustment damper for supply air and assembly brackets. Exhaust air units Outer casing panels of exhaust air units shall be constructed from stainless steel AISI 304 with a brushed satin finish. The exhaust air...
Open the catalog to page 9
10 20/KCE/xxxx/0306/EN KCE - Ventilated Ceiling with Capture Jet Product code KCE/S-L S = Model E1 Exhaust, wall model E2 Exhaust, island model S1 Supply unit with 1 capture jet S2 Supply unit with 2 capture jets LE Integrated light CA Capture jet unit C1 Capture jet unit, 1 direction with light C2 Capture jet unit, 2 directions with light L = Length 1000, 1500, 2000 Specifics and accessories EL = Direction of duct connection S Side T Top LF = Light fittings for S2 1 1 piece 2 2 pieces Code example KCE/E1-1000 Sub products KC Kitchen ceiling panel PT/KCF = Profile T PL/KCF = Profile L J/KCE...
Open the catalog to page 10All HALTON catalogs and technical brochures
-
Halton Vita Cell Room (VCR)
2 Pages
-
Halton Rex Expander (RXP)
16 Pages
-
Halton CBD
8 Pages
-
FS Halton AHUs
28 Pages
-
Halton KCD
3 Pages
-
KVE-CM
7 Pages
-
KMC - MobiChef
5 Pages
-
Halton MobiChef
12 Pages
-
R6B
9 Pages
-
Halton Vario
20 Pages
-
Halton FDS
7 Pages
-
Halton FDR
6 Pages
-
Halton FDI
6 Pages
-
Halton FDE
8 Pages
-
Halton FDC
5 Pages
-
ALE/ALU
8 Pages
-
AHF
5 Pages
-
JTH
4 Pages
-
FDC
5 Pages
-
AFB
7 Pages
-
TCG 2013
4 Pages
-
FCU 2013
6 Pages
-
HFB - Airflow Management Damper
17 Pages
-
VHB - Active VAV Diffuser
7 Pages
-
TLD - Wall Diffuser Unit
9 Pages
-
FDB2 -
4 Pages
-
CPA - Passive Chilled Beam
13 Pages
Archived catalogs
-
FCU Vertical Fancoil Unit
4 Pages
-
Halton ? AdaptableClimate
12 Pages
-
Halton ? Ventilation fire safety
12 Pages
-
Halton ? Chilled Beams
12 Pages
-
HALTON-POLLUSTOP
4 Pages
-
UNIPOINT
4 Pages
-
HALTON-KVD
6 Pages
-
HALTON-KSK
6 Pages
-
KCJ
12 Pages
-
Halton - universal grilles
46 Pages
-
Halton - beam design guide
31 Pages