Halton CBD
8Pages

{{requestButtons}}

Catalog excerpts

Halton CBD - 1

Active Chilled Beam • Combined cooling, heating and supply air unit for flush installation within suspended ceiling • Comprises an integral recirculation air path • Well suited for spaces with high cooling loads, low humidity load and low ventilation requirement • Ideal for a wide range of buildings, where high quality environmental conditions and individual room control are required • Typical applications: office rooms, landscape offices, meeting rooms, hotel guest rooms and patient care rooms etc. MATERIAL AND FINISHING Product Models & Accessories • Model with combined cooling and heating coil • Options for duct and water pipe connections Material and finishing Cooling/heating water pipe connections are Cu15/Cu10 with a wall thickness of 1.0 mm, fulfilling the European Standard EN 1057:1996. The maximum operating pressure for chilled/hot water pipework is 1.0 MPa. Supply air duct connection is D100 mm. CBD - Active Chilled Beam Hatton i

Open the catalog to page 1
Halton CBD - 2

QUICK SELECTION Leff Effective length, length of cooling coil, mm Pa Supply air capacity, W DPtot Chilled beam chamber pressure, Pa Lmin Minimum distance between central lines of two supply units, m Ld Distance where supply air jet detaches from the ceiling, m Chilled water inlet temperature (Twin) = 15 °C Chilled water outlet temperature (Twout) = 17 °C Supply air temperature (Ta) = 18 °C A-weighted sound pressure level, reduced by total equivalent absorption surface of 10m2 , dB(A) red 10m2 sab < 35 dB(A) PRODUCT MODELS AND ACCESSORIES ACCESSORY MODEL CBD - Active Chilled Beam

Open the catalog to page 2
Halton CBD - 3

The primary supply air enters the plenum of the active chilled beam, from where it is diffused into the room through nozzles and supply slots located at the bottom of the beam. The supply air nozzle jets induce efficiently ambient room air through the heat exchanger, where it is either cooled or heated. The supply air jet is directed horizontally along the ceiling surface. Four different nozzle sizes are available to enable different supply airflow rates. The cooling and heating capacities of the chilled beam are controlled by regulating the water flow rate according to the control signal...

Open the catalog to page 3
Halton CBD - 4

Servicing CODE DESCRIPTION 1 Bottom panel 8 Chilled & hot water pipe connections Open the bottom panel of the chilled beam. Clean the supply air plenum, duct and finned coils of the heat exchanger using a vacuum cleaner, taking care not to damage the finned coils. Clean the bottom panel and, if required, the side plates using a damp cloth. Cooling The recommended cooling water mass flow rate is 0.03 - 0.10 kg/s, resulting in a temperature rise of 1 - 3°C in the heat exchanger. To avoid condensation the recommended inlet water temperature of the heat exchanger is 14 - 16°C. Heating The...

Open the catalog to page 4
Halton CBD - 5

Cooling: nozzle A qv Leff Heating: nozzle B Recommended maximum linear meter heating capacity in 80-120 Pa pressure level is 200 W/m. CBD - Active Chilled Beam Halton

Open the catalog to page 5
Halton CBD - 6

Cooling: nozzle C qv Leff Heating: nozzle D Recommended maximum linear meter heating capacity in 80-120 Pa pressure level is 300 W/m. CBD - Active Chilled Beam Halton

Open the catalog to page 6
Halton CBD - 7

Notations of the selection tables LpA values presented with room attenuation 4 dB (red 10m2 - sab). When using room attenuation 8 dB (red 25m2 - sab): LpA - 4dB. Leff Effective length, length of cooling coil, mm DPtot Chilled beam chamber pressure, Pa LpA A-weighted sound pressure level, reduced by total equivalent absorption surface of 10m2, dB(A) red 10m2 - sab Lmin Minimum distance between central lines of two supply units, m Ld Distance from the supply unit, at which air jet detaches from ceiling, m Chilled water inlet temperature (Twin) = 15 °C Chilled water outlet temperature (Twout)...

Open the catalog to page 7
Halton CBD - 8

The active chilled beam shall have an integral recirculation air path through the perforated bottom panel. The bottom panel shall be openable and demountable from either side for general maintenance and cleaning. The bottom panel shall be removable without using any special tools. The air supply shall be bi-directional. The active chilled beam shall be 295mm wide and 240mm high. The active chilled beams shall have an inlet duct diameter of 100 mm. The frame, bottom and side panels shall be made of galvanised steel plate. All visible parts shall be white RAL 9010 20% gloss. All pipes shall...

Open the catalog to page 8

All HALTON catalogs and technical brochures

  1. FS Halton AHUs

    28 Pages

  2. Halton KCD

    3 Pages

  3. KVE-CM

    7 Pages

  4. R6B

    9 Pages

  5. Halton Vario

    20 Pages

  6. Halton FDS

    7 Pages

  7. Halton FDR

    6 Pages

  8. Halton FDI

    6 Pages

  9. Halton FDE

    8 Pages

  10. Halton FDC

    5 Pages

  11. ALE/ALU

    8 Pages

  12. AHF

    5 Pages

  13. JTH

    4 Pages

  14. FDC

    5 Pages

  15. AFB

    7 Pages

  16. TCG 2013

    4 Pages

  17. FCU 2013

    6 Pages

  18. FDB2 -

    4 Pages

Archived catalogs

  1. UNIPOINT

    4 Pages

  2. HALTON-KVD

    6 Pages

  3. HALTON-KCE

    10 Pages

  4. HALTON-KSK

    6 Pages

  5. KCJ

    12 Pages