Transport Anchor System Civil Engineering
50Pages

{{requestButtons}}

Catalog excerpts

Transport Anchor System Civil Engineering - 1

TRANSPORT ANCHOR SYSTEM CIVIL ENGINEERING This catalogue conforms to the installation and application instructions according to the VDI/BV-BS 6205 guidelines

Open the catalog to page 1
Transport Anchor System Civil Engineering - 2

D EH A L I F TI N G A NCHO R S YS TE M F OR U SE IN CIVIL EN GINEER ING Product Information Certified quality from HALFEN – Connect to safety. HALFEN Spherical head anchors meet the requirements of the European machine guideline (MD) 2006/42/EC. The required steel load capacity for lifting systems is defined in these guidelines. To also ensure safe use of lifting anchor systems with the required resistance values for cast-in anchors, HALFEN Lifting anchor and lifting anchor systems also meet the requirements of VDI/BV-BS regulation 6205. The regulation titled “Lifting anchor and Lifting...

Open the catalog to page 2
Transport Anchor System Civil Engineering - 3

D EH A L I F TI N G A NCHO R S YS TE M F OR U SE IN CIVIL EN GINEER ING Contents System overview - System overview Conical pipe anchor system Recess fillers Safety regulations for lifting anchor systems Selecting the lifting anchor system Product range Quick-fitting (action) anchor DSM in pipes Dimensions of the DSM anchors Load capacities of the DSM anchors Spherical head lifting anchor in shafts Dimensions of the spherical head lifting anchor in shafts Load capacities of the spherical head lifting anchor in shafts Anchors in shafts Quick-fitting spherical head anchors DSM in shafts...

Open the catalog to page 3
Transport Anchor System Civil Engineering - 4

D EH A L I F TI N G A NCHO R S YS TE M F OR U SE IN CIVIL EN GINEER ING System Overview DEHA Spherical head anchors Spherical head anchor Spherical head rod anchor Narrow foot spherical head anchor DSM Quick fitting spherical head anchor suitable for pipes and shaft elements Load class suitable for thin-walled shaft elements for use in shaft walls and precast easy and safe to use, especially elements with high concrete when used in difficult to access strengths formwork Conical-pipe anchor for use in pipes with increased concrete cover DKR Conical pipe anchor (shaft) DKR Plastic sealing...

Open the catalog to page 4
Transport Anchor System Civil Engineering - 5

D EH A L I F TI N G A NCHO R S YS TE M F OR U SE IN CIVIL EN GINEER ING System Overview Recess-formers and accessories Rubber recess former, round Steel recess former, round Magnetic steel recess former, round Rubber recess former, narrow for all spherical head anchors excluding DSM Quick-fitting (action) and pitching anchors for all spherical head anchors for all spherical head anchors in excluding DSM Quick-fitting metal formwork excluding (action) and pitching anchors pitching anchors and DSM for all spherical head anchors excluding DSM Quick-fitting (action) and pitching anchors Special...

Open the catalog to page 5
Transport Anchor System Civil Engineering - 6

D EH A L I F TI N G A NCHO R S YS TE M F OR U SE IN CIVIL EN GINEER ING Conical Pipe Anchor System Product information Solution: The DEHA Conical pipe anchor system In some cases reinforced concrete pipes require a larger concrete cover for all metal elements. This can only be achieved with the standard lifting anchor if the anchor is cast deeper in the concrete. The larger concrete cover results in deeper recesses especially for anchors of load class 20.0 and 32.0. Reusable DKR Adapter-head The DKR Adapter-head matches the lifting link used (universal head lifting link as well as the...

Open the catalog to page 6
Transport Anchor System Civil Engineering - 7

D EH A L I F TI N G A NCHO R S YS TE M F OR U SE IN CIVIL EN GINEER ING Recess Void Fillers Recess void fillers for DKR Anchors and spherical head-lifting-anchor Fibre reinforced concrete fillers used in combination with the DKR Anchor system are watertight up to water pressures of 5 bar if a suitable adhesive for this pressure is used. water column 50 m Tested by the Institut für Kanaltechnik (Institute for Pipe Technology) in Gelsenkirchen, Germany Applicable load classes for the recess fillers 7.5 Load class no special requirements on watertightness Advantages of the recess filler: •...

Open the catalog to page 7
Transport Anchor System Civil Engineering - 8

D EH A L I F TI N G A NCHO R S YS TE M F OR U SE IN CIVIL EN GINEER ING Installation and Application Instructions Safety regulations apply to mass-produced lifting anchors and systems for transporting prefabricated concrete elements with lifting systems. A lifting system as defined in the safety regulations as the combination of precast concrete with permanent cast-in anchors and the temporarily attached lifting device. Lifting and anchoring systems must be constructed for their intended use; a safe, reliable lifting of precast elements. Construction approvals issued by the German Institute...

Open the catalog to page 8
Transport Anchor System Civil Engineering - 9

D EH A L I F TI N G A NCHO R S YS TE M F OR U SE IN CIVIL EN GINEER ING Installation and Application Instructions Lif ting anchor application The load capacity of lifting anchors is dependant on the dimensions of the finished component, edge clearance, the type of lifting anchors and their positions and the concrete quality (concrete strength at time of first lift). The loads acting on the anchors increase when using a hoist. An increase in the angle-spread results in greater stress on the anchors and cables. When selecting a lifting anchor the influence of the hoist is taken into account...

Open the catalog to page 9
Transport Anchor System Civil Engineering - 10

D EH A L I F TI N G A NCHO R S YS TE M F OR U SE IN CIVIL EN GINEER ING Installation and Application Instructions Lifting device The load capacity of the hoisting gear depends on the rated capacity of the attached universal head lifting link. All lifting links must be checked by an expert at least once a year. A record of these checks must be kept. The “code of practice for cables, chains and hoists used in the construction industry” as defined in the Building trade association regulations must be observed. Unloading on site Check all pipes, pipe parts and seals on delivery (compare to DIN...

Open the catalog to page 10
Transport Anchor System Civil Engineering - 11

D EH A L I F TI N G A NCHO R S YS TE M F OR U SE IN CIVIL EN GINEER ING Product Range Spherical head anchor: load class 7.5 - 45.0 Spherical head anchor: load class 1.3 - 5.0 Load class Load class Article number • hot-dipped galvanised mill finish hot-dipped galvanised mill finish Order no. 0735.010- Article number Article number Article number Load charts are available for articles marked with a (•). Load class • Stainless steel Article number 6000-1,3-0065 A4 Other lengths and stainless steel A4 on request. Minimum orders and delivery times on request.

Open the catalog to page 11