Introduction
The document discusses the HALFEN HDB Shear Rail system, which addresses punching shear issues in reinforced concrete slabs without beams or enlarged column heads. This system is cost-effective, reduces formwork costs, and optimizes space usage.
System Description
HDB Shear Rails consist of double-headed studs welded onto a spacer-bar, providing slippage-free anchorage that minimizes shear cracks. They are more effective than traditional stirrups, especially under higher loads.
Advantages
- Simple and quick installation
- Reduced build-time
- No caging required
- Approved for use in various elements and under non-static loads
- European-wide approval ensures safety and compliance
Installation and Planning
HDB Shear Rails are installed after the main reinforcement, simplifying the process and ensuring correct concrete cover. They are suitable for both precast and semi-precast elements.
Technical Specifications
The document provides detailed calculations for verifying shear load capacity according to EN 1992-1-1:2011-01 and the European Technical Approval ETA-12/0454. It includes formulas for determining effective shear stress and punching shear resistance.
Design Principles
The design concept is based on improved safety standards, with specific equations for calculating shear reinforcement requirements. The document outlines necessary parameters for ensuring adequate reinforcement, including stud spacing and load increase factors.
Conclusion
The HALFEN HDB Shear Rail system offers a reliable and efficient solution for reinforcing concrete slabs against punching shear, with proven higher load-bearing capacity and compliance with European standards.
Overview
The document provides detailed technical specifications and guidelines for the HALFEN HDB and HDB-S shear rail systems, enhancing the structural integrity of flat slabs, foundation slabs, and beams by reinforcing areas susceptible to punching shear and shear forces.
Specifications
Includes tables detailing dimensions and configurations of shear rails, such as stud diameter, height, number of studs per element, and element length. Specifies the material used, ribbed or smooth reinforcement steel B 500, and provides technical approval references like ETA-12/0454 and RAL-GZ 658/2.
Installation Procedures
Outlines installation methods for both precast and semi-precast slabs, using clip bars and spacers for proper installation and alignment. Installation can be done from above or below, depending on the slab type and reinforcement configuration.
Standards and Approvals
The shear rail systems comply with European Technical Approvals and are approved by the quality control association for anchorage and reinforcement technology. References EN 1992-1-1:2011-1 for concrete cover dimensions and other relevant standards.
Recommendations
Recommends using higher spacers during storage and transport of semi-precast slabs to accommodate protruding shear rails. Suggests verifying shear force transfer in precast slab joints according to EN 1992-1-1.
Product Advantages
HALFEN HDB-F shear rails are highlighted for ease of installation and efficiency in reducing production time by up to 50%. Emphasizes system flexibility, allowing for independent installation of lower reinforcement and easy alignment of spacers.
Contact Information
Provides contact details for HALFEN subsidiaries and distributors worldwide, ensuring accessibility for further inquiries and support.
See more

Catalog excerpts

HDB Shear Rail-1

HALFEN SHEAR RAIL Punching shear reinforcement calculation according to European Technical Approval ETA-12/0454

 Open the catalog to page 1
HDB Shear Rail-2

HALFEN HDB SHEAR RAIL ‒ PUNCHING SHEAR REINFORCEMENT System Description - HDB Shear Rails as Punching Shear Reinforcement Point-load supported slabs with no enlarged column heads Reinforced concrete slabs with no beams and no enlarged column heads are inexpensive to manufacture and provide good conditions for optimal use of space and further constructionwork without obstructions. Particular advantages are: • low formwork costs • no obstructions to further construction (piping, ventilation ducts) under the slab • oor heights can often be reduced The problem: punching shear verication around columns...

 Open the catalog to page 2
HDB Shear Rail-3

HALFEN HDB SHEAR RAIL ‒ PUNCHING SHEAR REINFORCEMENT Introduction Advantages of HDB Shear rails Installation: • simple and quick installation • reduced build-time • no caging required as with stirrup reinforcement • installed after placing the main upper and lower longitudinal reinforcement Planning: • building authority approved as punching shear reinforcement in slabs, foundation slabs and footings • HDB Shear rails can also be used in precast elements and semi-precast elements • also approved for non- predominantly static loads • standardised product range for typical dimensions Safety: •...

 Open the catalog to page 3
HDB Shear Rail-4

HALFEN HDB-S SHEAR RAIL ‒ SHEAR REINFORCEMENT System Description - HDB Shear Rails as Shear Reinforcement Linear supported slabs — Verication of shear load capacity Shear load capacity for reinforced concrete slabs must be veried according to EN 1992-1-1:2011-01 in all shear cross-sections. The regulations according to the National Annex must also be observed. Shear failure near support Support with HDB-S Shear reinforcement The problem: complex installation of shear reinforcement According to EN 1992-1-1:2011-01, high-load slabs (VEd > ⅓ × VRd,max) require stirrup reinforcement to be calculated...

 Open the catalog to page 4
HDB Shear Rail-5

HALFEN HDB-S SHEAR RAIL ‒ SHEAR REINFORCEMENT Introduction Advantages of the HDB-S Shear rails Installation: • simple and quick installation • reduced build-time • no caging required as with stirrup reinforcement • installed after placing the upper and lower longitudinal reinforcement Planning: • HDB Shear rails can also be used in precast elements and semi-precast elements • also approved in Germany for non- predominantly static loads • standardised product range for typical dimensions Safety: • simple visual control of installed elements • negligible slippage of anchorage in the shear reinforcement...

 Open the catalog to page 5
HDB Shear Rail-6

HALFEN HDB / HDB-S SHEAR RAIL ‒ PUNCHING SHEAR / SHEAR REINFORCEMENT Introduction The product as punching shear and shear reinforcement Double-headed stud Is made of reinforcing steel B 500 (smooth or ribbed): supplied in Ø dA 10 - 12 - 14 - 16 - 18 - 20 - 25 mm The stud head diameter is 3 times the bar diameter dA: dK = 3 · dA HDB Elements The double-headed studs are connected using a welded-on spacer-bar. Clip bars are used to secure the spacer-bar to the reinforcement. Clip bars can be attached anywhere on the spacer-bar (order separately, see page 23). Two variants HDB System elements • available...

 Open the catalog to page 6
HDB Shear Rail-7

HALFEN HDB SHEAR RAIL ‒ PUNCHING SHEAR REINFORCEMENT Calculation: Basic Principles Point-load supported slabs with no enlarged column heads Design concept in accordance with EN 1992-1-1:2011-01 (Eurocode 2) EN 1992-1-1:2011-01 determines the maximum punching shear capacity for at slabs analogically to the strength of the compression strut of beams. However, test evaluations prove that this method is not applicable for at slabs. Particularly in tests using stirrups as punching shear reinforcement, the level of safety required by EN 1990:2010-12 was not achieved. This is why an improved design...

 Open the catalog to page 7
HDB Shear Rail-8

HALFEN HDB SHEAR RAIL ‒ PUNCHING SHEAR REINFORCEMENT Calculation: Basic Principles Verication outside of the punching shear reinforced area (Longitudinal reinforcement in the column width area increased each side by 3dm, compare with no. 7 on page 10) fck = characteristic concrete compressive strength fcd = design value for concrete compressive strength fyd = design yield strength for reinforcement steel no punching shear reinforcement necessary outermost stud punching shear reinforcement necessary uout The empirical pre-factor CRd,c is dependent on the respective column perimeter u0 / dm and...

 Open the catalog to page 8
HDB Shear Rail-9

HALFEN HDB SHEAR RAIL ‒ PUNCHING SHEAR REINFORCEMENT Design: Basic Principles 4. Calculating the required punching shear Stud spacing reinforcement Apart from the static relevant boundary conditions, further geometric specications have to be observed when placing studs and elements: Required punching shear reinforcement in region C As,req = VEd · β · η/fyd • the distance of the rst stud from the column edge must be between 0.35 dm and 0.50 dm • maximum studs spacing in radial direction must be ≤ 0.75 dm • maximum tangential anchors spacing at a distance of 1.0 d from the column edge must be ≤...

 Open the catalog to page 9
HDB Shear Rail-10

HALFEN HDB SHEAR RAIL ‒ PUNCHING SHEAR REINFORCEMENT Calculation: Basic Principles 1.5 dm Additionally for wall ends and wall corners, the following generic load factors can be used: = 1.35 for wall ends = 1.20 for wall corners The more precise method of assuming a plastic shear distribution as in EN 1992-1-1:2011-01 can be used as an alternative or as soon as the span width of adjoining slabs deviate more than 25% from one another. Minimum bar lengths — example for interior column Bar length lbar = b + 2 · ls + 2 · 1.5 dm + 2 · lbd ≥ b + 2 · 3 dm + 2 · lbd = anchorage length according to EN...

 Open the catalog to page 10
HDB Shear Rail-11

HALFEN HDB SHEAR RAIL ‒ PUNCHING SHEAR REINFORCEMENT Calculation: Basic Principles Case 1 Rectangular interior column with: b ≤ a ≤ 2b and (a + b) · 2 ≤ 12 dm dm = mean effective static depth Recommended load factor is β = 1.15 Case 6 Circular edge column 2.0 dm Recommended load factor β = 1.4 Case 7 Circular corner column Case 2 Rectangular edge column Edge parallel to a with: Recommended load factor β = 1.5 Recommended load factor is β = 1.4 Case 8 Wall corner Case 3 Rectangular edge column Edge parallel to b Recommended load factor β = 1.2 Recommended load factor β = 1.4 Recommended load factor...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.