HALFEN HIT Insulated Connection
148Pages

{{requestButtons}}

Catalog excerpts

HALFEN HIT Insulated Connection - 1

IT plete H The com nnections o dc insulate ! ct range produ HALFEN HIT INSULATED CONNECTION • further certifications by the Passive House Institute for height off set elements • with European Technical Appro

Open the catalog to page 1
HALFEN HIT Insulated Connection - 2

Be on the safe side. We take fire protection seriously. The fully enclosed HIT-HP and HIT-SP ensure compliance with the highest fire safety requirements in accordance with REI 120 according to EN 13501 as well as classification F120-AB according to DIN 4102 in compliance with ETA-13/0546 and numerous other approvals. This is made possible by the special shape of the insulation in combination with the use of high-quality nonflammable mineral wool, Building Material Class A1 and Euro Class A1, respectively. Additional fire protection measures, e.g. circumferential fire barrier or additional lintel...

Open the catalog to page 2
HALFEN HIT Insulated Connection - 3

HALFEN HIT INSULATED CONNECTION Contents The benefits of HIT-HP High Performance & HIT-SP Superior Performance Type overview Product description Chapter 1 Chapter 2 Chapter 3 Chapter 4 Chapter 5 Chapter 6 – HIT-HP MV, HIT-SP MV – HIT-HP MD, HIT-SP MD – HIT-HP COR, HIT-SP COR – HIT-HP MV-OU/OD, HIT-SP MV-OU/OD – HIT-HP ZV, HIT-SP ZV – HIT-HP ZD, HIT-SP ZD – HIT-HP DD, HIT-SP DD – HIT-HP ZZ-HT, HIT-SP ZZ-HT – HIT-HP DD-AT, HIT-SP DD-AT – HIT-HP DV-FT, HIT-SP DV-FT – HIT-HP MV-OT, HIT-SP MV-OT – HIT-ST, HIT-WT ! N EW ! N EW ! N EW ! N EW Building physics, Technical Information Chapter 8 –...

Open the catalog to page 3
HALFEN HIT Insulated Connection - 4

HALFEN HIT INSULATED CONNECTION HIGH & SUPERIOR PERFORMANCE General HALFEN HIT Insulated connection – always a good decision HALFEN has done a lot to further improve the successful first generation of HIT. The following is a summary of the most important benefits available to you with the HIT-HP MV and HIT-SP MV. HP stands for High Performance with an insulation thickness of a 80 mm and SP means Superior Performance with an insulation thickness of 120 mm. Convince yourself of the benefits in your next project. Thermal Insulation Effective thermal separation of the balcony slab Compliant with...

Open the catalog to page 4
HALFEN HIT Insulated Connection - 5

HALFEN HIT INSULATED CONNECTION HIGH & SUPERIOR PERFORMANCE General Further advantages at a glance Fire protection • REI 120 (F120) as standard for all HIT-HP and HIT-SP elements • non-flammable insulation material: Building material class A1 • no additional fire boards required • no mix-up of elements, with and without fire protection requirements • no additional installation time or work for REI 120 (F120) • robust plastic casing with 3D fixing of all structural members RAL quality symbol With RAL Quality Mark Anchoring and Reinforcement technology RAL-GZ 658/2 awarded by RAL Quality control...

Open the catalog to page 5
HALFEN HIT Insulated Connection - 6

Product Over view – Thermally insulated connections Cantilevered balcony slabs One part application HIT-HP MV / HIT-SP MV • transfers bending moments and shear forces • insulation thickness 80 mm / 120 mm → page 11 Main slab HIT-HP MV HIT- SP MV Balcony Balcony Main slab Multi-part application HIT-HP MV-ES / HIT-SP MV-ES • product type for element slabs • transfers bending moments and shear forces • insulation thickness 80 mm / 120 mm → page 11 HIT-HP MV-ES HIT- SP MV-ES Balcony Main slab Balcony Main slab 5 Application for cantilevered balcony slabs Technical Information Main slab Main...

Open the catalog to page 6
HALFEN HIT Insulated Connection - 7

Cantilevered balcony slabs with height offset or wall connections HIT-HP MV-OU / HIT-SP MV-OU • height offset, balcony higher than main slab • upward wall connection • transfers bending moments and shear forces • insulation thickness 80 mm / 120 mm → page 52 HIT-HP MV-OU HIT- SP MV-OU Main slab Product Over view – Thermally insulated connections Main slab HIT-HP MV-OD HIT- SP MV-OD Balcony HIT-HP MV-OD / HIT-SP MV-OD • height offset, balcony lower than main slab • downward wall connection • transfers bending moments and shear forces • insulation thickness 80 mm / 120 mm →page 52...

Open the catalog to page 7
HALFEN HIT Insulated Connection - 8

Product Over view – Thermally insulated connections Simply-supported balcony slabs on columns HIT-HP ZD / HIT-SP ZD • transfers positive and negative shear forces • insulation thickness 80 mm / 120 mm → page 73 Main slab HIT-±BQZD HIT-HP HIT-SP ZD 3 HIT-HP ZD / HIT-SP ZD without CSB • transfers positive and negative shear forces • insulation thickness 80 mm / 120 mm → page 73 Main slab Main slab Continuous slabs Main slab HIT-HP DD / HIT-SP DD • transfers bending moments and positive and negative shear forces • insulation thickness 80 mm / 120 mm → page 85 HIT-HP ZD HIT-SP ZD (without CSB)...

Open the catalog to page 8
HALFEN HIT Insulated Connection - 9

HIT-HP DD-AT, HIT-SP DD-AT Forms a thermal barrier between parapet and main slab for selective use. Unit spacing based on structural requirements. • insulation thickness 80 mm / 120 mm →page 99 Main slab Main slab HIT-HP DD-AT HIT-SP DD-AT Corbelled HIT-FT In-situ thermal insulation parapet HIT-FT HIT-HP MV-OT, HIT-SP MV-OT Main slab Forms a thermal barrier between corbel and main slab for selective use. Unit spacing based on structural requirements. • insulation thickness 80 mm / 120 mm → page 114 In-situ thermal insulation DD HIT-HP MD-OT HIT-HP MDX-OT HIT-SP MDX-OT HIT-SP MD-OT Main...

Open the catalog to page 9
HALFEN HIT Insulated Connection - 10

HALFEN HIT INSULATED CONNECTION HIGH & SUPERIOR PERFORMANCE Material specification Tension bars Flash butt welded bar connection, consisting of a combination of two reinforcing steel bars B500B according to DIN 488 and a stainless bar steel of strength class S 690 Shear bars Stainless bar steel of strength B500NR or flash butt welded bars connection, consisting of a combination of stainless bar steel B500NR and reinforcing steel bars B500B Compression shear bearings High-performance mortar with increased compressive and tensile strength as well as optimized thermal conductivity Insulating...

Open the catalog to page 10
HALFEN HIT Insulated Connection - 11

HALFEN HIT INSULATED CONNECTION HIGH & SUPERIOR PERFORMANCE CSB (C€ Balcony connection for cantilevered balcony slabs Transfers bending moments and shear forces Standard design: HIT-HP MV - High Performance with insulation thickness 80 mm HIT-SP MV - Superior Performance with insulation thickness 120 mm HIT-HP MV-ES - High Performance for element slabs HIT-SP MV-ES - Superior Performance for element slabs Application: Cantilevered balcony Available widths Content Type Page The basics on load bearing capacity HIT-HP MV, IIII SP MV 12 Product types HIT-HP MV, HIT-SP MV 13 Load bearing...

Open the catalog to page 11

All HALFEN catalogs and technical brochures

  1. HBJ Betojuster

    12 Pages

  2. Stud Connector

    20 Pages

  3. HDB Shear Rail

    28 Pages

  4. HLB Loop Box

    20 Pages

  5. Product Range

    28 Pages

  6. Facade

    16 Pages

  7. Imagebrochure

    10 Pages