1. Catalogs
  2. HALFEN
  3. HALFEN HIT Insulated Connection

HALFEN HIT Insulated Connection

HALFEN HIT Insulated Connection
1 / 148 PagesView full catalog

HALFEN HIT Insulated Connection

Product catalog summary
Overview: The document provides comprehensive technical information on the HALFEN HIT Insulated Connection system, focusing on the HIT 16-E model. It emphasizes compliance with European Technical Approval and certifications by the Passive House Institute, highlighting the importance of fire protection and the use of high-quality, non-flammable materials.
Specifications: The HIT-HP (High Performance) and HIT-SP (Superior Performance) units feature insulation thicknesses of 80 mm and 120 mm, respectively. They comply with REI 120 fire safety standards and are made from mineral wool, classified as Building Material Class A1.
Product Benefits: The HIT system offers enhanced thermal insulation, reduced tension bar cross-section, and a significant reduction of penetration points. It is certified by the Passive House Institute and approved by various technical authorities, ensuring effective thermal separation and fire protection.
Installation and Functionality: HIT elements are easy to install, do not require welded assembly bars, and provide optimal protection against mechanical loads and moisture. The system supports shear forces up to 160 kN/m with a slab thickness of at least 16 cm.
Fire Protection: The HIT-HP and HIT-SP units act as fire barriers, ensuring compliance with the highest fire safety requirements, eliminating the need for additional fire boards, and reducing installation time.
Certifications and Approvals: The product is CE marked, DIBt-approved, and type-tested. It includes a RAL Quality Mark for anchoring and reinforcement technology, ensuring compliance with technical product requirements.
Technical Information: Detailed chapters cover various HIT product types, their applications, and technical specifications. Information on building physics, including thermal insulation, fire protection, and noise reduction, is provided.
Software and Support: HALFEN offers user-friendly software for design and optimization, along with technical support and tender specifications.
Introduction: The document discusses the load-bearing behavior of HALFEN's HIT-HP MV and HIT-SP MV insulated cantilever slab connections, utilizing the innovative C S B Compression Shear Bearing system, which replaces traditional materials with ultra-high strength fiber-reinforced mortar.
Specifications and Approvals: The HIT-HP and HIT-SP systems are incorporated into a National Technical Approval, including ETA-13/0546, simplifying the verification process for structural engineers.
Load Bearing Capacities: Detailed load-bearing capacities are provided for various concrete strength classes and concrete covers, aiding in the selection and planning of connector lengths.
Structural Behavior and Software: C S B technology allows for increased moment bearing capacity. HALFEN provides software to optimize the load range selection for HIT elements.
Design and Ordering: Ordering examples and possible combinations of tension bars and compression shear bearings are included, with custom designs available upon request.
Technical Data and Calculations: Tables and diagrams provide design values for moment and shear capacities according to EN 1992-1-1 (EC2).
Conclusion: HALFEN's HIT-HP and HIT-SP systems offer advanced solutions for insulated cantilever slab connections, backed by comprehensive technical approvals and detailed load-bearing data.
Thermal Insulation and Energy Saving: The document outlines methods for calculating thermal bridges, essential for maintaining compliance with energy regulations and ensuring efficient building design.
Fire Resistance and Insulation: The document highlights the advantages of using fire-resistant insulating wool, maintaining heat insulation efficiency, and providing weather protection.
HIT Software Features: The HIT software simplifies the design and ordering process for balcony connections, offering a user-friendly interface and verifiable structural calculations.
See more

Catalog excerpts

HALFEN HIT Insulated Connection-1

IT plete H The com nnections o dc insulate ! ct range produ HALFEN HIT INSULATED CONNECTION • further certifications by the Passive House Institute for height off set elements • with European Technical Appro

 Open the catalog to page 1
HALFEN HIT Insulated Connection-2

Be on the safe side. We take fire protection seriously. The fully enclosed HIT-HP and HIT-SP ensure compliance with the highest fire safety requirements in accordance with REI 120 according to EN 13501 as well as classification F120-AB according to DIN 4102 in compliance with ETA-13/0546 and numerous other approvals. This is made possible by the special shape of the insulation in combination with the use of high-quality nonflammable mineral wool, Building Material Class A1 and Euro Class A1, respectively. Additional fire protection measures, e.g. circumferential fire barrier or additional lintel fire...

 Open the catalog to page 2
HALFEN HIT Insulated Connection-3

HALFEN HIT INSULATED CONNECTION Contents The benefits of HIT-HP High Performance & HIT-SP Superior Performance Type overview Product description Chapter 1 Chapter 2 Chapter 3 Chapter 4 Chapter 5 Chapter 6 – HIT-HP MV, HIT-SP MV – HIT-HP MD, HIT-SP MD – HIT-HP COR, HIT-SP COR – HIT-HP MV-OU/OD, HIT-SP MV-OU/OD – HIT-HP ZV, HIT-SP ZV – HIT-HP ZD, HIT-SP ZD – HIT-HP DD, HIT-SP DD – HIT-HP ZZ-HT, HIT-SP ZZ-HT – HIT-HP DD-AT, HIT-SP DD-AT – HIT-HP DV-FT, HIT-SP DV-FT – HIT-HP MV-OT, HIT-SP MV-OT – HIT-ST, HIT-WT ! N EW ! N EW ! N EW ! N EW Building physics, Technical Information Chapter 8 – Basics...

 Open the catalog to page 3
HALFEN HIT Insulated Connection-4

HALFEN HIT INSULATED CONNECTION HIGH & SUPERIOR PERFORMANCE General HALFEN HIT Insulated connection – always a good decision HALFEN has done a lot to further improve the successful first generation of HIT. The following is a summary of the most important benefits available to you with the HIT-HP MV and HIT-SP MV. HP stands for High Performance with an insulation thickness of a 80 mm and SP means Superior Performance with an insulation thickness of 120 mm. Convince yourself of the benefits in your next project. Thermal Insulation Effective thermal separation of the balcony slab Compliant with requirements...

 Open the catalog to page 4
HALFEN HIT Insulated Connection-5

HALFEN HIT INSULATED CONNECTION HIGH & SUPERIOR PERFORMANCE General Further advantages at a glance Fire protection • REI 120 (F120) as standard for all HIT-HP and HIT-SP elements • non-flammable insulation material: Building material class A1 • no additional fire boards required • no mix-up of elements, with and without fire protection requirements • no additional installation time or work for REI 120 (F120) • robust plastic casing with 3D fixing of all structural members RAL quality symbol With RAL Quality Mark Anchoring and Reinforcement technology RAL-GZ 658/2 awarded by RAL Quality control association...

 Open the catalog to page 5
HALFEN HIT Insulated Connection-6

Product Over view – Thermally insulated connections Cantilevered balcony slabs One part application HIT-HP MV / HIT-SP MV • transfers bending moments and shear forces • insulation thickness 80 mm / 120 mm → page 11 Main slab HIT-HP MV HIT- SP MV Balcony Balcony Main slab Multi-part application HIT-HP MV-ES / HIT-SP MV-ES • product type for element slabs • transfers bending moments and shear forces • insulation thickness 80 mm / 120 mm → page 11 HIT-HP MV-ES HIT- SP MV-ES Balcony Main slab Balcony Main slab 5 Application for cantilevered balcony slabs Technical Information Main slab Main slab...

 Open the catalog to page 6
HALFEN HIT Insulated Connection-7

Cantilevered balcony slabs with height offset or wall connections HIT-HP MV-OU / HIT-SP MV-OU • height offset, balcony higher than main slab • upward wall connection • transfers bending moments and shear forces • insulation thickness 80 mm / 120 mm → page 52 HIT-HP MV-OU HIT- SP MV-OU Main slab Product Over view – Thermally insulated connections Main slab HIT-HP MV-OD HIT- SP MV-OD Balcony HIT-HP MV-OD / HIT-SP MV-OD • height offset, balcony lower than main slab • downward wall connection • transfers bending moments and shear forces • insulation thickness 80 mm / 120 mm →page 52 Simply-supported...

 Open the catalog to page 7
HALFEN HIT Insulated Connection-8

Product Over view – Thermally insulated connections Simply-supported balcony slabs on columns HIT-HP ZD / HIT-SP ZD • transfers positive and negative shear forces • insulation thickness 80 mm / 120 mm → page 73 Main slab HIT-±BQZD HIT-HP HIT-SP ZD 3 HIT-HP ZD / HIT-SP ZD without CSB • transfers positive and negative shear forces • insulation thickness 80 mm / 120 mm → page 73 Main slab Main slab Continuous slabs Main slab HIT-HP DD / HIT-SP DD • transfers bending moments and positive and negative shear forces • insulation thickness 80 mm / 120 mm → page 85 HIT-HP ZD HIT-SP ZD (without CSB) Technical...

 Open the catalog to page 8
HALFEN HIT Insulated Connection-9

HIT-HP DD-AT, HIT-SP DD-AT Forms a thermal barrier between parapet and main slab for selective use. Unit spacing based on structural requirements. • insulation thickness 80 mm / 120 mm →page 99 Main slab Main slab HIT-HP DD-AT HIT-SP DD-AT Corbelled HIT-FT In-situ thermal insulation parapet HIT-FT HIT-HP MV-OT, HIT-SP MV-OT Main slab Forms a thermal barrier between corbel and main slab for selective use. Unit spacing based on structural requirements. • insulation thickness 80 mm / 120 mm → page 114 In-situ thermal insulation DD HIT-HP MD-OT HIT-HP MDX-OT HIT-SP MDX-OT HIT-SP MD-OT Main slab...

 Open the catalog to page 9
HALFEN HIT Insulated Connection-10

HALFEN HIT INSULATED CONNECTION HIGH & SUPERIOR PERFORMANCE Material specification Tension bars Flash butt welded bar connection, consisting of a combination of two reinforcing steel bars B500B according to DIN 488 and a stainless bar steel of strength class S 690 Shear bars Stainless bar steel of strength B500NR or flash butt welded bars connection, consisting of a combination of stainless bar steel B500NR and reinforcing steel bars B500B Compression shear bearings High-performance mortar with increased compressive and tensile strength as well as optimized thermal conductivity Insulating material...

 Open the catalog to page 10
HALFEN HIT Insulated Connection-11

HALFEN HIT INSULATED CONNECTION HIGH & SUPERIOR PERFORMANCE CSB (C€ Balcony connection for cantilevered balcony slabs Transfers bending moments and shear forces Standard design: HIT-HP MV - High Performance with insulation thickness 80 mm HIT-SP MV - Superior Performance with insulation thickness 120 mm HIT-HP MV-ES - High Performance for element slabs HIT-SP MV-ES - Superior Performance for element slabs Application: Cantilevered balcony Available widths Content Type Page The basics on load bearing capacity HIT-HP MV, IIII SP MV 12 Product types HIT-HP MV, HIT-SP MV 13 Load bearing capacity...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.