Hadley-Group-UltraGrid-Brochure
16Pages

{{requestButtons}}

Catalog excerpts

Hadley-Group-UltraGrid-Brochure - 2

A unique ceiling grid system solution

Open the catalog to page 2
Hadley-Group-UltraGrid-Brochure - 3

The unique advantages of UltraGRID® 4 Slot Details, Angle &Trim 12 Product Ordering References 14 Utilising Hadley Group’s patented UltraSTEEL® process, Hadley UltraGRID® exposed ceiling grid systems offer distinct performance advantages over all other ceiling grid systems, underpinned by extensive technical and design support from Hadley Group’s in-house structural experts. Suitable for installation in most office, retail, showroom, public and private sector environments UltraGRID®systems can accommodate a variety of lay-in ceiling tiles.

Open the catalog to page 3
Hadley-Group-UltraGrid-Brochure - 4

The unique advantages of UltraGRID® The unique advantages of UltraGRID Setting UltraGRID® aside as unique are the numerous performance advantages delivered as a result of the UltraSTEEL® process, a technological breakthrough, which is added to UltraGRID®as part of the manufacturing process. The UltraSTEEL®process effectively doubles the thickness of the raw material, thereby optimising the performance of UltraGRID® ceiling systems in a number of ways; • Reduces the need to use heavier gauge materials thereby saving up to 20% on raw materials, increasing cost-effectiveness • Greater load...

Open the catalog to page 4
Hadley-Group-UltraGrid-Brochure - 6

FACE WIDTH COMPOSITION & MANUFACTURE Main and Cross Tee’s are cold rollformed from Hot Dipped Galvanised Steel utilising the patented UltraSTEEL™ process and finished with prepainted capping. In addition to the benefits of the UltraSTEEL™ process both Main and Cross Tee’s are double stitched for improved quality. A: Main Tee End Connector detail. B: Main Tee End Connection. End Connector detail. A: Main Tee DRAWING/PHOTOGRAPH KEY C: Cross Tee to Main TeeTee End Connection. B: Main Connection. D: Fire Expansion Joint. C: Cross Tee A: UltraGRID ™ detail. Main Tee End Connector to Main Tee...

Open the catalog to page 6
Hadley-Group-UltraGrid-Brochure - 7

Improved memory and spring tension characteristics Sections manufactured using the UltraSTEEL® process have a greater ability to return to their original form after loading. Plain Steel Plain Steel A comparison between two samples from the same original coil indicates a 31% reduction in permanent deformation. The UltraSTEEL® cross-section ensures that every screw is in contact with a material thickness greater that the nominal gauge of the steel, resulting in a significant increase in the torque required to strip-out the screw. Plain Steel Enhanced screw retention Screw Strip-Out Torque...

Open the catalog to page 7
Hadley-Group-UltraGrid-Brochure - 8

C eiling grid load carrying information Maximum Gross Ceiling Weight Once hanger spacings have been established calculate the maximum ceiling weight for the Main Tee from the graph, and the Cross Tee from the chart. The maximum gross ceiling weight allowable is the lower of the two values.

Open the catalog to page 8
Hadley-Group-UltraGrid-Brochure - 9

UltraGRID® 3824 Metric System MAIN TEE CROSS TEE CROSS TEE WALL ANGLE (A) Length(A) LENGTH (mm) (mm) MAIN TEE 3600 COMPONENT Cross Tee Cross Tee 38 Cross Tee Cross Tee 38 500 600 1000 CROSS TEE WALL ANGLE 1200 CROSS TEE CROSS TEE CROSS TEE CROSS TEE CROSS TEE CROSS TEE Wall24 Angle Shadow Angle SHADOW ANGLE WALL ANGLE SHADOW ANGLE Ceiling grid load carrying information Kg Per Box Metres. Per Box Ceiling grid load carrying information SHADOW ANGLE CROSS MAIN TEE Ceiling grid load carrying information TEECross Tee CROSS TEE Maximum Gross Ceiling Weight 0.6 metre centres Once hanger spacings...

Open the catalog to page 9
Hadley-Group-UltraGrid-Brochure - 10

UltraGRID® 3815 Imperial System SYSTEM MAIN TEE CROSS TEE CROSS TEE WALL ANGLE (A)MAIN TEE Length (A) LENGTH (Feet) (feet) COMPONENT 12 Cross Tee 11⁄2” Cross Tee 11⁄2” Cross Tee Cross Tee 19 CROSS TEE CROSS TEE CROSS TEE CROSS TEE 19 19 15 ⁄32” ⁄16” 32 Wall Angle Shadow Angle Ceiling grid load carrying information SHADOW ANGLE SHADOWANGLE WALL ANGLE lbs Per Box grid load carryingPer Box Feet. information Ceiling SHADOW ANGLE 2 CROSS TEE CROSS TEE CROSS TEE WALL ANGLE 4 Ceiling grid load carrying information Maximum Gross Ceiling Weight 2 feet centres graph, and the Cross Tee from the chart....

Open the catalog to page 10
Hadley-Group-UltraGrid-Brochure - 11

UltraGRID® 3824 Imperial System Component (A)Length (feet) Quantity* PerBox Wall Angle Ceiling grid load carrying information Maximum Gross Ceiling Weight Once hanger spacings have been established calculate the maximum ceiling weight for the Main Tee from the graph, and the Cross Tee from the chart. The maximum gross ceiling weight allowable is the lower of the two values. Ceiling grid load carrying information Maximum Gross Ceiling Weight Once hanger spacings have been established calculate the maximum ceiling weight for the Main Tee from the graph, and the Cross Tee from the chart. The...

Open the catalog to page 11
Hadley-Group-UltraGrid-Brochure - 12

UltraGRID UltraGRID ™ Slot Detail / Angle & Trim RID ™ UltraGRID ™ UltraGRID ™ GRID ™ ® 400mm Slot Detail ® etail Detail Slot Detail Slot UltraGRID400mm 400mm 500mm 400mm Slot Detail Detail 400mm 500mm

Open the catalog to page 12
Hadley-Group-UltraGrid-Brochure - 13

Recommended UltraGRID® Dimensions The recommended UltraGRID dimensions, in accordance with ASTM C635, have been stated below. Test procedures and deflection limits for a direct hung, light duty system have been used to declare recommended grid layouts relative to the metal grid profiles only. Capacities of tiles and ancillary components not supplied by Hadley Industries should be recommended by relevant suppliers. All testing has been carried out at Hadley Industries, research and product development department. This information herein is confidential and copyright companies can accept...

Open the catalog to page 13
Hadley-Group-UltraGrid-Brochure - 14

Product Ordering References Product Ordering References Example Main Tee 3824M100

Open the catalog to page 14
Hadley-Group-UltraGrid-Brochure - 15

8 Manufacturing Centres Worldwide 8 Manufacturing Centres Worldwide Worldwide supply Hadley Group’s heritage may be in the heart of the UK Midlands yet geography has never been a constraint to Customer Care At Hadley we have shaped our business around Today, with eight manufacturing centres serving contracts and licence agreements on five continents and in 36 countries, we are firmly ‘on the map’ - a truly international business, in every way with an unerring focus on practical ingenuity. adding value for our customers; understanding their diverse needs and, through local expertise, market...

Open the catalog to page 15

All HADLEY catalogs and technical brochures

  1. UltraSTEEL

    8 Pages

  2. Hi 30

    2 Pages

  3. UltraSTRUT?

    4 Pages

  4. UltraMEZZ®

    16 Pages

Archived catalogs

  1. UltraBEAM

    28 Pages

  2. COUNTRY-CLAD

    2 Pages

  3. UltraFENCE

    4 Pages

  4. Steel Framing

    24 Pages

  5. Purlings

    65 Pages

  6. UltraSHEET

    2 Pages

  7. UltraSTEEL

    4 Pages

  8. UltraBar

    4 Pages