DATA SHEET TNTplus® Vial Chemistries Hach TNTplus Vial Chemistries offer quality you expect from Hach that’s even easier to use and more accurate than ever. For a complete list of available parameters and USEPA acceptance status, please see page 2. Features and Benefits Reduce Errors with Bar-coded Vials Innovative Vial and Reagent Delivery A unique barcode label on each Hach TNTplus Vial Chemistry is automatically read by the spectrophotometer when used with Hach's DR spectrophotometers to identify the appropriate method and take the measurement. While increasing ease-of-use and speed of analysis, potential errors are significantly reduced. TNTplus vials use innovative DosiCaps that are easier to use than powder pillows or liquid reagents. There’s no risk of spillage, no safety risk, or risk of contamination with DosiCaps because the reagents are completely contained within the vial cap. The glassware used assures the best precision and the vials have a flat bottom so they can stand on their own. No Reagent Blank Necessary Even the Package is Useful The high quality of TNTplus vials, tight reagent production controls, 10-fold absorbance readings averaged for results determination, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money! Packages of TNTplus vials are color-coded for fast and easy parameter and range recognition for the exact test you need. Step-by-step illustrated test methods are printed on the box for quick reference. Simple instructions in multiple languages are included in each carton, facilitating use by a diverse labor force. New features have been added to the vial barcode, allowing the spectrophotometer to detect the reagent lot number and expiration date—notifying the user if reagents are expired. Using a DR3900 or DR6000 equipped with the RFID feature, an RFID* tag on the package triggers any required method calibration updates simply by placing the box adjacent to the instrument. *RFID technology currently available in US, Canada, Australia, and New Zealand only. Methods for EPA Compliance Monitoring Hach TNTplus Vial Chemistries for COD (Hach Method 8000), Free and Total Chlorine (SM 4500-Cl G), Chromium VI (SM 3500-Cr B, D), Iron (Hach Method 8008), Ortho- (EPA 365.1) and Total Phosphate (EPA 365.1, 365.3), Ammonia (EPA 350.1), and Nitrite (EPA 353.2) are equivalent to the respective method referenced in parentheses under 40 CFR 136.6 for compliance monitoring. Nitrate TNT835 and TNT836 are approved for drinking water monitoring under 40 CFR 141. As with any method used for compliance reporting, consult with your local regulatory authority. DW = drinking water WW = wastewater municipal PW = pure water / power IW = industrial water E = environmental C = collections FB = food and beverage
Open the catalog to page 1Specifications and Ordering Information* Chemical Method Shelf Life Storage (months) Temp(°C) Alkalinity, Total TNT867 Chlorine, Free and Total 0.05 to 2.00 Equivalent Phenanthroline Acid Persulfate Digestion 36 TNT880 Nitrogen, Simplified Total Kjeldahl 0 to 16 TNT843 Phosphate, Total* and Ortho, LR TNT844 Phosphate, Total* and Ortho, LR TNT845 Phosphate, Total* and Ortho, LR TNT846 Phosphate, Ortho only Ascorbic Acid Ascorbic Acid Ascorbic Acid Volatile Acids ^Requires digestion. fAs listed, test determines soluble metal. Order Metals Prep Set TNT 890 to determine total metal. *Add...
Open the catalog to page 2Metals Prep Set (used for Cu, Fe, Pb, Cd, & Ni digestion), 50 digestions Calcium Separation Set (used for Cadmium test), 24 separations Sample Blank Vials, 5 qty. Single Channel Pipet, 0.2 to 1.0 mL Single Channel Pipet, 1.0 to 5.0 mL Pipet Tips for BBP078, 100/pk Pipet Tips for BBP065, 75/pk One each of BBP078 and BBP065 and one box tips for each 9 vials x 13 mm + 2 vials x 20 mm (mono block), 115 Vac 21 vials x 13 mm + 4 vials x 20 mm (dual block), 115 Vac 15 vials x 13 mm + 15 vials x 13 mm (dual block), 115 Vac 12 vials x 13 mm + 8 vials x 20 mm (dual block), 115 Vac 9 vials x 13 mm + 2...
Open the catalog to page 3To complete your chemical analysis, choose from these instruments… DR 6000™ UV-Vis Laboratory Spectrophotometer (see Lit. #2797) With high speed wavelength scanning across the UV and Visible Spectrum, and over 250 pre-programmed testing methods, the DR6000™ is the industry’s most advanced lab spectrophotometer. Add in guided step-by-step procedures and integrated quality assurance software, and it makes sure you are ready to handle your comprehensive water testing needs. Available RFID* technology automatically updates the program calibration factors when you place a TNTplus box near the...
Open the catalog to page 4All HACH catalogs and technical brochures
-
HQ Series Portable Meters
4 Pages
-
DR300 Pocket Colorimeter
2 Pages
-
MP Meters
4 Pages
-
QbD 1200 TOC Analyzer
2 Pages
-
HQd Portable Meters
8 Pages
-
DR 3900? SPECTROPHOTOMETER
4 Pages
-
LG357
4 Pages
-
LG162 rev2
4 Pages
-
L2597 rev3
32 Pages
-
L2810
2 Pages
-
L2597 rev3
16 Pages
-
Evita Oxy Transmitter
4 Pages
-
sc200™ Universal Controller
8 Pages
-
DR/5000 Spectrophotometer
4 Pages
-
Pocket Colorimeter II
4 Pages
-
ph electrochemistry
13 Pages
-
l2596
4 Pages
-
l25592
4 Pages