Product catalog summary
Overview: The MET ONE HHPC series is a reliable and feature-rich handheld particle counter designed for cleanroom and indoor air quality (IAQ) monitoring. It offers models with two or six particle size channels, built-in relative humidity and temperature sensors, and an expandable memory option for up to 2000 data records.
Specifications: The HHPC series includes models with 6 or 2 size channels, capable of detecting particles as small as 0.3 μm. The flow rate is consistent at 0.1 CFM (2.83 LPM) across models. The devices are equipped with an isokinetic probe, high purity tubing, and a universal power supply. The HHPC-6 model features a graphic liquid crystal display with backlight, while the HHPC-2 has a simpler LCD display.
Data Management: When used with PortAll Version 2 software, the HHPC series can organize, archive, and graphically present particle count data, providing insights into contamination profiles and trends. The software also allows for scheduled sample collection.
Calibration and Support: The devices are calibrated using PSL particles in air, traceable to NIST standards. Global calibration and service centers are available in over 80 countries, ensuring comprehensive support for the HHPC series.
Environmental and Power Specifications: The operating temperature range is 10°C to 40°C, with storage capabilities from -10°C to 50°C. The devices operate on a rechargeable NiMH battery with an 8-hour continuous runtime and a 2-hour recharge time.
Accessories: Included accessories are a certificate of calibration, utility software package, various adapters and cables, and a power supply. Optional accessories include a zero count filter, extension cable, carrying case, and portable serial printer.
Contact Information: For pricing, technical support, and ordering, contact Hach Company through their various regional offices.
See more

Catalog excerpts

MET ONE HHPC-2 and HHPC-6, Handheld Particle Counter-1

DATA SHEET MET ONE HHPC-2 and HHPC-6 Handheld Particle Counter The world’s most popular handheld particle counter When it comes to tracking down particle problems, the reliability and rich feature set of the MET ONE HHPC series makes these handhelds clear winners amongst cleanroom and indoor air quality (IAQ) monitoring professionals. Available with either two or six particle size channels, built-in relative humidity and temperature sensors and an expandable memory option providing up to 2000 data records, the HHPC handheld series has your most comprehensive monitoring applications covered. Features When combined with PortAll Version 2 software, the full power of the HHPC series is unleashed. Particle count data can be organized, archived and graphically presented to provide critical insight into contamination profiles and trends. This easy-to-use software can also be used to schedule the collection of samples, allowing monitoring to run unattended. Above all, with global calibration and service centers located in over 80 countries you can be assured that your investment in the HHPC series will be fully supported. HHPC-6 (0.3 µm) HHPC-6 (0.5 µm) HHPC-2 (0.3 µm) HHPC-2 (0.5 µm) Number of Size Channels 6 6 2 2 Number of Records (memory) 500 500 100 100 Extended Memory Option • • Temperature and RH Probe • • Isokinetic Probe • • • • RJ45 to DB9 Converter • • • • High Purity Tubing • • • • Universal Power Supply • • • • Network Cable • • • • Channels 0.3 μm 0.5 μm 0.3 μm 0.5 μm 0.5 μm 0.7 μm 0.5 μm 5.0 μm 0.7 μm 1.0 μm 1.0 μm 2.0 μm 2.0 μm 5.0 μm 5.0 μm 10.0 μm Sensitivity 0.3 μm 0.5 μm 0.3 μm 0.5 μm Flow 0.1 CFM (2.83 LPM) 0.1 CFM (2.83 LPM) 0.1 CFM (2.83 LPM) 0.1 CFM (2.83 LPM) Key Specifications ®

 Open the catalog to page 1
MET ONE HHPC-2 and HHPC-6, Handheld Particle Counter-2

Specifications 2 Size Channels HHPC-2 Standard 0.3 and 0.5 μm or 0.5 and 5.0 μm IAQ 0.3 and 1.0 μm Custom 0.3 to 10 µm or 0.5 to 15 µm or 1.0 to 20 µm 6 Size Channels HHPC-6 Standard 0.3, 0.5, 0.7, 1.0, 2.0, 5.0 µm IAQ 0.5, 0.7, 1.0, 2.0, 5.0, 10.0 µm Custom 0.3 to 10 µm, 0.5 to 15 µm or 1.0 to 20 µm Sample Volume Options HHPC-2 0.01 ft3 00:06 Minutes:Seconds (MM:SS) 28.3 L3 10:00 Minutes:Seconds (MM:SS) 10.0 L3 03:53 Minutes:Seconds (MM:SS) 2.83 L3 01:00 Minutes:Seconds (MM:SS) HHPC-6 1.0 L3 21 seconds 0.01 ft3 6 seconds 10.0 L3 3.53 minutes 1.0 ft3 10 minutes 2.83 L3 60 seconds 0.10 ft3 60...

 Open the catalog to page 2

All HACH catalogs and technical brochures

  1. MP Meters

    4  Pages

  2. LG357

    4  Pages

  3. LG162 rev2

    4  Pages

  4. L2597 rev3

    32  Pages

  5. L2810

    2  Pages

  6. L2597 rev3

    16  Pages

  7. l2596

    4  Pages

  8. l25592

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.