Catalog excerpts
AL FIXING WITHOUT MECHANIC Solutions for standard or seismic joints VEDAFEU SV© BLANKET STRENGTHS Tested and certified for horizontal and vertical applications. Horizontal configuration Vertical configuration Initial joint With compression Initial joint With movement EXPANSION MOVEMENTS Tested and certified up to +50% expansion. EASY to handle and to install. SAFE for the health and the environment. APPLICATIONS Hospitals, industrial buildings, offices, housing, hotels, malls, carparks, schools, train stations, airports, stadiums, etc.. *Maximum joint width:
Open the catalog to page 1OFFICIAL CLASSIFICATION Classification report n° EFR-18-000352 dated 11/06/2019 EI 240 – H – M50 – B – W 40 to 200 EI 240 – V – M50 – B – W 40 to 200 Other classification reports upon request. Refer to classification report or ETA for types and thicknesses of supports validated. VEDAFEU SV© Blankets according to initial joint width Initial joint width [mm] Maximum validated gap = initial gap + M50 (50% of initial joint width). *For intermediate gaps, the use of a smaller reference will result in a decrease in the movement capacity. Installation instructions for joint widths from 40 to...
Open the catalog to page 2VEDAFEU SV® PROPERTIESVEDAFEU SV© firestop blankets COMPRESSIBILITY tests VEDAFEU SV© THERMAL Properties In accordance with the Thermal Regulation RT 2012 Results of test reports n° RA.20.47.GA-SV dated 19/11/2020 (available upon request). Results of test report n° EFR-18-000352 dated 11/06/2019 (available upon request). VEDAFEU SV© ACOUSTIC Properties In accordance with the NRA 2012 (acoustic regulations) Sound attenuation (dB) depending on diameter of rope (mm) Results of test report BEB2-K.6046 dated 29/10/2020 (available upon request).
Open the catalog to page 3All GV2 VEDA FRANCE catalogs and technical brochures
-
Control joints - JF 800
1 Pages
-
Control joints - JF 600
1 Pages
-
Control joints - JF 1700
1 Pages
-
Car park joint - JDH 5.31
1 Pages
-
Antislip adhesive tape
2 Pages
-
Stair nosing - Series NDM VD
1 Pages
-
Car park joint - JDH 5.35
1 Pages
-
THE RANGE
64 Pages
-
JDH 6.11
1 Pages
-
VEDAFEU N FIRESTOPS BLANKETS
2 Pages
-
VEDAFEU M FIRESTOPS BLANKETS
3 Pages
-
VEDAFEU C FIRESTOPS ROPES
6 Pages
-
COMPRESSION PROFILES CP
1 Pages
-
COMPRESSION PROFILES - PSR
1 Pages
-
JOINT COVER - CJP
2 Pages
-
Joint covers
2 Pages
-
Control Joints - JF Deco
1 Pages
-
Control joints - JF 1600
1 Pages