VEDAFEU C ROPES The most extensive range in firestop systems FIRESTOP 4H EI 240 tested CERTIFIED VEDAFEU C© ROPE STRENGTHS Horizontal configuration CONFIGURATIONS Tested and certified for horizontal and vertical applications. EXPOSURE Tested and certified not exposed or exposed to fire. Not exposed to fire Exposed to fire Tested and certified up to -85% compression. Initial joint With compression EXPANSION MOVEMENTS Tested and certified up to +20% expansion. Initial joint EASY to handle and to install. SAFE for the health and the environment. APPLICATIONS Hospitals, industrial buildings, offices, housing, hotels, malls, carparks, schools, train stations, airports, stadiums, etc.

Open the catalog to page 1
VEDAFEU C FIRESTOPS ROPES - 2

15 OFFICIAL CLASSIFICATION Classification report n° EFR 20-002698 dated 01/09/2020 EI 240 – H – M20 – B – W 10 to 120 EI 240 – V – M20 – B – W 10 to 120 Other classification reports upon request: with sealant, joint cover, EPDM membrane, head-of-wall, exposed to fire... Refer to classification report or ETA for types and thicknesses of supports validated. European Technical Assessment: ETA 22/0321. Declaration of performance: N° C-22/0321 VEDAFEU C© Ropes according to initial joint width Initial joint width [mm] Reference* VEDAFEU C© ø rope [mm] *Minimum compression of 33% (except for 10mm...

Open the catalog to page 2
VEDAFEU C FIRESTOPS ROPES - 3

CERTIFIED CONFIGURATIONS CERTIFIED CERTIFIED WITH joint cover NO sealant NO sealant NO joint cover CERTIFIED WITH sealant NO joint cover Floor, wall and ceiling expansion joints Application on floor and wall with junctions. © All rights reserved - Non contractual drawings - 06/2023 WITH waterproofing membrane

Open the catalog to page 3
VEDAFEU C FIRESTOPS ROPES - 4

Head-of-wall The use of a single Firestop VEDAFEU C© rope at the centre of the joint in a head-of-wall configuration has been tested and certified by Efectis France, CSTB and CERIB. The last configuration validated offer a performance whatever the fire side with a single Firestop VEDAFEU C© rope with a compression rate of 33% in the middle of the masonry without adhesive. Other results are available on page 18. 'Minimum compression of 33% (except for 10mm gaps : 17%). EASY AND FAST INSTALLATION ► Can be done even if the access is only possible on one side of the wall. ► Without adhesive...

Open the catalog to page 4
VEDAFEU C FIRESTOPS ROPES - 5

CERTIFIED INSTALLATION WITH JOINT COVER (Optional) VEDAFEU C© with special head-of-wall joint cover. FIRE EXPECTED FROM BOTH SIDES Performance Other applications Windows and doors frames, bearing protection, facade panels, tunnels ...

Open the catalog to page 5
VEDAFEU C FIRESTOPS ROPES - 6

VEDAFEU C© PROPERTIES © VEDAFEU C firestop rope COMPRESSIBILITY tests Ref. Results of test report n° MRF 19 26080307 dated 14/05/2019 (available upon request). VEDAFEU C© firestop rope SHEARING tests Reference VEDAFEU C© Results of test report n° EEM 20 26087588 dated 26/10/2020 (available upon request). VEDAFEU C© AIR and SMOKE tightness Nominal pressure (Pa) Results of test report n° 16-26061937 dated 22/03/2016 (available upon request). VEDAFEU C© THERMAL Properties In accordance with the Thermal Regulation RT 2012