Interior Insulation
13Pages

{{requestButtons}}

Catalog excerpts

Interior Insulation - 1

Interior Insulation of Exterior Walls GUTEX Thermoroom®

Open the catalog to page 1
Interior Insulation - 2

Table of Contents A Performance-Tested Insulation System Important Considerations NEW: GUTEX Flankendämmkeil Planning the Insulation of Corner Junctions Installing the Insulation Boards Plaster Work Installing over Wood Structures Installation Details

Open the catalog to page 2
Interior Insulation - 3

Scientifically Tested GUTEX Thermoroom Interior Insulation System GUTEX Thermoroom possesses all the qualities necessary for optimum interior insulation: Introduction Interior insulation is a consideration particularly for buildings for which exterior insulation is not possible or ill advised due to the historical significance or listing of the building. ✓ Insulation against the cold in winter Thanks to its minimum thermal conductivity (λ=0.038 W/mK), it creates warmer wall and ceiling surfaces for improved indoor comfort. The advantages offered by interior insulation include the absence of...

Open the catalog to page 3
Interior Insulation - 4

To ensure the building is not damaged by the retrofitting of outer walls with interior insulation, the existing situation and status of the building must be evaluated prior to beginning with the planning. Key factors are diffusion permeability, capillary action and the insulation performance of the wall elements (U-value). Suitable action to prevent the outer wall from becoming damp due to driving rain and rising damp must be taken prior to beginning with refurbishment work. Diffusion permeability GUTEX Thermorooms' diffusion capacity makes it an ideal insulation for interior use. It...

Open the catalog to page 4
Interior Insulation - 5

NEW: GUTEX Flankendämmkeil An example The following simulated thermal images show building sections both with and without the corner insulation wedges. By adhering to several important principles, mould and mildew, which occur with the presence of high humidity or low temperatures, can be easily avoided. Corner junctions of exterior walls with ceilings and interior walls In Germany, the DIN 4108-2 standard for the insulation of buildings specifies interior surface temperatures of greater than 12.6° C to avoid condensation and thereby prevent mould and mildew. To maintain 12.6° C across all...

Open the catalog to page 5
Interior Insulation - 6

Planning the Insulation of Corner Junctions When is it necessary to insulate corner Detail Innendämmung Anschluss AW-IW junctions? Situation 2: Junction between masonry interior walls and masonry exterior walls, with timber stud The following tables will help you determine if it is necessary to insulate corner junctions. Based on the building substance of the structures and their respective thermal conductivity properties, the approximate U-values of walls can be determined using the tables below. Use the U-values for the exterior and interior walls in the tables at the bottom of the page...

Open the catalog to page 6
Interior Insulation - 7

Planning the Insulation of Corner Junctions nendämmung AW-IW Detail Innendämmung Exterior wall & concrete ceiling junctions Example Anschluss AW-IW Using the data for interior and exterior masonry walls The required thermal conductivity values are available in Table 1. Details about the concrete ceiling used in the table below: • Thermal conductivity (λ-value) of concrete is 2.5 W/mK • Reinforced with 2 % steel; 16 cm thick • 10-mm edge insulation strips, thermal conductivity (λ) is 0.040 W/mK • 15-mm floor insulation; thermal conductivity (λ) is 0.040 W/mK Original exterior wall: 24-cm...

Open the catalog to page 7
Interior Insulation - 8

Installing the Insulation Boards 4.  Installing the boards Install the GUTEX Thermoroom so the full area of its rear side adheres to the suitably prepared substrate. Make sure the joints and boards are vertically and horizontally plumb. The offset of the boards must be min. 20 cm. Use of additional mechanical fasteners is unnecessary when using GUTEX Thermoroom. Guidelines for installing the insulation boards 1. Proper preparation of the substrate Check the existing substrate for soundness, removing loose wall covering and repairing crumbling plaster, etc. Apply a primer to sandy surfaces...

Open the catalog to page 8
Interior Insulation - 9

Existing exterior wall with any U-value, sd-value of maximum 30 m, high to extremely high capillary action in the outer 2 - 4 cm of the walls’ interior. Existing exterior wall with any U-value, sd-value of maximum 30 m, low to moderate capillary action in the outer 2 - 4 cm of the wall’s interior. Option 1: Mineral plaster Base coat Base coat Apply GUTEX Klebe- und Spachtelputz mortar to the newly clad walls to create a coat of at least 4 mm. Embed the reinforcement mesh in the outer third of the coat. Apply GUTEX Klebe- und Spachtelputz mortar to create a coat of at least 4 mm. Embed the...

Open the catalog to page 9
Interior Insulation - 10

Installing over Wood Structures When installing the wood fibreboards over wood structural elements, the element’s substrates must be at least 12-mm thick and consist of composite wood sheathing or solid wood. Suitable common wood screws or staples, the latter with a back width of 10 mm, may be used. The offset of the boards must be min. 20 cm. The penetration depth of the fixings must 50-100at least 12 mm. be mm The following figures provide information about the quantity of 50-100 mm fasteners required. GUTEX Thermoroom 40 – 100 mm 6 screws with 60-mm ∅ plastic discs per fibreboard Fixing...

Open the catalog to page 10
Interior Insulation - 11

Installation Details Detail Thermoroom Anschluss Fensterlaibung Original exterior render Original exterior wall Window V-groove GUTEX Fugendichtband (adhesive sealing strip)* GUTEX Thermoroom, min. 20 mm Original interior plaster finish GUTEX Thermoroom GUTEX Putzsystem (interior plaster) GUTEX Klebe- und Spachtelputz Hinweis: Dieses Detail ist ein allgemeiner Planungsvorschlag, welcher schematisch die Ausführung eines WDVS darstellt. Anwendbarkeit und Vollständigkeit sind vom Verarbeiter/Kunden beim jeweiligen Bauvorhaben eigenverantwortlich zu prüfen. Angrenzende Gewerke sind nur...

Open the catalog to page 11
Interior Insulation - 12

Pleasant indoor environment GUTEX wood fibre insulation boards are vapour permeable (μ = 3), regulating the living environment with their ability to absorb and release up to 15 % of their weight in moisture without the loss of their insulation capacity. Acoustic insulation The open-pore structure of GUTEX wood fibreboards and their high absorption volume contribute to their ability to deliver superb soundproofing against airborne and impact noise. Fire protection GUTEX wood fibre insulation boards easily comply with fire protection regulations. Various individual certificates of approval...

Open the catalog to page 12

All GUTEX catalogs and technical brochures

  1. Construction

    48 Pages

  2. Thermoroom

    1 Pages