Catalog excerpts
Construction Recommendations Construction examples for roof, wall, floor and ceiling
Open the catalog to page 1Contents General information 1. Roof 1.1 Full rafter insulation, new build 1.2 On-roof insulation, new build/reconstruction 1.3 Common rafter insulation reconstruction, from inside 1.4 Common rafter insulation reconstruction, from outside 1.4.1 Common rafter insulation reconstruction, from outside/interior panelling PB 1.4.2 Common rafter insulation reconstruction, from outside/interior panelling HWL 1.4.3 Common rafter insulation reconstruction, from outside/interior panelling for profiled wood formwork 2. Wall 2.1 Timber frame construction 2.2 Brickwork reconstruction, from outside 2.3...
Open the catalog to page 2The brochure below entitled "Construction Recommendations" provides a summary of the design examples for roof, wall, floor and ceiling, with the relevant structural values for the protection against cold winter temperatures, hot summer temperatures, noise and fire.All constructions are calculated in accordance with DIN 4108 and hence tested for diffusion, moisture and condensate. The result is a comprehensive work of reference, which considerably simplifies component planning. To create a failure-free construction, the manufacturer's data and/or the installation instructions for all...
Open the catalog to page 3JThe requirements and recommendations are defined in DIN 4109. Components are supposed to dampen and/ or minimise the noise outside and inside the building. For noise protection, a distinction is drawn between airborne noise and impact noise. Airborne noise protection is relevant for wall and roof components, impact noise protection for floor and ceiling constructions. Semi-detached houses and terraced houses Recommendations for im- Partition walls proved noise protection P.4 GUTEX Construction Recommendations V-
Open the catalog to page 4Fire protection Environmental compatibility GUTEX understands fire safety as protection for people and animals against fire. Fire safety, however, also means minimising the resultant damage. The requirements for building fire safety are regulated by the countries concerned. There are two distinctly different requirements. One is the building material class or its fire behaviour and the other is the fire resistance class of a component. Building material classes or fire behaviour fall into classes A = "nonflammable" to F = "highly-flammable". For the construction industry, however, the...
Open the catalog to page 51.1 Full rafter insulation new build - Tile battens - Tile battens - Counter battens - Counter battens - GUTEX Multiplex-top® - GUTEX Ultratherm® - GUTEX Thermofibre /GUTEX Thermoflex between the rafters - GUTEX Thermofibre®/GUTEX Thermoflex® between the rafters - Vapour barrier/air seal - Vapour barrier/air seal Noise insulation value RW, R (dB) 2) GUTEX Thermofibre®/ Thermoflex® (mm) GUTEX Thermofibre®/ Thermoflex® (mm) 1) Calculation with 10 % wood content 2) The noise levels refer to a construction with GUTEX Thermoflex, a roof covering with concrete roofing tiles and double-threaded...
Open the catalog to page 61.2 On-roof insulation, new build/reconstruction - Tile battens - Tile battens - Counter battens - Counter battens - GUTEX Multiplex-top/GUTEX Ultratherm - GUTEX Multiplex-top®/GUTEX Ultratherm® - GUTEX Thermosafe-homogen - GUTEX Thermofibre® between double I-joists - Vapour barrier/air seal - Vapour barrier/air seal - Exposed rafters - Exposed rafters GUTEX Multiplextop Noise insulation value RW, R (dB)2) GUTEX U-factor 1) Thermofibre® (W/m2K) (mm) GUTEX Ultratherm® GUTEX Multiplextop® 1) Calculation with 10 % wood content 2) The noise levels refer to a construction with GUTEX Thermoflex,...
Open the catalog to page 71.3.1 Common rafter insulation Structure: - Existing tile battens - Existing counter battens - Existing formwork with bitumen sheeting 26 mm - GUTEX Thermofibre®/GUTEX Thermoflex® between the rafters - GUTEX Multitherm® with groove and spring - Vapour barrier/air seal, moisture variable - Battens - Facing 1.3.2 Common rafter insulation Structure: - Existing tile battens - Battens on rafters - GUTEX Multiplex-top® 22 mm between the rafters - GUTEX Thermofibre®/GUTEX Thermoflex® between the rafters - OSB board 15 mm - GUTEX Thermoroom® - Loam rendering layer 15 mm 1) Calculation with 10 %...
Open the catalog to page 81.3 Reconstruction, from inside/ 1.4 Reconstruction, from outside 1.4 Reconstruction, from outside Important information: GUTEX systematic roof reconstruction The following reconstruction variants from outside can be executed only using the membranes from the following GUTEX system partners: • Proclima, membranes Solitex UD, Solitex UD connect (0,02*) and DASAPLANO 0,01 connect (0,01*) • Ampack, membrane Ampack Ampatex LDA 0,02 plus (0,02*) 1.3.3 Common rafer insulation Structure: • Isocell, membranes OMEGA MONO 200 (0,15*) and OMEGA LIGHT (0,02*) - Existing tile battens - Battens on...
Open the catalog to page 9Structure: -Tile battens - Counter battens - GUTEX Ultratherm® -Air-tight membrane*' in accordance with GUTEX system partner - Mineral wool 035 between the rafters - Existing battens -PB/PF 12.5 mm I) Calculation with 10 % wood content 2) Values as per 'Informationsdienst Holz”. series 3. part 3. sequence 4. RA , = calculated value, mcl. allowance 3) When using GUTEX Thermofibre, air-tight interior panelling must be produced ‘Note: With this construction, the sd-value (or the air-tight membrane must not exceed 0.03m. “In these constructions, additional measures, for example insertion of a...
Open the catalog to page 101.4.1 Reconstruction, from outside 1.4.1.3 Interior panelling, plasterboard Structure: 1.4.1.4 Internal panelling, plasterboard Structure: - Tile battens - Counter battens - GUTEX Multiplex-top®/ Ultratherm® - Air-tight membrane in accordance with GUTEX system partner - GUTEX Thermoflex® between the rafters - Existing mineral wool with aluminium lining - Existing battens - PB/PF 12.5 mm - Tile battens - Counter battens - GUTEX Ultratherm® - Air-tight membrane in accordance with GUTEX system partner - GUTEX Thermoflex® between the rafters - Existing mineral wool with aluminium lining -...
Open the catalog to page 11All GUTEX catalogs and technical brochures
-
Interior Insulation
13 Pages
-
External Thermal Insulation
28 Pages
-
Energy Refurbishment
18 Pages
-
Product Application
24 Pages
-
Thermowall/-gf
2 Pages
-
Thermoroom
1 Pages
-
Multiplex-top
3 Pages
-
GUTEX Price List 2013
16 Pages
-
GUTEX Thermofibre®
4 Pages
-
GUTEX Implio®
4 Pages
-
GUTEX Thermowall® ETICS
4 Pages