TeboPin Select
2Pages

{{requestButtons}}

Catalog excerpts

TeboPin Select - 1

DESCR IPTION Base board: Maritime Pine throughout Plywood Faces (IAW EN 635-3): I++ / II Face side I++ All applications where the natural aesthetic of the wood is very important and where the reverse side may remain occasionally or partly visible. Joinery works, shelving, DIY, internal fittings, timber framed constructions. Tight without knots with wooden patches (maxi 1/m² = 3 per sheet) Tight with sound knots and wooden patches. Occasional synthetic repairs. Finishing: sanded 2 sides Average density (IAW EN 323): 580 kg/m3 (+/- 10%) Bonding (IAW EN 314-2): class 3 Service (IAW EN 636): class 3 exterior conditions Formaldehyde release classification (IAW EN 13986): E1 Content of Pentachlorophenol (IAW EN 13986): PCP ≈ 0 ppm Sizes, number of plies & packaging Number of plies Other sizes & thicknesses: on request Preservative treatments, fungicide & Insecticide, antitermite: optional on request Cutting & TG processing: optional on request Flat, on intermediate bearers, in an enclosed dry and ventilated building, clear of the ground. As far as storage on site is concerned, provision should be made to cover the panels with an opaque waterproof sheeting with the underside of the stacks clear of the ground. Compliance with standard practice, with regulations and with health and safety rules should be maintained at all times. Cutting and machining in the workshop possible except laser technology. PRODUCTION SITES Production on Thébault’s sites in France FURTHER PROCESSING & INSTALLATION TeboPin Clear

Open the catalog to page 1
TeboPin Select - 2

TECHNICAL PROPERTIES Characteristic values (MPA) IAW EN 789 - 1058 for structural calculations IAW Eurocodes 10 Available on DOP Strength in: Tension (ft), Compression (fc), Panel shear (fv) and Planar shear(fr) Modulus of elasticity in: Tension (Et), Compression (Ec), Panel shear (Gv) and planar shear (Gr) Others characteristic values Uses Use in structural applications (IAW EN 13986, EN 636-3, EN 636-2, EN 636-1) Suitable for use as structural element in exterior conditions (service class 3), humid conditions (service class 2) and interior conditions (service class 1) Bending radius (mm)...

Open the catalog to page 2

All Groupe THEBAULT catalogs and technical brochures

  1. TeboPin III

    2 Pages

  2. TeboWall

    2 Pages

  3. TeboRoof

    2 Pages

  4. TeboPin Star

    2 Pages

  5. TeboFlam

    3 Pages

  6. TeboProfil

    2 Pages

  7. TeboStile

    2 Pages

  8. TeboGarant

    2 Pages

  9. TeboMarine

    2 Pages