TeboPin Select
1 /2Pages

TeboPin Select

TeboPin Select
1 /2Pages

Catalog excerpts

TeboPin Select-1

All applications where the natural aesthetic of the wood is important and where the reverse side remains invisible. Joinery works, internal & external fittings, DIY, playgrounds, apparent roof underlays, wall linings, timber framed constructions. High class packing. Tight without knots with wooden patches (maxi 5/m²) Admitting open defects Finishing: sanded 2 sides Average density (IAW EN 323): 580 kg/m3 (+/- 10%) Bonding (IAW EN 314-2): class 3 Service (IAW EN 636): class 3 exterior conditions Formaldehyde release classification (IAW EN 13986): E1 Content of Pentachlorophenol (IAW EN 13986): PCP ≈ 0 ppm Sizes, number of plies & packaging Thicknesses (mm) 7 ©Eemporte-piece agency Other sizes & thicknesses: on request Preservative treatments, fungicide & Insecticide, antitermite: optional on request Cutting & TG processing: optional on request Flat, on intermediate bearers, in an enclosed dry and ventilated building, clear of the ground. As far as storage on site is concerned, provision should be made to cover the panels with an opaque waterproof sheeting with the underside of the stacks clear of the ground. FURTHER PROCESSING & INSTALLATION Compliance with standard practice, with regulations and with health and safety rules should be maintained at all times. Cutting and machining in the workshop possible except laser technology. PRODUCTION SITES Production on Thébault’s sites in France DESCR IPTION Base board: Maritime Pine throughout Plywood Faces (IAW EN 635-3): I / II TeboPin Selec

 Open the catalog to page 1
TeboPin Select-2

TECHNICAL PROPERTIES Characteristic values (MPA) IAW EN 789 - 1058 for structural calculations IAW Eurocodes 10 Available on DOP Strength in: Tension (ft), Compression (fc), Panel shear (fv) and Planar shear(fr) Modulus of elasticity in: Tension (Et), Compression (Ec), Panel shear (Gv) and planar shear (Gr) Others characteristic values Uses Use in structural applications (IAW EN 13986, EN 636-3, EN 636-2, EN 636-1) Suitable for use as structural element in exterior conditions (service class 3), humid conditions (service class 2) and interior conditions (service class 1) Bending radius (mm) Thickness...

 Open the catalog to page 2

All Groupe THEBAULT catalogs and technical brochures

  1. TeboPin III

    2  Pages

  2. Tebo Pin Flam

    3  Pages

  3. TeboWall

    2  Pages

  4. TeboRoof

    2  Pages

  5. TeboPin Star

    2  Pages

  6. TeboPin Elite

    2  Pages

  7. TeboPin Clear

    2  Pages

  8. TeboFlam

    3  Pages

  9. TeboProfil

    2  Pages

  10. TeboStile

    2  Pages

  11. TeboGarant

    2  Pages

  12. TeboMarine

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.