TeboMarine
2Pages

{{requestButtons}}

Catalog excerpts

TeboMarine - 1

Faces (IAW EN 635-2): II / III Finishing: sanded 2 sides Joinery works, internal fittings in boat building. Constructions in exposed exterior environments. Use in load bearing applications. Average density (IAW EN 323): 500 kg/m3 (+/- 10%) Bonding (IAW EN 314-2): class 3 Service (IAW EN 636): class 3 exterior conditions Formaldehyde release classification (IAW EN 13986): E1 Content of Pentachlorophenol (IAW EN 13986): PCP ≈ 0 ppm Sizes, number of plies & packaging Thicknesses (mm) 40 (17) Other sizes & thicknesses: on request OPTIONS TeboMarine as a structural component in flatroofing Preservative treatments, fungicide & Insecticide, antitermite: optional on request Cutting & TG processing: optional on request Flat, on intermediate bearers, in an enclosed dry and ventilated building, clear of the ground. As far as storage on site is concerned, provision should be made to cover the panels with an opaque waterproof sheeting with the underside of the stacks clear of the ground. FURTHER PROCESSING & INSTALLATION Compliance with standard practice, with regulations and with health and safety rules should be maintained at all times. Cutting and machining in the workshop possible except laser technology. Groupe THEBAULT 47, rue des Fontenelles - 79 460 MAGNE - France Tél : +33 (0)5 49 35 70 20 info@groupe-thebault.com PRODUCTION SITES Production on Thébault’s sites in France TeboMarine in facade construction Base board: Okoume throughout Plywood Manufacture: in accordance with the requirements BS 1088-1: 2003 and BS 1088-2: 2003, with certificate of conformity n° CC 03/13/1917/GB issued by an independent and notified body: FCBA - 10, avenue de Saint-Mandé 75012 Paris - France DESCR IPTION

Open the catalog to page 1
TeboMarine - 2

TECHNICAL PROPERTIES Characteristic values (MPA) IAW EN 789 - 1058 for structural calculations IAW Eurocodes 4 Modulus of elasticity (Em) Bending strength (fm) Available on DOP Strength in: Tension (ft), Compression (fc), Panel shear (fv) and Planar shear(fr) Modulus of elasticity in: Tension (Et), Compression (Ec), Panel shear (Gv) and planar shear (Gr) Others characteristic values Uses Use in structural applications (IAW EN 13986, EN 636-3, EN 636-2, EN 636-1) Suitable for use as structural element in exterior conditions (service class 3), humid conditions (service class 2) and interior...

Open the catalog to page 2

All Groupe THEBAULT catalogs and technical brochures

  1. TeboPin III

    2 Pages

  2. TeboWall

    2 Pages

  3. TeboRoof

    2 Pages

  4. TeboPin Star

    2 Pages

  5. TeboFlam

    3 Pages

  6. TeboProfil

    2 Pages

  7. TeboStile

    2 Pages

  8. TeboGarant

    2 Pages