Product Overview: TeboFloor II/III is designed for flooring and roofing applications in traditional timber-framed constructions. It features a sanded finish on one side and tongue & groove edge machining. The base board is made from Maritime Pine throughout plywood.
Technical Specifications:
  • Average Density: 580 kg/m3 (±10%)
  • Bonding: Class 3 (IAW EN 314-2)
  • Service Class: 1-3 (interior, humid, and exterior conditions) IAW EN 636
  • Formaldehyde Release: E1 (IAW EN 13986)
  • Pentachlorophenol Content: ≈ 0 ppm
Sizes and Packaging: Available in various thicknesses (12-30 mm) and sizes, with specific packaging quantities. Custom sizes and thicknesses are available upon request.
Options: Preservative treatments, fungicide, insecticide, and antitermite options are available on request. Cutting and TG processing are also optional.
Storage Recommendations: Store flat on intermediate bearers in a dry, ventilated building, clear of the ground. On-site storage should include opaque waterproof sheeting.
Processing and Installation: Follow standard practices, regulations, and health and safety rules. Workshop cutting and machining are possible, excluding laser technology.
Technical Properties: Characteristic values for modulus of elasticity and bending strength are provided for structural calculations. Additional strength and elasticity values are available in the Declaration of Performance (DoP).
Sizing and Span Tables: Maximum permissible spans for flooring and roofing are provided, with specific use categories and service classes.
Technical Suitability and Certification: The product holds various quality marks and certifications, including CE Marking and Ecocertification. It is suitable for structural applications in different environmental conditions.
Additional Properties:
  • Sound Absorption: Related to surface mass, with specific coefficients for different frequency ranges.
  • Thermal Conductivity: λ = 0.13 (IAW EN 13986)
  • Vapour Permeability: Wet cup 44 μ, Dry cup 187 μ
  • Reaction to Fire: Classified based on thickness and installation conditions.
See more

Catalog excerpts

TeboFloor II / III-1

DESCR IPTION Base board: Maritime Pine throughout Plywood Faces (IAW EN 635-3): II / III Face side II Flooring and roofing applications in traditional timber framed constructions. Tight with sound knots and wooden patches. Occasional synthetic repairs. Admitting open defects Finishing: sanded 1 side Edge machining: with tongue & groove Average density (IAW EN 323): 580 kg/m3 (+/- 10%) Bonding (IAW EN 314-2): class 3 Service (IAW EN 636): class 1-2-3 (interior, humid and exterior conditions) - flooring & roofing IAW EN 12871 Formaldehyde release classification (IAW EN 13986): E1 Content of Pentachlorophenol (IAW EN 13986): PCP ≈ 0 ppm Sizes, number of plies & packaging Packing *12 mm only on roof Other sizes & thicknesses: on request Preservative treatments, fungicide & Insecticide, antitermite: optional on request Cutting & TG processing: optional on request Flat, on intermediate bearers, in an enclosed dry and ventilated building, clear of the ground. As far as storage on site is concerned, provision should be made to cover the panels with an opaque waterproof sheeting with the underside of the stacks clear of the ground. Compliance with standard practice, with regulations and with health and safety rules should be maintained at all times. Cutting and machining in the workshop possible except laser technology. PRODUCTION SITES Production on Thébault’s sites in France FURTHER PROCESSING & INSTALLATION Groupe THEBAULT 47, rue des Fontenelles - 79 460 MAGNE - France Tél : +33 (0)5 49 35 70 20 [email protected]

 Open the catalog to page 1
TeboFloor II / III-2

TeboFloor II / III TECHNICAL PROPERTIES Characteristic values (MPA) IAW EN 789 - 1058 for structural calculations IAW Eurocodes 12* Others characteristic values Available on DOP : Strength in: Tension (ft), Compression (fc), Panel shear (fv) and Planar shear(fr) Modulus of elasticity in: Tension (Et), Compression (Ec), Panel shear (Gv) and planar shear (Gr) Uses Use in structural applications (IAW EN 13986, IAW EN 12871, 636-3, EN 636-2, EN 636-1) Suitable for use as structural element in exterior conditions (service class 3), humid conditions (service class 2) and interior conditions (service...

 Open the catalog to page 2
TeboFloor II / III-3

Sound absorption coefficient Reaction to fire Frequency range End use condition In reference to table 8 of EN 13986 - 2004+A1:2015 Minimum thickness Class excluding floorings Class floorings Without an air gap behind the panel With a closed or an open air gap not more than 22 mm behind the woodbased panel With a closed air gap behind the wood-based panel With an open air gap behind the wood-based panel Airbone sound absorption The sound transmission loss R of a single wood-based panel, measured in dB, is related the mean surface mass mA en kg/m² according to the following equation (which is only...

 Open the catalog to page 3

All Groupe THEBAULT catalogs and technical brochures

  1. TeboPin III

    2  Pages

  2. Tebo Pin Flam

    3  Pages

  3. TeboWall

    2  Pages

  4. TeboRoof

    2  Pages

  5. TeboPin Star

    2  Pages

  6. TeboPin Elite

    2  Pages

  7. TeboPin Clear

    2  Pages

  8. TeboFlam

    3  Pages

  9. TeboProfil

    2  Pages

  10. TeboStile

    2  Pages

  11. TeboGarant

    2  Pages

  12. TeboMarine

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.