TeboFloor II / III
3Pages

{{requestButtons}}

Catalog excerpts

TeboFloor II / III - 1

DESCR IPTION Base board: Maritime Pine throughout Plywood Faces (IAW EN 635-3): II / III Face side II Flooring and roofing applications in traditional timber framed constructions. Tight with sound knots and wooden patches. Occasional synthetic repairs. Admitting open defects Finishing: sanded 1 side Edge machining: with tongue & groove Average density (IAW EN 323): 580 kg/m3 (+/- 10%) Bonding (IAW EN 314-2): class 3 Service (IAW EN 636): class 1-2-3 (interior, humid and exterior conditions) - flooring & roofing IAW EN 12871 Formaldehyde release classification (IAW EN 13986): E1 Content of Pentachlorophenol (IAW EN 13986): PCP ≈ 0 ppm Sizes, number of plies & packaging Packing *12 mm only on roof Other sizes & thicknesses: on request Preservative treatments, fungicide & Insecticide, antitermite: optional on request Cutting & TG processing: optional on request Flat, on intermediate bearers, in an enclosed dry and ventilated building, clear of the ground. As far as storage on site is concerned, provision should be made to cover the panels with an opaque waterproof sheeting with the underside of the stacks clear of the ground. Compliance with standard practice, with regulations and with health and safety rules should be maintained at all times. Cutting and machining in the workshop possible except laser technology. PRODUCTION SITES Production on Thébault’s sites in France FURTHER PROCESSING & INSTALLATION Groupe THEBAULT 47, rue des Fontenelles - 79 460 MAGNE - France Tél : +33 (0)5 49 35 70 20 info@groupe-thebault.com

Open the catalog to page 1
TeboFloor II / III - 2

TeboFloor II / III TECHNICAL PROPERTIES Characteristic values (MPA) IAW EN 789 - 1058 for structural calculations IAW Eurocodes 12* Others characteristic values Available on DOP : Strength in: Tension (ft), Compression (fc), Panel shear (fv) and Planar shear(fr) Modulus of elasticity in: Tension (Et), Compression (Ec), Panel shear (Gv) and planar shear (Gr) Uses Use in structural applications (IAW EN 13986, IAW EN 12871, 636-3, EN 636-2, EN 636-1) Suitable for use as structural element in exterior conditions (service class 3), humid conditions (service class 2) and interior conditions...

Open the catalog to page 2
TeboFloor II / III - 3

Sound absorption coefficient Reaction to fire Frequency range End use condition In reference to table 8 of EN 13986 - 2004+A1:2015 Minimum thickness Class excluding floorings Class floorings Without an air gap behind the panel With a closed or an open air gap not more than 22 mm behind the woodbased panel With a closed air gap behind the wood-based panel With an open air gap behind the wood-based panel Airbone sound absorption The sound transmission loss R of a single wood-based panel, measured in dB, is related the mean surface mass mA en kg/m² according to the following equation (which is...

Open the catalog to page 3