1. Catalogs
  2. Gretsch-Unitas
  3. GU Fluchttuersystemloesungen

GU Fluchttuersystemloesungen

GU Fluchttuersystemloesungen
1 / 52 PagesView full catalog

GU Fluchttuersystemloesungen

Product catalog summary
Overview: The document is an order catalogue focusing on new approaches to escape door security, addressing the dual need for emergency egress and security against unauthorized access. It introduces system solutions and components designed to meet these requirements.
Principle of Escape Door Security: Escape doors must allow quick exit during emergencies while remaining secure against unauthorized entry. Panic locks are essential for this dual functionality. The document discusses the challenge of distinguishing between normal and emergency conditions and introduces a psychological barrier using an electrical locking element to prevent misuse.
System Solutions: The catalogue presents two main escape door packages:
  • Package 1 - Electrically-locking Touch Bar (EVT): Integrates panic hardware and escape door locking, featuring an LED indicator for intuitive operation. It complies with EN 1125 standards and can be networked via the BKS-NET interface.
  • Package 2 - Electrically-locking Panic Lock (EVP): Suitable for retrofitting, it combines a self-locking panic lock with electrical escape door locking, reducing planning and production time. It complies with EN 179 and EN 1125 standards.
Centralised Control and Monitoring: The BKS-NET system offers centralized control and monitoring of multiple doors, facilitating easy planning, minimal wiring, and fast commissioning. It supports local and central configuration of system components.
Escape Door Control Units: The FTNT10/20 and FTNTAP units feature modular designs, innovative signalling concepts, and compatibility with various switch ranges. They offer programmable inputs/outputs and networkability via the BKS-NET interface.
Specifications: The document provides detailed specifications for various components of an escape door control system, including dimensions, materials, and compatibility with different cylinders. Specific order numbers are provided for each variant.
Key Switches and Code Keypads: The document describes the ST10 and ST20 spring-operated key switches, highlighting their technical features. It also introduces code keypads as an alternative to key switches, offering convenient operation with individual codes.
I/O Modules: The I/O modules provide programmable inputs and outputs for integrating various systems like swing door drives and access control. They connect to escape door control units via a 2-wire BKS-NET door bus.
Power Supply Units and Accessories: The document lists several power supply units with different specifications, including switching power supplies and units for top hat rails. Accessories such as system cables and programming cables are also detailed.
Electrically-locking Touch Bar (EVT) and Panic Locks: The EVT integrates escape door locking into a touch bar, providing clear status signals. The Series 21 and Series 19 electrically-locking panic locks offer secure automatic door locking with various panic functions and approvals.
Procedures and Recommendations: Ensure compatibility of strikers and locks with the specified electric escape door strikes. Use magnetic locks in conjunction with panic locks and escape door control units for optimal security. Regularly check the functionality of built-in sensors in magnetic locks.
Standards and Approvals: Locks and components comply with standards such as DIN 18250, VdS B, EN 179, and EN 1125.
Additional Systems: The document describes additional systems like the BKS-NET Panel for door status visualization, BKS-NET System Software for programming and monitoring, and the Approach Area Monitoring System for preventing unauthorized door use.
Exclusion of Liability: The document includes a disclaimer stating that the information is based on general experience and is non-binding, with no liability for errors.
See more

Catalog excerpts

GU Fluchttuersystemloesungen-1

DOOR TECHNOLOGY - ORDER CATALOGUE

 Open the catalog to page 1
GU Fluchttuersystemloesungen-2

Locked and yet open Escape doors must ensure that people can leave a building quickly and without auxiliary means in the event of an emergency. At the same time, these doors are expected to be lockable in order to provide efficient burglar protection, e.g., on the outside of a building. Panic locks are designed to fulfil exactly these requirements. Danger recognition The fact that such escape doors can be opened from inside at any time is criticised by building operators who demand that in 'normal' conditions these doors must not be passable. From the technical point of view, however, it is not feasible...

 Open the catalog to page 2
GU Fluchttuersystemloesungen-3

Escape door control system FTNT escape door control unit – innovative signalling concept with clear straightforward symbols Door management with BKS-NET door-bus interface The HM-F-FT escape route sliding door reconciles conflicts between regulatory standards

 Open the catalog to page 3
GU Fluchttuersystemloesungen-4

System solutions for escape door security Escape door package 1 | Electrically-locking Touch Bar (EVT) In conjunction with the FTNT escape door control unit The electrically-locking Touch Bar EVT is an innovative locking system which is perfectly suited for all modern 1- or 2-leaf panic exit devices. The EVT combines panic hardware and escape door locking into one system thus reducing the number of individual components. The integrated LED indicator in the Touch Bar also makes intuitive operation possible. When locked, the door is always secured by the locking points of the panic lock. Functional...

 Open the catalog to page 4
GU Fluchttuersystemloesungen-5

Escape door locking integrated into the Touch Bar for 1- and 2-leaf timber, steel or narrow stile doors = ) Shoot-bolt lock b (not shown) 3 = Escape door terminal set 4 = Electric escape door strike 2 1 = Touch Bar (EVT) 2 = a) Panic lock = ) Shoot-bolt lock b (not shown) 3 = Escape door terminal set 4 = Electric escape door strike 2 2 1 3

 Open the catalog to page 5
GU Fluchttuersystemloesungen-6

System solutions for escape door security In the case of the EVP solution for single-leaf timber, steel or narrow stile doors, no installation of additional locking elements is unnecessary. The combination of self-locking panic lock and electrically escape door locking provides a compact solution which significantly reduces the planning and production time for architects and door fabricators. The EVP lock comes in standard DIN lock case dimensions, making it suitable for retrofitting at any time. Additional millings in the door leaf or frame (in the area above the striker) are no longer required....

 Open the catalog to page 6
GU Fluchttuersystemloesungen-7

Escape door locking and panic lock in one system for 1-leaf timber, steel or narrow stile doors 1 = Panic lock 2 = scape door terminal E (set) with integral power supply unit 3 = lectric escape door strike E with latch lock 1 = lectrically-locking panic lock E system (EVP) 2 = scape door terminal (set) with E integral power supply unit 3 = lectric escape door strike with E latch lock

 Open the catalog to page 7
GU Fluchttuersystemloesungen-8

System solutions for escape door security Eschakgrupp***™*: zuordnung b«art>«t« You want to control and monitor many doors from a central place? Then the BKS-NET panel or BKS-NET system software offer you everything you need. In reception areas, security centres, or nurses' rooms, these products give you the complete overview of a large number of data. BKS-NET interconnects the GU group's electro-mechanical systems by means of modern bus communication, thus ensuring the automatic interplay of functions. Its modern system structure comprises centralised system configuration as well as centralised system...

 Open the catalog to page 8
GU Fluchttuersystemloesungen-9

Centralised visualisation The system design FTNT10: escape door control unit with integrated emergency push-button ST10: key switch BK10: bus coupler Cx10: building bus coupler

 Open the catalog to page 9
GU Fluchttuersystemloesungen-10

Product overview, escape door security Featuring modular design, the escape door control unit FTNT10/20 allows for the implementation of tailor-made solutions for the most diverse requirements. Creative scope is provided thanks to the control unit being suitable for various switch ranges. Advantages and technical data: ■ Simple installation ■ Door release button next to the door (FTNT10) ■ Second emergency push-button for opening both leaves (FTNT20) ■ Modular design ■ Combinable with the EVP lock or the EVT Touch Bar in a system ■ Sabotage monitoring ■ Simple assembly and installation in standard flush-mounted...

 Open the catalog to page 10
GU Fluchttuersystemloesungen-11

Terminal sets &u FTNT10 terminal sets Set consisting of: ■ FTNT10 escape door control unit with integral emergency push-button ■ ST10 spring-operated key switch ■ 2-section set without power supply unit for external voltage supply (24 V DC/100 mA) ■ 3-section set with integrated in-wall power supply unit 230 V AC/24 V DC, 0.5 A, for connection of one EVP lock, one magnetic lock or up to two electric escape door strikes ■ For installation in standard flush boxes (depth 61 mm)

 Open the catalog to page 11
GU Fluchttuersystemloesungen-12

Product overview, escape door security xm The FTNTAP escape door control unit with innovative signalling concept monitors the door and releases it in the event of an emergency either automatically or upon manual operation of the emergency push-button. Advantages and technical data: ■ Simple installation ■ Door release button next to the door ■ Different versions available - green or white plastic housing - robust stainless steel housing ■ Combinable with the EVP lock or the EVT Touch Bar in a system ■ Sabotage monitoring ■ Integrated power supply unit ■ No separate control unit required ■ Programmable...

 Open the catalog to page 12
GU Fluchttuersystemloesungen-13

&u FTNTAP10 escape door terminal Consisting of: ■ Escape door control unit with - integrated emergency push-button - integrated spring-operated key switch - integrated power supply unit 100 - 230 V AC/24 V DC, 0.5 A for connection of one EVP lock, one magnetic lock or up to two electric escape door strikes ■ Freely configurable inputs and outputs - the number of inputs/outputs is extendable via IO10 or IO5 I/O modules ■ Networkable via BKS-NET door bus ■ Protection class: IP20 ■ Dimensions: 210 mm x 75 mm x 60 mm ■O n-wall mounting ■ For profile half cylinder (order length = 31 mm/35 mm) or Swiss...

 Open the catalog to page 13
GU Fluchttuersystemloesungen-14

Escpape door control system FTNT10/FTNT20/FT25 escape door control units Advantages and technical features: ■ Door release button next to the door (FTNT10) ■ Second emergency push-button for opening both leaves (FTNT20) ■ Approved in accordance with EltVTR ■ For installation in standard flush boxes (61 mm depth) ■ Nominal voltage: 24 V DC (- 15% + 10%) ■ Nominal current consumption: 80 mA ■ Protection class: IP20 Escape door control unit

 Open the catalog to page 14
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.