Catalog excerpts
ACTIVE CLOSED CHILLED BEAM
Open the catalog to page 1Catalogue, specifications subject to change © 01-2013
Open the catalog to page 2&GRRDRK6 ACTIVE CLOSED CHILLED BEAM K6 active closed climate beam for various ceiling types. The casing is made of galvanized sheet steel, powder coated, with a perforated front plate with circular perforations. Plenum manufactured from galvanized sheet steel with connection diameter of 125 mm. The heat exchanger has aluminium fins and a copper collector with a 0 15 mm connection. The K6 climate beam is Eurovent certified. TECHNICAL DETAILS APPLICATION Catalogue, specifications subject to change © 01-2013
Open the catalog to page 3Catalogue, specifications subject to change © 01-2013
Open the catalog to page 4+GRRDR Catalogue, specifications subject to change © 01-2013
Open the catalog to page 5WORKING PRINCIPLE A chilled beam is an on convection based HVAC system. The K6 chilled beam is a high-performance, active and closed chilled beam able to both cool and heat room air. This air is subsequently mixed with fresh, primary air in order to finally be blown back into the room. The primary supply air is led to a plenum from where it is blown into the room by a series of nozzles. The resulting small jets create a reduced pressure above a built-in heat exchanger, being the driving force for room air to travel through this exchanger. This cooled or heated, secondary air mixes with the...
Open the catalog to page 6Catalogue, specifications subject to change © 01-2013
Open the catalog to page 7OTHER TYPES S TYPE Catalogue, specifications subject to change © 01-2013
Open the catalog to page 8CONNECTION POSSIBILITIES 2-PIPE SYSTEM 1 connection left 4-PIPE SYSTEM 1 connection left Catalogue, specifications subject to change © 01-2013
Open the catalog to page 9ACCESSIBILITY OF HEAT EXCHANGER Catalogue, specifications subject to change © 01-2013
Open the catalog to page 109 ZRRDR Catalogue, specifications subject to change © 01-2013
Open the catalog to page 11A. CAPACITY HEAT EXCHANGER (for other selections, please contact GRADA) Selection based on: Tr [°C]: 22, Twin [°C]: 35 Catalogue, specifications subject to change © 01-2013
Open the catalog to page 12Selection based on: Tr [°C]: 26, Twin [°C]: 16 Selection based on: Tr [°C]: 22, Twin [°C]: 35 VGiwujn Catalogue, specifications subject to change © 01-2013
Open the catalog to page 13B. SOUND POWER WITHOUT ROOM ATTENUATION A NOZZLE Catalogue, specifications subject to change © 01-2013
Open the catalog to page 14Catalogue, specifications subject to change © 01-2013
Open the catalog to page 15Catalogue, specifications subject to change © 01-2013
Open the catalog to page 16Catalogue, specifications subject to change © 01-2013
Open the catalog to page 17C. PRESSURE LOSS WATER SIDE 2-pipe system 35 Catalogue, specifications subject to change © 01-2013
Open the catalog to page 18D. AIR VELOCITY EXPLANATORY DRAWING Catalogue, specifications subject to change © 01-2013
Open the catalog to page 19+BRRDR Catalogue, specifications subject to change © 01-2013
Open the catalog to page 20•onnon Catalogue, specifications subject to change © 01-2013
Open the catalog to page 21+BRRDR Catalogue, specifications subject to change © 01-2013
Open the catalog to page 22Catalogue, specifications subject to change © 01-2013
Open the catalog to page 23C: nom. length heat exchanger [mm] L: nom. length chilled beam [mm] V: with deflection vanes -: no deflection vanes C: cooling only (2 pipe system) H: cooling & heating (4 pipe system) A, B, C, D: nozzle type L: left connection R: right connection G: left connection with 2 air inlets (recommended for primary airflow rates larger than 140 m³/h) D: right connection with 2 air inlets (recommended for primary airflow rates larger than 140 m³/h) T type (standard) Z type S type V type Catalogue, specifications subject to change © 01-2013
Open the catalog to page 24All GRADA International catalogs and technical brochures
-
SLS_2024
11 Pages
-
MCAS
5 Pages
-
CS400_2022
4 Pages
-
WR230
5 Pages
-
VRK 233
6 Pages
-
RDR
8 Pages
-
RLV Brochure
11 Pages
-
WP100P
3 Pages
-
DP100S • DP100T
2 Pages
-
A-170 • G-170
3 Pages
-
G-100
3 Pages
-
SLS
6 Pages
-
A780
3 Pages
-
BB
13 Pages
-
SPB
2 Pages
-
GK250
2 Pages
-
WGC
1 Pages
-
DA350
3 Pages
-
SPP
2 Pages
-
SPS
2 Pages
-
SLB
2 Pages
-
SLF
3 Pages
-
VF750
2 Pages
-
GT007
2 Pages
-
URSIL
1 Pages
-
KA
2 Pages
-
RVC
2 Pages
-
BR
13 Pages
-
BS
19 Pages
-
SP900
1 Pages
-
SP800
2 Pages
-
SP700
1 Pages
-
LP400
4 Pages
-
LP300
4 Pages
-
DP100
2 Pages
-
DP150
2 Pages
-
DP100P
6 Pages
-
SP100
2 Pages
-
WBP
2 Pages
-
WO331
2 Pages
-
VF045
2 Pages
-
WB900
2 Pages
-
W-801
2 Pages
-
W331
2 Pages
-
JD Short pipe
4 Pages
-
JD Long Pipe
4 Pages
-
VT061
2 Pages
-
RLV
12 Pages
-
AG300
2 Pages
-
AV500
2 Pages
-
Z600
4 Pages
-
VM
2 Pages
-
AK700
7 Pages
-
WR210
3 Pages
-
WS210
3 Pages
-
WS200
4 Pages
-
WS400
3 Pages
-
WR400
2 Pages
-
WR200
2 Pages
-
WR250
2 Pages
-
WT100
4 Pages
-
WS360
2 Pages
-
WT500
3 Pages
-
WR300
2 Pages
-
SE700
2 Pages
-
SE900
2 Pages
-
SE800
2 Pages
-
RT151
4 Pages
-
TE600
4 Pages
-
LT360
12 Pages
-
LT350
12 Pages
-
AS100
4 Pages
-
AH700
3 Pages
-
CB780
2 Pages
-
FH100
4 Pages
-
CB400
2 Pages
-
A250
2 Pages
-
A980
2 Pages
-
GK150
2 Pages
-
A600
9 Pages
-
GP360
2 Pages
-
A710
4 Pages
-
False ceiling
6 Pages
-
EE200
2 Pages
-
EE300
2 Pages
-
EE400
2 Pages
-
DC570
2 Pages
-
DC560
2 Pages
-
DR160
2 Pages
-
EG400
2 Pages
-
TE370
2 Pages
-
CC600
2 Pages
-
CE100
2 Pages
-
DA370
2 Pages
-
DA360
2 Pages
-
DG60
6 Pages
-
TS600
4 Pages
-
TS750
2 Pages
-
DG360
3 Pages
-
MCAS
3 Pages
-
CS400
21 Pages
-
WGR-WGS_PI
2 Pages
-
MSS
8 Pages
-
A100-G100_PI
4 Pages
-
FALSE CEILING DIFFUSERS
6 Pages
-
CS500
2 Pages
-
Z-600
2 Pages
Archived catalogs
-
Select & Go
41 Pages
-
K-30
6 Pages
-
G-801
2 Pages
-
SE600
2 Pages
-
WT100S
2 Pages
-
CE100 / DE100
2 Pages
-
A-100 / G-100
4 Pages