1. Catalogs
  2. GLASS 1989
  3. Noor Steam Module
video corpo
cad

Noor Steam Module

Noor Steam Module

Noor Steam Module

Product catalog summary
Warnings and Precautions:
  • Product dimensions are specified in millimeters with a tolerance of ±5 mm.
  • Ensure adequate height at the installation site for operations.
  • Product modifications may occur without prior notice from the manufacturer.
General Norms:
  • Products comply with Low Tension Directive 2014/35/UE and Electromagnetic Compatibility Directive 2014/30/UE, supported by standards EN 60335-1, EN 60335-2-105, EN 55014-1, and EN 55014-2.
Installation Requirements:
  • Verify transport routes and installation site dimensions.
  • Installation must be conducted by qualified personnel following IEC standards.
  • Ensure surfaces are level and suitable for installation.
  • Electrical and plumbing installations must comply with local regulations.
Steam Bath and Generator:
  • Steam bath rooms must be well insulated to maintain a minimum temperature of 20°C.
  • Steam generator water supply should have pressure between 150 and 350 kPa, hardness between 10°F and 40°F, and conductivity between 300 and 1250 μS/cm.
Plumbing and Electrical Specifications:
  • Qualified technicians must handle plumbing and electrical installations.
  • Water pressure should not exceed 350 kPa; use a pressure reducer if necessary.
  • Electrical systems must comply with IEC 364-1 and national laws.
  • Install a differential switch and circuit breaker near the appliance.
Specifications:
The document outlines the necessary specifications for connecting the product to a power box, emphasizing the use of a type H07 RN-F cable of adequate size. The earth terminal must be longer than the phase and neutral conductors. The earth cable must be permanently connected to the electrical mains, and the manufacturer is not liable for defects due to improper earthing.

Equipotential Connection:
The appliance must be connected to the room's equipotential system. A 30mA differential switch and a class III overvoltage circuit breaker are required, with specific installation guidelines to ensure safety and compliance with international and national standards.

Installation Requirements:
Attention must be paid to the dimensions of the product packaging and the transport route to the installation site. The installation must be performed by qualified personnel according to CEI standards, ensuring the supporting surfaces are level and can bear the product's weight. The installer must verify the conformity of the building's installations before proceeding.

Steam Bath Installation:
For models with a steam bath feature, the room must be well insulated to maintain a minimum temperature of 20°C (68°F). Proper insulation is crucial to prevent performance issues.

Plumber Specifications:
The dynamic pressure of the water supply must match the product's technical specifications. If pressure exceeds 350 kPa, a pressure reducer is necessary. Water filters are recommended to prevent issues from impurities.

Electrician Specifications:
The electrical supply system must comply with international and national standards. A stabilizing device is recommended for unstable electrical networks to protect the product from overvoltage or overcurrent.

Power Box Connection:
For versions with a power box, use a type H07 RN-F cable. The earth terminal must be longer than the phase and neutral conductors. The manufacturer is not responsible for issues due to improper earthing.

Safety and Compliance:
All installations must adhere to international and national safety standards, especially in bathrooms, to prevent electrical hazards.
See more

Catalog excerpts

Noor Steam Module-1

1 Le dimensioni d’ ingombro sono espresse in mm 2 Tolleranze dimensionali sulle misure reali ± 5 mm 3 Prestare particolare attenzione alle dimensioni di ingombro dei prodotti. 4 Per una corretta installazione del prodotto e necessario verificare che I’altezza del locale sia sufficiente per le operazioni d’installazione. 5 La casa costruttrice si riserva il diritto di apportare in qualsiasi momento modifiche e migliorie al prodotto senza dare preavviso. 2 Dimensional tolerance on real size ± 5 mm. 3 Pay special attention to the overall dimensions of the products 4 For a corrected installation of the product it is necessary to verify that the height of the room is sufficient for the installation operations. 5 The manufacturer reserves the right to carry out product modifications and improvements at any time without prior notice. 1 Die AuGenmaGe werden in Millimetern angegeben. 2 GroGenabweichungen gegenuber den reellen MaGen ±5 mm 3 Achten Sie insbesondere auf die AuGenmaGe der Produkte. 4 Zur einwandfreie montage des Produktes es ist notwendig, zu uberprufen, dass die Hohe des Raumes fur die Installationsbetriebe genugend ist 5 Der Hersteller behalt sich das Recht vor, jederzeit und ohne Vorankundigung Anderungen und Verbesserungen an den Produkten vorzunehmen. 1 Las dimensiones estan expresadas en mm. 2 Tolerancias dimensionales en las medidas reales ± 5 mm. 3 Prestar particular atencion a las dimensiones maximas de los productos. 4 Para la correcta instalacion del producto es necesario controlar que la altura del local sea suficiente para las operaciones de instalacion. 5 El fabricante se reserva el derecho de aportar en cualquier momento modificaciones y mejonas al producto sin previo aviso. 1 Les dimensions d’encombrement sont exprimees en mm. 2 Tolerances sur les dimensions reelles ± 5 mm. 3 Faire extremement attention aux dimensions d’encombrement des produits. 4 Pour une correcte installation du produit il est necessaire de verifier que la hauteur du local soit suffisante pour les operations d'installation 5 Le Fabricant se reserve le droit d’apporter, a tout moment et sans preavis, des modifications et des ameliorations au produit. AZIENDA CON SISTEMA DI GESTIONE QUALITA CERTIFICATO DA DNV GL = ISO 9001 =

 Open the catalog to page 1
Noor Steam Module-2

REQUISITI PER L’INSTALLAZIONE DEL PRODOTTO Fare ATTENZIONE alle dimensioni degli imballi del prodotto acquistato! Verificare il percorso per il trasporto del prodotto, al sito prescelto per l'installazione, verificando le misure di porte, scale, pianerottoli, corridoi. L’installazione va eseguita da personale qualificato nel rispetto delle norme IEC. L’installatore deve assicurarsi preventivamente che il pavimento e/o parete dove verrà installato il prodotto sia sufficientemente livellato, che ne possa sopportare il peso e che vi siano le predisposizioni tecniche necessarie. Deve inoltre verificare...

 Open the catalog to page 2
Noor Steam Module-3

REQUIREMENTS FOR INSTALLING THE PRODUCT Pay ATTENTION to the dimensions of the packages of the purchased product! Check the route for transporting the product, to the selected installation site, checking the measurements of: doors, stairs, landings, corridors Installation must be carried out by qualified personnel in accordance with IEC standards. The installer must make sure in advance that the floor and/or wall where the product will be installed is sufficiently level, capable of supporting the weight and that there are the necessary technical arrangements. He must also check that the surfaces...

 Open the catalog to page 3
Noor Steam Module-4

VORAUSSETZUNGEN FÜR DIE INSTALLIERUNG DES PRODUKTS ACHTEN Sie auf die Maße der Verpackungen des erworbenen Produkts! Überprüfen Sie den Transportweg des Produkts zum vorgesehenen Installationsort. Achten Sie dabei besonders auf die Maße von: Türen, Treppen, Treppenabsätzen, Fluren. Die Installation muss von qualifiziertem Personal gemäß den Normen CEI ausgeführt werden. Der Installateur muss im Voraus sicherstellen, dass der Boden und/oder die Wand, an denen das Erzeugnis installiert werden wird, angemessen nivelliert sind, diese das Gewicht von tragen können, sowie dass die erforderlichen technischen...

 Open the catalog to page 4
Noor Steam Module-5

REQUISITOS PARA INSTALAR EL PRODUCTO ¡PRESTE ATENCIÓN a las dimensiones de los embalajes del producto que ha adquirido! Compruebe el recorrido para transportar el producto al lugar elegido para instalarlo, comprobando las medidas de: las puertas, las escaleras, los rellanos, los pasillos. La instalación se efectúa por personal cualificado y cumpliendo las normas IEC. El instalador debe comprobar antes que el suelo y/o la pared donde se instalará el producto estén bien nivelados, que puedan soportar el peso y que cumpla con los requisitos técnicos necesarios. Además debe comprobar que las superficies...

 Open the catalog to page 5
Noor Steam Module-6

EXIGENCES POUR L'INSTALLATION DU PRODUIT Faites ATTENTION aux dimensions des emballages du produit que vous avez acheté ! Vérifier le parcours pour le transport du produit au site choisi pour l'installation en vérifiant les mesures des: portes, escaliers, paliers, couloirs. L'installation doit être effectuée par du personnel qualifié dans le respect des normes IEC. L'installateur doit s'assurer au préalable que le sol et/ou le mur où le produit sera installé soit suffisamment nivelé, qu'il soit en mesure de supporter son poids du produit et qu'il possède les prédispositions techniques nécessaires....

 Open the catalog to page 6
Noor Steam Module-7

noor steam module colonna ad appoggio/wall-mounted column Dati Tecnici - Technical Data - Technische Daten - Datos Tecnicos - Données Techniques Peso netto - Net weight - Nettogewicht - Peso neto - Poids net Caratteristiche Idrauliche - Hydraulic Features - Hydraulische Eigenschaften Características Hydráulicas - Caractéristiques Hidrauliques Dimensioni dell’attacco sul carico caldaia - Socket dimensions on boiler supply - Anschlussmaße zur Heizungseinlass Dimensiones de la conexión en el carga caldera - Dimension du raccord sur tuyau de chargement de la chaudière * si consiglia di installare...

 Open the catalog to page 7

All GLASS 1989 catalogs and technical brochures

  1. Mimesi Panel

    10  Pages

  2. Steam Plus

    12  Pages

  3. hoshi

    11  Pages

  4. Nuvola Open

    3  Pages

  5. eden

    8  Pages

  6. nubea round

    8  Pages

  7. linea duo

    11  Pages

  8. mawi

    10  Pages

  9. queen

    2  Pages

  10. chloe

    2  Pages

  11. denver

    2  Pages

  12. momoa

    2  Pages

  13. Bloom

    4  Pages

  14. Meilin

    2  Pages

  15. Alchemy

    2  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About ArchiExpo
ArchiExpo is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. ArchiExpo is an entity of VirtualExpo Group.