Catalog excerpts
PRODUCT CATALOGUE PRODUCT CATALOGUE Visit www.gewiss.com and follow us on: GEWISS S.p.A. Registered office Via A. Volta, 1 - 24069 CENATE SOTTO (Bergamo) - Italy Tel. +39 035 946 111 - Fax +39 035 945 222 gewiss@gewiss.com - www.gewiss.com Sole Shareholder company - Bergamo Register of Companies/ VAT / Tax code (IT) 00385040167 REA 107496 - Share Capital 60,000,000.00 EUR fully paid up
Open the catalog to page 1GEWISS Group PRODUCT CATALOGUE The technologically advanced range of modular and moulded-case devices joins the vast range of distribution boards and cabinets, enclosures and combined boards to create the Gewiss Protection System. PRODUCT CATALOGUE GEWISS is an international leader in the production of systems and components for low voltage electrical installations. The fact that development is seen as a constant management feature has permitted GEWISS to assert itself as a reference interlocutor for the electrotechnical market in the creation of solutions for domotics, energy and the...
Open the catalog to page 2GEWISS Protection System The GEWISS protection system is made up of products that work together perfectly, such as the innovative 90 ReStart range (automatic reclosing devices), the 90 MCB and 90 RCD ranges (modular circuit breakers for circuit and residual current protection), the MTX range (MCCBs for power distribution) and the 47 CVX range (metal distribution boards). An integrated selection of products to meet every possible need for the specific application - from residential to industrial - and to guarantee quality and safety in line with the market requisites. The GEWISS system offers...
Open the catalog to page 3Automatic reclosing devices 90 ReStart RESTART WITH AUTOTEST
Open the catalog to page 490 ReStart AUTOMATIC RECLOSING DEVICES Automatic Reclosing Devices ReStart If the residual current device trips, ReStart restores the electricity supply quickly, but only after carrying out a system check (RD versions) and also a short-circuit check (RM version). tic automa The only device g reclosin e RCCB sts th that te off cutting without pply tricity su the elec Thanks to the innovative control logic, Autotest can regularly and automatically test the working of the residual current device without ever disconnecting the system from the power supply. ReStart with Autotest 2P PRO versions...
Open the catalog to page 6(*) It's possible to choose the automatic reclosing mode: • with a system check • by attempts • remote (**) It's possible to set the automatic reclosing time delay. (***) For 4P versions only
Open the catalog to page 7NOTE: ARD must be supplied with 230 V AC phase-neutral for working.
Open the catalog to page 8NOTE ARD must be supplied with 230 V AC phase-neutral for working GW90967 and GW90969 ARDs can be coupled with RCCB's IDP 2 poles * Accessories not available **RCCB with Neutral on the left
Open the catalog to page 9NOTE: ARD must be supplied with 230 V AC phase-neutral for working.
Open the catalog to page 10NOTE: they are also compatible with RCBO's 1P+N and 2 poles (MDC 1P+N e 2P). ARD must be supplied with 230 V AC phase-neutral for working.
Open the catalog to page 11Automatic reclosing device with/without circuit safety and/or short-circuit check. DEVICES TO BE COUPLED WITH MCBs AND ADD-ON RCDs 4 POLES NOTE: they are also compatible with MTC MCBs, MDC RCBOs, MT MCBs and BD add-on RCDs 1P+N, 2 and 3 poles. ARD must be supplied with 230 V AC phase-neutral for working.
Open the catalog to page 12RESTART WITH AUTOTEST (1) Power supply 230V phase-neutral (2) In the absence of a system fault (3) Average daily temperature < +35°C (4) Choosing NC + impulse option, auxiliary contact switches for 100ms at the end of each cycle of Autotest carried out successfully.
Open the catalog to page 13(1) Power supply 230V phase-neutral (2) In the absence of a system fault (3) Average daily temperature < +35°C
Open the catalog to page 14(1) For IT system reclosing without fault check (2) Power supply 230V phase-neutral (3) Impulse duration > 200ms (4) In the absence of a system fault (5) Average daily temperature < +35°C (6) Automatic reclosure delay time: 0-1h
Open the catalog to page 15Modular circuit breakers for circuit protection 90 MCB MTC - COMPACT MINIATURE CIRCUIT BREAKERS
Open the catalog to page 16MT - MINIATURE CIRCUIT BREAKERS MTHP - HIGH PERFORMANCE MINIATURE CIRCUIT BREAKERS
Open the catalog to page 17MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION MCBs for circuit protection With the compact MCBs MTC you can protect 2 poles for each module. The MT MCBs, based on unique and innovative design solutions and the use of high quality materials, stand out for their optimum performance, robustness and long-term reliability. The high-performance MTHP MCBs - up to 125A and with a breaking capacity of 16kA (EN 60947-2) - can be used both as a main switch and as circuit breaker protection in electrical boards with a high short-circuit current. MCB - MTC Miniature circuit breakers Compact GEWISS...
Open the catalog to page 18TRIPPING CHARACTERISTICS IN ALTERNATING CURRENT (EN 60898) MTC 45 - 60 - 100 Characteristic C MT 45 - MT 60 - 100 - 250 Characteristic C MTHP 160 - 250 Characteristic C Tripping characteristic MT 60 - 100 Characteristic D MTHP 160 Characteristic D In =rated current Inf = conventional non-trpping current If = conventional tripping current t = tripping time B tripping curve: tripping characteristic for the protection of electrical resistive loads (for example: heating) and very long electrical ditribution lines. C tripping curve: tripping characteristic for the protection of general...
Open the catalog to page 19* Miniature circuit breakers with neutral on the left
Open the catalog to page 20Residual current protection circuit breakers 90 RCD MDC - MONOBLOC COMPACT RCBO’S
Open the catalog to page 22BD – ADD-ON RESIDUAL CURRENT DEVICES FOR MINIATURE CIRCUIT BREAKERS IDP - RESIDUAL CURRENT CIRCUIT BREAKERS
Open the catalog to page 23MODULAR CIRCUIT BREAKERS FOR RESIDUAL CURRENT PROTECTION RCBOs, RCCBs and ADD-ONs for residual current protection With the compact MDC RCBOs, you can protect one pole for each module. A range of modular devices for residual current protection at the forefront of performance. The IDP RCCBs and add-on BD and BDHP RCDs for MT and MTHP circuit breakers offer quick assembly and unique innovation solutions. Residual current circuit breakers with overcurrent protection Compact GEWISS Wide range of versions: - instantaneous: type AC - A - impulse resistant: type A - B overall dimensions -...
Open the catalog to page 24All GEWISS catalogs and technical brochures
-
trade-catalogue
1293 Pages
-
GW60001FH
1 Pages
-
ESALITE FL - technical sheet
2 Pages
-
97 MSS - technical sheet
8 Pages
-
24 SC - technical sheet
4 Pages
-
GWF1410GG830
2 Pages
-
GWA1514
1 Pages
-
Smart building
17 Pages
-
Lighting innovations
43 Pages
-
Road [5]
16 Pages
-
Solution for construction sites
16 Pages
-
Domo center
20 Pages
-
DOMOTICS POWER BUILDING TRADE CATALOGUE
1616 Pages
-
MAVIL CATALOGUE
111 Pages
-
LIGHTING TRADE CATALOGUE
380 Pages
-
Chorus - Home Automation
35 Pages
-
Smart 4 - LED
32 Pages
-
Chorus YES
60 Pages
-
Lighting
359 Pages
-
Building
666 Pages
-
Power
291 Pages
-
Smart[4]
4 Pages
-
DEDALO
4 Pages
-
GLOB
4 Pages
-
INDY
4 Pages
-
HORUS 1
4 Pages
-
Street [O3] Urban [O3]
72 Pages
-
Energy DIN - BLOC - BOX
958 Pages
-
CLICK 21 and ZNT Ranges
2 Pages
-
AVENUE 3