Regular Fiberboard Sheathing: Installation Instructions
2Pages

{{requestButtons}}

Catalog excerpts

Regular Fiberboard Sheathing: Installation Instructions - 1

Regular Fiberboard Sheathing Installation Instructions General • eorgia-Pacific Regular Fiberboard Sheathing (previously G referred to as regular impregnated sheathing) minimizes the waviness that often occurs when lap sidings are installed over other thin, less stiff types of sheathing. • egular Fiberboard Sheathing allows water vapor generated R inside the building to pass through the wall cavity, thus preventing trapping of water vapor within the wall. • egular Fiberboard Sheathing is an environmentally sensitive R wood product, manufactured from previously discarded wood resources and recovered fiber material. Regular Fiberboard Sheathing (non-structural must be corner braced) Fastener Size Spacing Edges Field N ails used should be 11 ga. galvanized roofing nails with a nominal 3 ⁄8( diameter head. Staples may be used in lieu of nails. If staples are used, they should conform to the following specifications: 16 ga., .057( minimum thickness, .063( minimum width, 11⁄2( minimum length, 7⁄16( minimum crown. Staples should be applied with crown parallel to long dimension of framing members. • egular Fiberboard Sheathing allows attainment of up to R R-17.5 with 2 x 4 studs when used in conjunction with R-13 fiberglass insulation, depending on siding used. Uses • ommercial and residential above-ground wall C applications. • nderlayment under wood, vinyl, aluminum, lumber, brick, U hardboard and fiber cement siding. Sizes Regular Fiberboard Sheathing is available in nominal 1⁄2( x 4* x 8* and 4* x 9* square edge sheets. Also available coated 6 sides (C6S). Check local distributor for availability. Properties R-Value* 1.32 Vapor Permeance (Perms) Product and Test Method Standards** ASTM C208 ASTM C209 * -value shown is based on ASTM Test C-518, C-177 or C-236 at R 75° mean temperature. R means resistance to heat flow. The higher the R-value, the greater the insulating power. ** eplaces ANSI A194.1. R Application ⁄ ( Regular Fiberboard Sheathing can be applied over studs up to 16( o.c., with adequate corner bracing. When used as a wall sheathing, Regular Fiberboard Sheathing shall be covered by a water-resistive barrier and an approved wall covering in accordance with the applicable building code. A continuous vapor retarder (one perm or less) must be applied on the warm (living) side of the perimeter wall framing members. Sheathing should be applied vertically with the long edges parallel to the vertical studs. Center all joints over the framing members with a 1⁄8( gap between edges and around doors and windows. Sheathing should extend from sill to top plate. If not, headers for adequate nailing should be provided at all horizontal joints. Fasten sheathing to the intermediate studs first, then edges. Space fasteners as noted in the preceding table. Drive fasteners flush with surface. Do not countersink. Panels are cut scant to allow a 1⁄8( space required between panels. Sheathing must be dry at time of siding installation. Storage Sheathing should be stored flat, and supported and protected from direct contact with the ground. Sheathing must not be stored in a heated warehouse and should be allowed to come to equilibrium at job site conditions prior to application. Sheathing should also be kept dry and protected from rain.

Open the catalog to page 1
Regular Fiberboard Sheathing: Installation Instructions - 2

Installation Instructions (continued) Caution GP Sheathing products are marked with a hazard label because they may be a potential fire hazard if exposed to flame, such as plumbing torches. Caution must be taken that these products do not come in contact with open flame or with temperatures high enough to ignite them or cause smoldering combustion. Regular Fiberboard Sheathing products should not be used under stucco. Recommendations for Repair of Overdriven Fasteners, Holes and Damaged Areas Overdriven Fasteners If fasteners are overdriven such that they penetrate the face of Regular...

Open the catalog to page 2

All Georgia Pacific catalogs and technical brochures

  1. BLUERIBBON

    2 Pages

  2. GP LAM® LVL

    24 Pages

  3. 621519

    1 Pages

  4. 592509

    1 Pages