The document provides instructions for emergency eyewash and shower systems designed according to UNI 9608/93 regulations. These systems are crucial for quickly removing hazardous substances from the body. Users, with medical advice, should plan first aid interventions, considering some substances may react with water.

General Features
Installation must be performed by specialized personnel. The system should maintain a supply pressure between 0.2 and 0.5 MPa. The installation area must be well-lit and obstacle-free. The washing liquid temperature should be between 15 and 35°C, requiring a heating system if necessary. Eyewash units need a minimum flow rate of 6 l/min at 0.2 MPa for 15 minutes, with nozzles positioned 800-1150 mm from the ground. Emergency showers require a minimum flow rate of 100 l/min.

Installation Instructions
The emergency shower should be installed with a vertical axis, 2200±100 mm from the floor. Ensure a suitable area for water drainage. Steps include fixing the preassembled base to the floor, attaching the basin, and connecting the feeding and drain pipes.

Maintenance
Regular inspections by qualified personnel are necessary. Tests include activating the device to ensure functionality and checking water jet uniformity. Damaged parts should be replaced with originals. Temporarily out-of-service equipment must be clearly marked, with alternative devices indicated nearby.
See more

Catalog excerpts

GW12 02 04 05-1

LAVAOJOS DE EMERGENCIA EMERGENCY EYEWASH Manual de instrucciones Instruction manual

 Open the catalog to page 1
GW12 02 04 05-2

INSTRUCCIONES DE INSTALACIÓN, OPERACIÓN Y MANTENIMIENTO DEL LAVAOJOS DE EMERGENCIA GW12 02 03 05 – GW12 02 04 05 Lea estas instrucciones atentamente e instruya al personal responsable del uso. INTRODUCCIÓN Los rociadores y lavaojos de emergencia se diseñan según las indicaciones de la normativa UNI 9608/93 y se utilizan para lavar rápidamente a los operadores contaminados por sustancias peligrosas para la salud para retirarlas lo más rápido posible del cuerpo. El usuario decidirá, con la ayuda de un médico, un plan de intervención de primeros auxilios teniendo en cuenta que existen sustancias...

 Open the catalog to page 2
GW12 02 04 05-3

• El rociador de emergencia rosa (con forma de hongo) debe instalarse con el eje vertical y a una distancia de 2.200±100 mm del nivel del suelo. • El eje del cono del líquido de lavado debe encontrarse a una distancia mínima de 400 mm del obstáculo más próximo. IMPORTANTE: Puesto que los rociadores no incorporan drenaje, debe existir una zona adecuada para transportar y recoger el agua, esperándose, cuando se requiera, la realización de tratamiento especial para evitar la contaminación del medio ambiente. 1. Fije la base premontada “A” al suelo con anclajes atornillados. 2. Enrosque el lavabo...

 Open the catalog to page 3
GW12 02 04 05-4

MANTENIMIENTO Debe ponerse en práctica un plan de inspección regular para cada unidad. La inspección debe ser realizada por personal cualificado que examinará el estado de los equipos y sus componentes. Se recomienda aplicar las siguientes pruebas de funcionamiento: • Active el dispositivo para verificar que funciona correctamente y que el suministro de agua está presente. • Compruebe que el chorro de agua es uniforme y está bien ventilado (lavaojos); de lo contrario, desmonte los componentes y lávelos con agua corriente. • Si encuentra piezas dañadas o averiadas, reemplácelas con piezas originales....

 Open the catalog to page 4
GW12 02 04 05-5

Instructions for installation, operation and maintenance of emergency eyewash GW12 02 03 05 - GW12 02 04 05 Read these instructions carefully and instruct the staff in charge of use. The showers and emergency eyewash are designed following the indications of the regulation UNI 9608/93, are used to wash quickly operators invested by substances dangerous to health to remove as quickly as possible these substances from the body. It is the user that decide, with the help of a doctor, an intervention plan of first aid, taking into account that there are substances that react upon contact with water...

 Open the catalog to page 5
GW12 02 04 05-6

• The axis of the cone of washing liquid must be at least 400 mm. to the nearest obstacle. IMPORTANT: Since the showers are not equipped with drain, there should be an area suitable for the conveyance and collection of water expecting, where required, the execution of special treatment to avoid pollution of the ambient. 1. Fix the preassembled base “A” to the floor with screw anchors 2. Screw the basin “I” on the pre-assembled base “A”. 3. Connect the feeding pipe to the ball valve (PUSH). 4. Connect the drain pipe 1”1/4.

 Open the catalog to page 6
GW12 02 04 05-7

MAINTENANCE There must be a periodic inspection plan for each unit. The inspection must be performed by qualified personnel who will examine the state of the equipment and its components. It is recommendable to use the following function tests: • Activate the device to make sure it works properly and that the water supply is present. • Check that the jet of water is uniform and well-ventilated (eyewash) otherwise disassembling the components and wash them under running water • If you find damaged parts or not working should be replaced with original parts. • In case of temporary out of service...

 Open the catalog to page 7
GW12 02 04 05-8

WASHROOM EQUIPMENT & COMP. Av. Joan Carles I, 46-48 08908 L´Hospitalet de Llobregat - Barcelona - (SPAIN) www.genwec.com

 Open the catalog to page 8

All Genwec catalogs and technical brochures

  1. CATALOG 4.0

    198  Pages

  2. GW13 12 06 02

    16  Pages

  3. GW13 10 06 02

    5  Pages

  4. GW13 11 06 02

    7  Pages

  5. GW13 16 06 03

    6  Pages

  6. GW13 16 06 02

    6  Pages

  7. GW13 18 06 02

    5  Pages

  8. GW13 20 04 01

    12  Pages

  9. GW13 20 06 02

    8  Pages

  10. GW13 21 06 02

    6  Pages

  11. GW13 21 06 03

    6  Pages

  12. GW12 01 04 05

    8  Pages

  13. GW12 02 03 05

    8  Pages

  14. GW12 03 03 05

    8  Pages

  15. GW12 03 04 05

    8  Pages

  16. GW12 04 03 05

    12  Pages

  17. GW12 04 04 05

    12  Pages

  18. GW12 05 03 05

    12  Pages

  19. GW11 08 03 00

    3  Pages

  20. GW11 08 04 01

    3  Pages

  21. GW11 08 04 02

    3  Pages

  22. GW11 09 03 00

    3  Pages

  23. GW11 09 04 01

    3  Pages

  24. GW11 09 04 02

    3  Pages

  25. GW11 22 04 01

    2  Pages

  26. GW11 22 04 02

    2  Pages

  27. GW11 23 04 01

    3  Pages

  28. GW11 23 03 00

    3  Pages

  29. GW11 24 03 00

    3  Pages

  30. GW11 24 04 01

    3  Pages

  31. GW11 24 11 00

    3  Pages

  32. GW11 32 09 00

    2  Pages

  33. GW09 01 04 01

    8  Pages

  34. GW08 50 04 01

    12  Pages

  35. GW08 51 04 01

    12  Pages

  36. GW08 55 04 01

    2  Pages

  37. GW08 58 04 01

    2  Pages

  38. GW05 32 04 02

    2  Pages

  39. GW04 20 04 01

    8  Pages

  40. GW03 27 04 01

    2  Pages

  41. GW03 28 04 01

    2  Pages

  42. GW02 08 01 03

    8  Pages

  43. GW01 26 03 00

    2  Pages

  44. GW01 26 04 01

    2  Pages

  45. GW01 26 04 02

    2  Pages

  46. GW01 16 01 00

    20  Pages

  47. GW03 19 01 00

    2  Pages

  48. GW03 18 01 04

    2  Pages

  49. GW03 18 01 00

    2  Pages

  50. GW03 27 04 01

    2  Pages

  51. GW03 16 04 02

    2  Pages

  52. GW03 24 04 01

    2  Pages

  53. GW03 04 04 02

    2  Pages

  54. GW03 04 04 01

    2  Pages

  55. GW03 11 04 02

    2  Pages

  56. GW03 10 04 02

    2  Pages

  57. GW03 13 04 01

    2  Pages

  58. GW03 12 04 01

    2  Pages

  59. GW03 10 04 01

    2  Pages

  60. GW03 08 04 02

    2  Pages

  61. GW03 28 04 01

    2  Pages

  62. gw03 02

    1  Page

  63. gw03 05

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.