Product Overview
Premium Preheat 250 CS/CL A is an air-air heat recovery ventilation heat pump available in right- or left-handed versions. It features an aluminum counter current heat exchanger, a heat pump with cooling function, integrated pre-heater, supply and extract air fans, F7 supply air filter, M4 extract air filter, and Optima 301 automatics with a control panel.
Specifications
  • Dimensions: 600 x 1185 x 492 mm
  • Weight: 97 kg
  • Electrical connection: 1 x 230 V + N + PE, 10 A, 50 Hz (without reheater); Max. 1.8 kW, 16 A (with reheater)
  • Fans: EC motor, IP 44, max speed 3320 rpm, power consumption 71 W
  • Compressor: NB 6165 GK / NEK 6210 GK
  • Refrigerant: R407c, 1000 g
Performance
  • Air volume: Up to 325 m³/h at 100 Pa
  • Heating performance: 2370/2530 W at 300 m³/h, 2°C fresh air
  • COP: 7.84/5.35 at 300 m³/h, 2°C fresh air
  • Cooling capacity: 823/1110 W at 26°C supply air, 24°C extract air
Control Panel Features
  • Adjustable fan speed (0-4)
  • Extended operation timer (0-9 hours)
  • Reheater control
  • Filter alarm reset
  • Temperature setting
Construction
  • Cabinet: Sandwich construction with hot galvanized plate, 30 mm insulation, powder-coated white RAL 9010
  • Duct connection: Ø160 mm with rubber sealing ring
  • Counter current heat exchanger: Aluminum
  • Condensation trays and drain: Stainless steel
Applications
Suitable for dwellings requiring heat recovery ventilation and comfort heating or cooling. The system preheats fresh air using recovered heat from extract air, contributing to home heating or cooling as needed.
Technical Data
  • Working temperature range: -15°/+35°C
  • Min. air volume: 100/150 m³/h (CS/CL)
  • Power consumption (max., heat pump): 302/473 W (CS/CL)
  • Current consumption (max., heat pump): 1.3/2.1 A (CS/CL)
Sound Data
Sound levels measured at various frequencies and fan speeds, with detailed data provided for different operational conditions.
See more

Catalog excerpts

Premium Preheat 250 CS/CL A-1

PREMIUM PREHEAT 250 CS/CL A Product description Premium Preheat 250 CS/CL A is suitable in dwellings where a combination of heat recovery ventilation and supply of comfort heating or cooling with the supply air is desired. Before the fresh air is drawn into the house, heat is supplied to it in the counter current heat exchanger - heat recovered from the extract air. Then additional heat is supplied to the supply air by the heat pump and thereby it contributes to the home heating. If it is desired that cooling is supplied to the air instead, this is also possible. The supply air filter ensures that dirt and pollen is not brought into the house. Premium Preheat 250 CS/CL A can deliver an air volume of up to Premium Preheat 250 CS/CL A is an air-air heat recovery ventilation heat pump which is equipped with the following: An aluminum counter current heat exchanger, a heat pump with cooling function, a pre-heater integrated in the heat pump, supply and extract air fans, F7 supply air filter, M4 extract air filter, and complete Optima 301 automatics with a control panel. Premium Preheat 250 CS/CL A can be delivered with the following accessories: -- Electrical reheater for Ø160 mm duct appr. 325 m3/h at an external pressure of 100 Pa. Types Premium Preheat 250 CS/CL A is available in a right- or lefthanded version Premium Preheat 250 CS/CL A (right-handed) Dimensions in mm. Lokation: 01. Fresh air Ø160 02. Exhaust air Ø160 03. Extract air Ø160 04. Supply air Ø160 05. Counter current heat exch. 06. Supply air fan 07. Extract air fan 08. Extract air filter 09. Supply air filter 10. Compressor 11. Evaporator 12. Condenser 13. High pressure switch 14. Process valve 15. Cable entry 16. Electrical box 17. Condensate drain Ø15 18. Condensation tray 19. Supply air connection Ø100 at the back 20. Switch 21. Magnetic valve, defrosting 22. Thermo valve, condenser 23. Thermo valve, evaporater 24. Sensor, extract air 25. Sensor, fresh air 26. Sensor, supply air 27. Sensor, evaporator 28. Sensor, before evaporator 29. Preheater D 30. Sensor, exhaust air 31. Four ways valve Subject to technical modifications of Premium Preheat 250 CS/CL A datasheet

 Open the catalog to page 1
Premium Preheat 250 CS/CL A-2

Technical data Control panel Electrical connection without electrical reheater 1 x 230 V + N + PE, 10 A, 50 Hz Electrical connection with electrical reheater Max. 1.8 kW 1 x 230 V + N + PE, 16 A, 50 Hz Fans with direct drive motor R3G 190 Motor EC motor with integrated electronics Isolation class, fans B Speed Here the fan speed is adjustable in steps 0-1-2-3-4. Protection class, fans IP 44 Extended operation Here the timer to extended operation can be set between 0 to 9 hours. Fan speed (max. per fan) 3320 rpm Power consumption (max. per fan) 71 W Current consumption (max. per fan) 0.50 A Fan...

 Open the catalog to page 2
Premium Preheat 250 CS/CL A-3

Size (h x l x d) excl. connecting pieces: 600 x 1185 x 492 mm The capacity of Premium Preheat 250 CS/CL A varies with air volume and the outdoor air temperature. Cabinet construction Sandwich construction consisting of hot galvanized plate with 30 mm insulation. Powder coated white RAL 9010. Varmeydelse / heating capacity / Heizkapazität (W) Counter current heat exchanger Aluminium Condensation trays Stainless steel Condensate drain Stainless steel Ø15 mm (exterior) Supply air filter F7 Extract air filter M4 Luftmængde / air volume / Luftmenge 200 m3/h (Premium Preheat 250 CS A) 3000 2500 Frisklufttemp....

 Open the catalog to page 3
Premium Preheat 250 CS/CL A-4

The capacity lines are based on an average of the supply and extract mass flow in a unit. The red line in the chart indicates a total power consumption for both fans and the control of 1620 J/m³ (PHI). The curve shows the average external pressure, which is available at a given air volume. Total power consumption Power consumption (W) For both fans and control. Heat recovery rate Heat recovery rate, mass flow min = mout 01. Outdoor temp.: -12°C RH: 50% 02. Outdoor temp.: 4°C RH: 50% Heat recovery rate (%) Icing of the heat exchanger at low outdoor air temperatures has been left out of account....

 Open the catalog to page 4

All Genvex catalogs and technical brochures

  1. COMBI 185 BP

    6  Pages

  2. ECO 400 2022

    6  Pages

  3. ECO 375

    6  Pages

  4. ECO 360 R

    6  Pages

  5. ECO 275

    6  Pages

  6. ECO 190 XL

    6  Pages

  7. GES Energy M

    3  Pages

  8. GE Energy 2

    3  Pages

  9. GE Energy 3

    3  Pages

  10. GE Premium 3

    4  Pages

  11. Vanvex R

    3  Pages

  12. Vanvex RS

    3  Pages

  13. GS-4

    3  Pages

  14. GE Premium 2

    4  Pages

  15. GE Energy 1

    3  Pages

  16. GES Energy S

    3  Pages

Archived catalogs

  1. ECO 400 2019

    20  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.