1. Catalogs
  2. Genvex
  3. Premium Preheat 250 CL P

Premium Preheat 250 CL P
1 /4Pages

Premium Preheat 250 CL P

Premium Preheat 250 CL P
1 /4Pages

Catalog excerpts

Premium Preheat 250 CL P-1

Product description Premium Preheat 250 CL P is suitable in dwellings where a combination of heat recovery ventilation and supply of comfort heating or cooling with the supply air is desired. Before the fresh air is drawn into the house, heat is supplied to it in the counter current heat exchanger - heat recovered from the extract air. Then additional heat is supplied to the supply air by the heat pump and thereby it contributes to the home heating. If it is desired that cooling is supplied to the air instead, this is also possible. The supply air filter ensures that dirt and pollen is not brought into the house. Premium Preheat 250 CL P can deliver an air volume of up to appr. 275 m3/h at an external pressure of 100 Pa. Premium Preheat 250 CL P is an air-air heat recovery ventilation heat pump which is equipped with the following: A polystyrene counter current heat exchanger, a heat pump with cooling function, a preheater integrated in the heat pump, supply and extract air fans, F7 supply air filter, M4 extract air filter, and complete Optima 301 automatics with a control panel. Premium Preheat 250 CL P can be delivered with the following accessories: -- Electrical reheater for Ø160 mm duct Types Premium Preheat 250 CL P is available in a right- or left-handed version Premium Preheat 250 CL P (right-handed) Dimensions in mm. Lokation: 01. Fresh air Ø160 02. Exhaust air Ø160 03. Extract air Ø160 04. Supply air Ø160 05. Counter current heat exch. 06. Supply air fan 07. Extract air fan 08. Extract air filter 09. Supply air filter 10. Compressor 11. Evaporator 12. Condenser 13. High pressure switch 14. Process valve 15. Cable entry 16. Electrical box 17. Condensate drain Ø15 18. Condensation tray 19. Supply air connection Ø100 at the back 20. Switch 21. Magnetic valve, defrosting 22. Thermo valve, condenser 23. Thermo valve, evaporater 24. Sensor, extract air 25. Sensor, fresh air 26. Sensor, supply air 27. Sensor, evaporator 28. Sensor, before evaporator 29. Preheater D 30. Sensor, exhaust air 31. Four ways valve Subject to technical modifications of Premium Preheat 250 CL P datasheet

 Open the catalog to page 1
Premium Preheat 250 CL P-2

Technical data Control panel Electrical connection without electrical reheater 1 x 230 V + N + PE, 10 A, 50 Hz Electrical connection with electrical reheater Max. 1.8 kW 1 x 230 V + N + PE, 16 A, 50 Hz Fans with direct drive motor R3G 190 Motor EC motor with integrated electronics Isolation class, fans B Speed Here the fan speed is adjustable in steps 0-1-2-3-4. Protection class, fans IP 44 Extended operation Here the timer to extended operation can be set between 0 to 9 hours. Fan speed (max. per fan) 3320 rpm Power consumption (max. per fan) 71 W Reheater Here you can switch on and off the...

 Open the catalog to page 2
Premium Preheat 250 CL P-3

Size (h x l x d) excl. connecting pieces: 600 x 1185 x 492 mm The capacity of Premium Preheat 250 CL P varies with air volume and the outdoor air temperature. Cabinet construction Sandwich construction consisting of hot galvanized plate with 30 mm insulation. Powder coated white RAL 9010. Duct connection Ø160 mm (male end) with rubber sealing ring Ø100 mm (male end) supply air connection pieces (pointing backwards) Front cover Right and left cover with snap locks for filter service Counter current heat exchanger Polystyrene Condensate drain Stainless steel Ø15 mm (exterior) Supply air filter...

 Open the catalog to page 3
Premium Preheat 250 CL P-4

The capacity lines are based on an average of the supply and extract mass flow in a unit. The red line in the chart indicates a total power consumption for both fans and the control of 1620 J/m³ (PHI). The curve shows the average external pressure, which is available at a given air volume. Total power consumption For both fans and control. Heat recovery rate Icing of the heat exchanger at low outdoor air temperatures has been left out of account. 01. Outdoor temp.: -12°C RH: 50% 02. Outdoor temp.: 4°C RH: 50% Temperaturvirkningsgrad/ heat recovery rate/ Wärmerückgewinnung (%) Heat recovery rate,...

 Open the catalog to page 4

All Genvex catalogs and technical brochures

  1. COMBI 185 BP

    6  Pages

  2. ECO 400 2022

    6  Pages

  3. ECO 375

    6  Pages

  4. ECO 360 R

    6  Pages

  5. ECO 275

    6  Pages

  6. ECO 190 XL

    6  Pages

  7. GES Energy M

    3  Pages

  8. GE Energy 2

    3  Pages

  9. GE Energy 3

    3  Pages

  10. GE Premium 3

    4  Pages

  11. Vanvex R

    3  Pages

  12. Vanvex RS

    3  Pages

  13. GS-4

    3  Pages

  14. GE Premium 2

    4  Pages

  15. GE Energy 1

    3  Pages

  16. GES Energy S

    3  Pages

Archived catalogs

  1. ECO 400 2019

    20  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.